Zhejiang Oulu Automatic Equipment Co., Ltd. Short Description: Essential details Model Number:24ways 5/3.5mm DB Tube Bundle Type:Micro Duct & Tube Bundle Place of Origin:Wenzhou, China Brand Name:ANMASPC Use:FTTH Warranty Time:12months Network:None Color:Customized Material:HDPE Function:Install Cable Inner Diameter:3.5mm Outer Diameter:5mm Shape:Round PE:3.4mm Outer diameter:36.8mm (± 1.5mm) Tensile strength:≥ 6000N Storage temperature:-40°C ~ +70°C Supply Ability:1000000 Meter/Meters per Week FOB Price: US $0.5 - 9,999 / Piece Min.Order Quantity: 100 Piece/Pieces Supply Ability: 10000 Piece/Pieces per Month

CategoríaMicroductos de HDPE

HDPE MICRODUCTS

24-way 5/3.5 mm HDPE microduct tube bundle

This 24-way DB HDPE microduct tube bundle is presented for direct-bury and indoor fiber-unit air-blowing projects.

The source states 5/3.5 mm inner ducts, 3.4 mm PE sheath, 36.8 mm bundle OD, at least 6,000 N tensile strength, 2,000 N crush load and a 920 mm minimum bend radius. Confirm route design and current batch evidence.

TECHNICAL DETAILS

Published product facts

Physical and Mechanical Properties – Inner Micro duct 5/3.5mm
1
Apariencia visual
Inspección visual
Superficie interior acanalada y exterior lisa, libre de ampollas, sopladuras, descamación, arañazos y rugosidad.
2
Diámetro exterior
ANMASPC
5.0mm ± 0.1mm
3
Espesor de pared
ANMASPC
0.75mm ± 0.10mm
4
Holgura del diámetro interior
Bola de acero soplando
Una bola de acero de 3,0 mm se puede soplar libremente a través del conducto.
5
Ovalidad
ANMASPC
≤ 5%
6
Presurización
5 minutes @15bar each duct
Sin daños ni fugas
7
Parafilias
IEC 60794-1-2 Método E10
≤ 50mm
8
Resistencia a la tracción
Velocidad de extensión:
100 mm/min
≥ 185N
9
Crush
Longitud de la muestra: 250 mm
Load: 550N
Duración de la carga máx.: 1 min
Tiempo de recuperación: 1 hora
No debe haber deformación residual > 15% en el diámetro interior ni en el exterior; debe superar la prueba de holgura del diámetro interior.
10
Impacto
IEC 60794-1-2 Método E4
Impacto de 1.0 J, tiempo de recuperación de 1 hora
No debe haber deformación residual > 15% en el diámetro interior ni en el exterior; debe superar la prueba de holgura del diámetro interior.
11
Reversión térmica
110℃ ~ 23℃, 1 hour
≤ 3%
12
Radio de curvatura mín.
60mm
No debe haber deformación residual > 15% en el diámetro interior ni en el exterior; debe superar la prueba de holgura del diámetro interior.
13
Coeficiente de fricción
750mm Diameter, 450°loop, 5kg mass
≤ 0.1
14
Color e impresión
Inspección visual
Según la especificación del cliente
Prueba
Characteristic
Test Method
Acceptance Criteria
Physical and Mechanical Properties – tube bundles
1
Apariencia visual
Visual inspection,
Outer sheath: Black
Superficie interior acanalada y exterior lisa, libre de ampollas, sopladuras, descamación, arañazos y rugosidad.
2
Diámetro exterior
ANMASPC
36.8mm (± 1.5mm)
3
Sheath Wall thickness
ANMASPC
3.40mm ± 0.20mm
4
Presurización
5 minutes @15 bar each duct
Sin daños ni fugas
5
Resistencia a la tracción
Velocidad de extensión:
100 mm/min
≥ 6000N
6
Crush
Longitud de la muestra: 250 mm
Load: 2000N
Duración de la carga máx.: 1 min
Tiempo de recuperación: 1 hora
No debe haber deformación residual > 15% en el diámetro interior ni en el exterior; debe superar la prueba de holgura del diámetro interior.
7
Impacto
IEC 60794-1-2 Método E4
15.0J Impact, recovery time 1 hour
No debe haber deformación residual > 15% en el diámetro interior ni en el exterior; debe superar la prueba de holgura del diámetro interior.
8
Radio de curvatura mín.
920mm
No debe haber deformación residual > 15% en el diámetro interior ni en el exterior; debe superar la prueba de holgura del diámetro interior.
9
Color e impresión
Inspección visual
Orange or as per customer specification

SELECTION GUIDE

Selecting a 24-way 5/3.5 mm tube bundle

Use these checkpoints to prepare a product-specific enquiry and close the fit, test and documentation questions before ordering.

  1. Confirm capacityMatch 24 pathways to fiber count and spare capacity.
  2. Check duct fitConfirm 5/3.5 mm inner dimensions and cable-blowing clearance.
  3. Plan civil handlingUse 36.8 mm bundle OD and 920 mm minimum bend radius in the route plan.
  4. Request batch evidenceConfirm pressure, crush, impact, tensile, color, drum and quantity data.

OEM & PROJECT CAPABILITY

Company capability for telecom supply

Oulu Automatic Equipment presents itself as a supplier of microduct connectors, HDPE microduct systems, cable blowing accessories and pneumatic fittings for telecom contractors, distributors and OEM partners.

Explore company capabilities

Quality inspection for Oulu microduct connector supply
Warehouse packing for Oulu microduct connector orders

B2B SOURCING SUPPORT

B2B purchasing support

The supplier’s Service page describes support from product consultation and customized solutions through production, delivery and after-sales. Include these details in a product enquiry:

  • Match 24 pathways to fiber count and spare capacity.
  • Target quantity, model or size mix, sample needs and packing preference.
  • Drawings, route conditions, pressure or sealing tests and compliance documents.
  • Current MOQ, price, freight, sample timing and production timing to be confirmed in the quotation.

Company-level support and commercial terms should be reconfirmed for the selected product and order.

Share dimensions, route conditions and quantities for a product-specific quotation.Send product requirements

PROJECT SUPPORT

Plan the right microduct solution

Review the Servicio page for project context, then confirm exact fit, documents and commercial terms in the quotation.

Discuss your project

Preguntas frecuentes

Preguntas frecuentes

What is a 24-way 5/3.5 mm microduct bundle used for?

It provides twenty-four HDPE pathways for direct-bury, FTTH and air-blown fiber routes.

What is the inner duct size?

The source states 5 mm outside diameter and 3.5 mm inside diameter.

What is the bundle outer diameter?

The published bundle outside diameter is 36.8 mm ±1.5 mm.

What tensile strength is stated?

The supplier states bundle tensile strength of at least 6,000 N. Confirm the test report for the selected batch.

What bend radius is listed?

A 920 mm minimum bend radius is stated for the bundle test conditions.

What should be included in a 24-way bundle enquiry?

Provide way count, OD/ID, route and burial conditions, bend limits, drum packing, quantity and documents.