HDPE микро хоолой

24 арга 5/3.5 мм HDPE микро хоолойн хоолой

Zhejiang Oulu Automatic Equipment Co., Ltd. Short Description: Essential details Model Number:24ways 5/3.5mm DB Tube Bundle Type:Micro Duct & Tube Bundle Place of Origin:Wenzhou, China Brand Name:ANMASPC Use:FTTH Warranty Time:12months Network:None Color:Customized Material:HDPE Function:Install Cable Inner Diameter:3.5mm Outer Diameter:5mm Shape:Round PE:3.4mm Outer diameter:36.8mm (± 1.5mm) Tensile strength:≥ 6000N Storage temperature:-40°C ~ +70°C Supply Ability:1000000 Meter/Meters per Week FOB Price: US $0.5 - 9,999 / Piece Min.Order Quantity: 100 Piece/Pieces Supply Ability: 10000 Piece/Pieces per Month

АнгилалHDPE микро хоолой

HDPE MICRODUCTS

24-way 5/3.5 mm HDPE microduct tube bundle

This 24-way DB HDPE microduct tube bundle is presented for direct-bury and indoor fiber-unit air-blowing projects.

The source states 5/3.5 mm inner ducts, 3.4 mm PE sheath, 36.8 mm bundle OD, at least 6,000 N tensile strength, 2,000 N crush load and a 920 mm minimum bend radius. Confirm route design and current batch evidence.

TECHNICAL DETAILS

Published product facts

Physical and Mechanical Properties – Inner Micro duct 5/3.5mm
1
Гадна төрх
Харааны үзлэг
Дотор талдаа хонхойсон, гадна талдаа гөлгөр гадаргуутай, бөмбөлөг толбо, агшилтын нүх, хуулран хагарсан хэсэг, зураас болон ширүүн байдлаас ангид.
2
Гадна диаметр
АНМАСПС
5.0mm ± 0.1mm
3
Ханын зузаан
АНМАСПС
0.75mm ± 0.10mm
4
Дотор диаметрийн зөрүү
Газрын тосоор дүүргэсэн ган бөмбөг
3.0 мм-ийн ган бөмбөгийг хоолойгоор чөлөөтэй үлээж болно.
5
Эллипст байдал
АНМАСПС
≤ 5%
6
Шахалтжуулалт
5 minutes @15bar each duct
Эвдрэл, гоожилтгүй
7
Кинк
IEC 60794-1-2 арга E10
≤ 50mm
8
Суналтын бат бэх
Тэлэх хурд:
100 мм/мин
≥ 185N
9
Бүтлэх
Сорилтын урт: 250 мм
Load: 550N
Хамгийн их ачааллын үргэлжлэх хугацаа: 1 минут
Сэргэх хугацаа: 1 цаг
Дотор болон гадна диаметрийн үлдэгдэл деформаци 15%-ээс ихгүй байх ёстой, дотор диаметрийн завсрын шалгалтад тэнцэх ёстой.
10
Нөлөө
IEC 60794-1-2 арга E4
1.0 J цохилт, сэргэх хугацаа 1 цаг
Дотор болон гадна диаметрийн үлдэгдэл деформаци 15%-ээс ихгүй байх ёстой, дотор диаметрийн завсрын шалгалтад тэнцэх ёстой.
11
Дулааны эргэлт
110℃ ~ 23℃, 1 hour
≤ 3%
12
Минимал нугалах радиус
60mm
Дотор болон гадна диаметрийн үлдэгдэл деформаци 15%-ээс ихгүй байх ёстой, дотор диаметрийн завсрын шалгалтад тэнцэх ёстой.
13
Үрэлтийн коэффициент
750mm Diameter, 450°loop, 5kg mass
≤ 0.1
14
Өнгө ба хэвлэл
Харааны үзлэг
Хэрэглэгчийн тодорхойлолтын дагуу
Шалгалт
Онцлог
Шалгалтын арга
Хүлээн авах шалгуур
Physical and Mechanical Properties – tube bundles
1
Гадна төрх
Харааны үзлэг,
Гадна бүрээс: Хар
Дотор талдаа хонхойсон, гадна талдаа гөлгөр гадаргуутай, бөмбөлөг толбо, агшилтын нүх, хуулран хагарсан хэсэг, зураас болон ширүүн байдлаас ангид.
2
Гадна диаметр
АНМАСПС
36.8mm (± 1.5mm)
3
Хальс ханы зузаан
АНМАСПС
3.40mm ± 0.20mm
4
Шахалтжуулалт
5 minutes @15 bar each duct
Эвдрэл, гоожилтгүй
5
Суналтын бат бэх
Тэлэх хурд:
100 мм/мин
≥ 6000N
6
Бүтлэх
Сорилтын урт: 250 мм
Ачаа: 2000 Н
Хамгийн их ачааллын үргэлжлэх хугацаа: 1 минут
Сэргэх хугацаа: 1 цаг
Дотор болон гадна диаметрийн үлдэгдэл деформаци 15%-ээс ихгүй байх ёстой, дотор диаметрийн завсрын шалгалтад тэнцэх ёстой.
7
Нөлөө
IEC 60794-1-2 арга E4
15.0J Impact, recovery time 1 hour
Дотор болон гадна диаметрийн үлдэгдэл деформаци 15%-ээс ихгүй байх ёстой, дотор диаметрийн завсрын шалгалтад тэнцэх ёстой.
8
Минимал нугалах радиус
920mm
Дотор болон гадна диаметрийн үлдэгдэл деформаци 15%-ээс ихгүй байх ёстой, дотор диаметрийн завсрын шалгалтад тэнцэх ёстой.
9
Өнгө ба хэвлэл
Харааны үзлэг
Улаан лооль эсвэл захиалагчийн заасан дагуу

