Microdutos de HDPE

24 vias 5/3.5mm Tubo Microduto PRadF

Zhejiang Oulu Automatic Equipment Co., Ltd. Short Description: Essential details Model Number:24ways 5/3.5mm DB Tube Bundle Type:Micro Duct & Tube Bundle Place of Origin:Wenzhou, China Brand Name:ANMASPC Use:FTTH Warranty Time:12months Network:None Color:Customized Material:HDPE Function:Install Cable Inner Diameter:3.5mm Outer Diameter:5mm Shape:Round PE:3.4mm Outer diameter:36.8mm (± 1.5mm) Tensile strength:≥ 6000N Storage temperature:-40°C ~ +70°C Supply Ability:1000000 Meter/Meters per Week FOB Price: US $0.5 - 9,999 / Piece Min.Order Quantity: 100 Piece/Pieces Supply Ability: 10000 Piece/Pieces per Month

CategoriaMicrodutos de HDPE

HDPE MICRODUCTS

24-way 5/3.5 mm HDPE microduct tube bundle

This 24-way DB HDPE microduct tube bundle is presented for direct-bury and indoor fiber-unit air-blowing projects.

The source states 5/3.5 mm inner ducts, 3.4 mm PE sheath, 36.8 mm bundle OD, at least 6,000 N tensile strength, 2,000 N crush load and a 920 mm minimum bend radius. Confirm route design and current batch evidence.

DETALHES TÉCNICOS

Dados de produto publicados

Physical and Mechanical Properties – Inner Micro duct 5/3.5mm
1
Aspeto visual
Inspecção visual
Superfície interior canelada e exterior lisa, isenta de bolhas, furos de contração, descamação, riscos e rugosidade.
2
Diâmetro exterior
ANMASPC
5.0mm ± 0.1mm
3
Espessura da parede
ANMASPC
0.75mm ± 0.10mm
4
Folga do diâmetro interior
Esferas de aço a soprar
A 3.0mm steel ball can be blown freely through the duct.
5
Ovalidade
ANMASPC
≤ 5%
6
Pressurização
5 minutes @15bar each duct
Sem danos nem fugas
7
Tendência fetichista
IEC 60794-1-2 Método E10
≤ 50mm
8
Resistência à tracção
Taxa de extensão
100mm/min
≥ 185N
9
Paixoneta
Comprimento da amostra: 250mm
Load: 550N
Duração da carga máx.: 1 min
Tempo de recuperação: 1 hora
Sem deformação residual > 15% nos diâmetros interior e exterior; deve passar no teste de folga do diâmetro interior.
10
Impacto
IEC 60794-1-2 Método E4
1.0 J Impact, recovery time 1 hour
Sem deformação residual > 15% nos diâmetros interior e exterior; deve passar no teste de folga do diâmetro interior.
11
reversão térmica
110℃ ~ 23℃, 1 hour
≤ 3%
12
Raio mín. de curvatura
60mm
Sem deformação residual > 15% nos diâmetros interior e exterior; deve passar no teste de folga do diâmetro interior.
13
Coeficiente de atrito
750mm Diameter, 450°loop, 5kg mass
≤ 0.1
14
Cor e impressão
Inspecção visual
Conforme especificação do cliente
Test
Characteristic
Test Method
Acceptance Criteria
Physical and Mechanical Properties – tube bundles
1
Aspeto visual
Visual inspection,
Outer sheath: Black
Superfície interior canelada e exterior lisa, isenta de bolhas, furos de contração, descamação, riscos e rugosidade.
2
Diâmetro exterior
ANMASPC
36.8mm (± 1.5mm)
3
Sheath Wall thickness
ANMASPC
3.40mm ± 0.20mm
4
Pressurização
5 minutes @15 bar each duct
Sem danos nem fugas
5
Resistência à tracção
Taxa de extensão
100mm/min
≥ 6000N
6
Paixoneta
Comprimento da amostra: 250mm
Load: 2000N
Duração da carga máx.: 1 min
Tempo de recuperação: 1 hora
Sem deformação residual > 15% nos diâmetros interior e exterior; deve passar no teste de folga do diâmetro interior.
7
Impacto
IEC 60794-1-2 Método E4
15.0J Impact, recovery time 1 hour
Sem deformação residual > 15% nos diâmetros interior e exterior; deve passar no teste de folga do diâmetro interior.
8
Raio mín. de curvatura
920mm
Sem deformação residual > 15% nos diâmetros interior e exterior; deve passar no teste de folga do diâmetro interior.
9
Cor e impressão
Inspecção visual
Orange or as per customer specification

GUIA DE SELEÇÃO

Selecting a 24-way 5/3.5 mm tube bundle

Use esses pontos de verificação para preparar uma consulta específica para o produto e resolver as questões de compatibilidade, testes e documentação antes de efetuar o pedido.

  1. Confirm capacityMatch 24 pathways to fiber count and spare capacity.
  2. Check duct fitConfirm 5/3.5 mm inner dimensions and cable-blowing clearance.
  3. Plan civil handlingUse 36.8 mm bundle OD and 920 mm minimum bend radius in the route plan.
  4. Request batch evidenceConfirm pressure, crush, impact, tensile, color, drum and quantity data.

Capacidade de OEM e projetos

Capacidade da empresa para o fornecimento de telecomunicações

A Oulu Automatic Equipment se apresenta como fornecedora de conectores de microtubos, sistemas de microtubos de HDPE, acessórios para sopro de cabos e acessórios pneumáticos para contratantes de telecomunicações, distribuidores e parceiros OEM.

Explorar as capacidades da empresa

Inspeção de qualidade para fornecimento de conector microducto de Oulu
Empacotamento de armazém para pedidos de conectores microducto de Oulu

Suporte de busca de fornecedores B2B

Suporte de compra B2B

The supplier’s Service page describes support from product consultation and customized solutions through production, delivery and after-sales. Include these details in a product enquiry:

  • Match 24 pathways to fiber count and spare capacity.
  • Quantidade alvo, mix de modelos ou tamanhos, necessidades de amostras e preferência quanto ao embalamento.
  • Desenhos, condições da rota, testes de pressão ou de vedação e documentos de conformidade.
  • O MOQ atual, o preço, o frete, o prazo de entrega da amostra e o prazo de produção devem ser confirmados na cotação.

O suporte ao nível da empresa e os termos comerciais devem ser reconfirmados para o produto e a encomenda selecionados.

Compartilhe dimensões, condições da rota e quantidades para uma cotação específica para o produto.Envie os requisitos do produto

SUPORTE PARA PROJETOS

Planeie a solução de microtubos ideal

Leia a revisão Serviço page for project context, then confirm exact fit, documents and commercial terms in the quotation.

Discuta sobre seu projeto

FAQ

Perguntas frequentes

What is a 24-way 5/3.5 mm microduct bundle used for?

It provides twenty-four HDPE pathways for direct-bury, FTTH and air-blown fiber routes.

What is the inner duct size?

The source states 5 mm outside diameter and 3.5 mm inside diameter.

What is the bundle outer diameter?

The published bundle outside diameter is 36.8 mm ±1.5 mm.

What tensile strength is stated?

The supplier states bundle tensile strength of at least 6,000 N. Confirm the test report for the selected batch.

What bend radius is listed?

A 920 mm minimum bend radius is stated for the bundle test conditions.

What should be included in a 24-way bundle enquiry?

Provide way count, OD/ID, route and burial conditions, bend limits, drum packing, quantity and documents.