Zhejiang Oulu Automatic Equipment Co., Ltd. Short Description: Model Number:4ways  DB Tube Bundle      Type:Micro Duct & Tube Bundle Place of Origin:Wenzhou, China Brand Name:ANMASPC Aging-resistant, anti corrosion of chemicals. HDPE Tube Bundle is convenient in construction, save time and the project cost. Waterproof, damp-proof, the telecommunications ducting can avoid the damage by rodent animals.     FOB Price: US $0.5 - 9,999 / Piece Min.Order Quantity: 100 Piece/Pieces Supply Ability: 10000 Piece/Pieces per Month

CategoriaMicrodutos de HDPE

CONECTORES MICRODUCT

4-way HDPE microduct tube bundle for fiber cable blowing

This 4-way HDPE microduct tube bundle is presented for fiber-optic cable blowing in telecom underground routes.

The captured source states 7.0 mm inner-duct OD, 1.2 mm wall, 16.4 mm × 16.4 mm bundle profile, 1,600 N bundle tensile strength, 2,000 N crush load and a 360 mm minimum bend radius. These are supplier-stated values; confirm the project drawing and batch tests.

DETALHES TÉCNICOS

Dados de produto publicados

Physical and Mechanical Properties – Inner Micro duct 
1
Aspeto visual
Inspecção visual
Superfície interior canelada e exterior lisa, isenta de bolhas, furos de contração, descamação, riscos e rugosidade.
2
Diâmetro exterior
ANMASPC
7.0mm ± 0.1mm
3
Espessura da parede
ANMASPC
1.20mm ± 0.10mm
4
Folga do diâmetro interior
Esferas de aço a soprar
A 3.0mm steel ball can be blown freely through the duct.
5
Ovalidade
ANMASPC
≤ 5%
6
Pressurização
5 minutes @16bar each duct
Sem danos nem fugas
7
Tendência fetichista
IEC 60794-1-2 Método E10
≤ 70mm
8
Resistência à tracção
Taxa de extensão
100mm/min
≥ 470N
9
Paixoneta
Comprimento da amostra: 250mm
Load: 1650N
Duração da carga máx.: 1 min
Tempo de recuperação: 1 hora
Sem deformação residual > 15% nos diâmetros interior e exterior; deve passar no teste de folga do diâmetro interior.
10
Impacto
IEC 60794-1-2 Método E4
1.0 J Impact, recovery time 1 hour
Sem deformação residual > 15% nos diâmetros interior e exterior; deve passar no teste de folga do diâmetro interior.
11
reversão térmica
110℃ ~ 23℃, 1 hour
≤ 3%
12
Raio mín. de curvatura
84mm
Sem deformação residual > 15% nos diâmetros interior e exterior; deve passar no teste de folga do diâmetro interior.
13
Coeficiente de atrito
750mm Diameter, 450°loop, 5kg mass
≤ 0.1
14
Cor e impressão
Inspecção visual
Conforme especificação do cliente
Test
Characteristic
Test Method
Acceptance Criteria
Physical and Mechanical Properties – tube bundles
1
Aspeto visual
Visual inspection,
Outer sheath: Black
Superfície interior canelada e exterior lisa, isenta de bolhas, furos de contração, descamação, riscos e rugosidade.
2
Diâmetro exterior
ANMASPC
16.4mm * 16.4mm (± 0.5mm)
3
Sheath Wall thickness
ANMASPC
1.20mm ± 0.20mm
4
Pressurização
5 minutos a 25 bar cada conduta
Sem danos nem fugas
5
Resistência à tracção
Taxa de extensão
100mm/min
≥ 1600N
6
Paixoneta
Comprimento da amostra: 250mm
Load: 2000N
Duração da carga máx.: 1 min
Tempo de recuperação: 1 hora
Sem deformação residual > 15% nos diâmetros interior e exterior; deve passar no teste de folga do diâmetro interior.
7
Impacto
IEC 60794-1-2 Método E4
5.0J Impact, recovery time 1 hour
Sem deformação residual > 15% nos diâmetros interior e exterior; deve passar no teste de folga do diâmetro interior.
8
Raio mín. de curvatura
360mm
Sem deformação residual > 15% nos diâmetros interior e exterior; deve passar no teste de folga do diâmetro interior.
9
Cor e impressão
Inspecção visual
Orange or as per customer specification

GUIA DE SELEÇÃO

Selecting a 4-way HDPE microduct bundle

Use esses pontos de verificação para preparar uma consulta específica para o produto e resolver as questões de compatibilidade, testes e documentação antes de efetuar o pedido.

  1. Confirm the pathwaysMatch four inner ducts to cable count and spare capacity.
  2. Check the clearanceConfirm the 7.0 mm duct and 3.0 mm blowing-ball clearance.
  3. Plan the routeUse the 16.4 mm bundle profile and 360 mm bend radius.
  4. Request batch evidenceConfirm pressure, tensile, crush, impact, color, drum and quantity documents.

Capacidade de OEM e projetos

Capacidade da empresa para o fornecimento de telecomunicações

A Oulu Automatic Equipment se apresenta como fornecedora de conectores de microtubos, sistemas de microtubos de HDPE, acessórios para sopro de cabos e acessórios pneumáticos para contratantes de telecomunicações, distribuidores e parceiros OEM.

Explorar as capacidades da empresa

Inspeção de qualidade para fornecimento de conector microducto de Oulu
Empacotamento de armazém para pedidos de conectores microducto de Oulu

Suporte de busca de fornecedores B2B

Suporte de compra B2B

The supplier’s Service page describes support from product consultation and customized solutions through production, delivery and after-sales. Include these details in a product enquiry:

  • Match four inner ducts to cable count and spare capacity.
  • Quantidade alvo, mix de modelos ou tamanhos, necessidades de amostras e preferência quanto ao embalamento.
  • Desenhos, condições da rota, testes de pressão ou de vedação e documentos de conformidade.
  • O MOQ atual, o preço, o frete, o prazo de entrega da amostra e o prazo de produção devem ser confirmados na cotação.

O suporte ao nível da empresa e os termos comerciais devem ser reconfirmados para o produto e a encomenda selecionados.

Compartilhe dimensões, condições da rota e quantidades para uma cotação específica para o produto.Envie os requisitos do produto

SUPORTE PARA PROJETOS

Planeie a solução de microtubos ideal

Leia a revisão Soluções de trajeto de microtubos e Serviço páginas com informações sobre o contexto do projeto, depois confirma a adequação exata, documentos e condições comerciais na cotação.

Discuta sobre seu projeto

FAQ

Perguntas frequentes

What is a 4-way HDPE microduct bundle used for?

It provides four HDPE pathways for fiber-optic cable blowing in telecom routes.

What inner duct size is stated?

The source states 7.0 mm inner-duct outside diameter with a 1.2 mm wall.

What is the bundle profile?

The published bundle profile is 16.4 mm × 16.4 mm ±0.5 mm.

What tensile strength is stated?

The source states inner tensile strength of at least 470 N and bundle tensile strength of at least 1,600 N.

What bend radius is listed?

A 360 mm minimum bundle bend radius is stated.

What should a bundle enquiry include?

Provide way count, duct dimensions, route length, bend limits, drum packing, quantity and test documents.