SELECTION GUIDE

Selecting a 24-way 5/3.5 mm tube bundle

Use these checkpoints to prepare a product-specific enquiry and close the fit, test and documentation questions before ordering.

  1. Confirm capacityMatch 24 pathways to fiber count and spare capacity.
  2. Check duct fitConfirm 5/3.5 mm inner dimensions and cable-blowing clearance.
  3. Plan civil handlingUse 36.8 mm bundle OD and 920 mm minimum bend radius in the route plan.
  4. Request batch evidenceConfirm pressure, crush, impact, tensile, color, drum and quantity data.

OEM & PROJECT CAPABILITY

Company capability for telecom supply

Oulu Automatic Equipment presents itself as a supplier of microduct connectors, HDPE microduct systems, cable blowing accessories and pneumatic fittings for telecom contractors, distributors and OEM partners.

Explore company capabilities

Quality inspection for Oulu microduct connector supply
Warehouse packing for Oulu microduct connector orders

B2B SOURCING SUPPORT

B2B purchasing support

The supplier’s Service page describes support from product consultation and customized solutions through production, delivery and after-sales. Include these details in a product enquiry:

  • Match 24 pathways to fiber count and spare capacity.
  • Target quantity, model or size mix, sample needs and packing preference.
  • Drawings, route conditions, pressure or sealing tests and compliance documents.
  • Current MOQ, price, freight, sample timing and production timing to be confirmed in the quotation.

Company-level support and commercial terms should be reconfirmed for the selected product and order.

Share dimensions, route conditions and quantities for a product-specific quotation.Send product requirements

PROJECT SUPPORT

Plan the right microduct solution

Review the Үйлчилгээ page for project context, then confirm exact fit, documents and commercial terms in the quotation.

Discuss your project

Түгээмэл асуултууд

Олонтаа асуугддаг асуултууд

What is a 24-way 5/3.5 mm microduct bundle used for?

It provides twenty-four HDPE pathways for direct-bury, FTTH and air-blown fiber routes.

What is the inner duct size?

The source states 5 mm outside diameter and 3.5 mm inside diameter.

What is the bundle outer diameter?

The published bundle outside diameter is 36.8 mm ±1.5 mm.

What tensile strength is stated?

The supplier states bundle tensile strength of at least 6,000 N. Confirm the test report for the selected batch.

What bend radius is listed?

A 920 mm minimum bend radius is stated for the bundle test conditions.

What should be included in a 24-way bundle enquiry?

Provide way count, OD/ID, route and burial conditions, bend limits, drum packing, quantity and documents.