업계 인사이트

뉴스 및 블로그

마이크로덕트, 광케이블 설치 및 공압 연결 전문가를 위한 업계 뉴스, 기술 가이드 및 실무 프로젝트 인사이트.

최신 기사

기사

워터 블록 마이크로덕트 커넥터 설명: 언제 씰을 활성화해야 합니까?

워터 블록 마이크로덕트 커넥터 설명: 언제 씰을 활성화해야 합니까?

A cable route can pass a blowing check yet still leave a path for water into a building. For contractors selecting a water-block connector, the difficult question is not simply whether the fitting grips the duct. It is whether the supplied seal matches the installed cable, whether its assembly state is correct, and which migration path the connector actually closes. Assuming every waterblock needs…

상세보기
가스 블록 마이크로덕트 커넥터: 마이크로덕트 입구에서 가스와 물을 차단하는 방법

가스 블록 마이크로덕트 커넥터: 마이크로덕트 입구에서 가스와 물을 차단하는 방법

A microduct connection that holds air during cable blowing can still leave a migration path around the installed cable. At a building or optical distribution frame entry, that difference changes the purchasing decision: does the route need a duct joint, an occupied-duct seal, or a separate penetration system? Choosing by nominal duct size or a single pressure figure can leave those functions unresolved and…

상세보기
HDPE 및 FTTx 덕트 네트워크를 위한 직매형 마이크로덕트 커넥터(Direct buried microduct connector) 사양 지정 방법

HDPE 및 FTTx 덕트 네트워크를 위한 직매형 마이크로덕트 커넥터(Direct buried microduct connector) 사양 지정 방법

A connector that grips a microduct in a chamber is not automatically suitable for placing directly in soil. For contractors and buyers, the difficult decision is whether the ordered fitting and the duct around it are both intended for the proposed buried route. A familiar nominal size, an ingress-protection claim, or a successful empty-duct pressure check cannot answer every part of that question. Once…

상세보기
마이크로덕트 푸시핏 커넥터가 필요하십니까? 규격, 압력 정격 및 용도를 비교해 보세요.

마이크로덕트 푸시핏 커넥터가 필요하십니까? 규격, 압력 정격 및 용도를 비교해 보세요.

A connector ordered by nominal duct size can still be unsuitable for the assembled route. Procurement teams need to compare the actual outside diameter, the bore available for the cable, the wall construction and the installation environment, not just a catalogue pressure column. A tube may be retained before it is fully seated, while two ducts with the same outside diameter can have different…

상세보기
마이크로덕트 엔드 캡 트러블슈팅: 캡이 느슨해지는 이유와 해결 방법

마이크로덕트 엔드 캡 트러블슈팅: 캡이 느슨해지는 이유와 해결 방법

A microduct end cap that comes loose creates two questions for the maintenance team: has the fitting lost its grip, or has the duct stopped sealing? Those faults can occur together, but treating them as the same problem encourages repeated reseating without finding the cause. A cap can grip a tube before the tube reaches its sealing position; conversely, visible water around a cap…

상세보기
엔드 스톱 마이크로덕트 커넥터 대 가스 블록 커넥터: 어떤 클로저를 사용해야 할까요?

엔드 스톱 마이크로덕트 커넥터 대 가스 블록 커넥터: 어떤 클로저를 사용해야 할까요?

A spare microduct and a duct carrying cable can need protection at the same chamber, but they do not present the same sealing interface. Ordering an end stop and a gas block simply because both are described as closures overlooks that difference. The end stop closes a vacant bore; an occupied duct leaves a space around the cable that needs a compatible cable seal.…

상세보기
How to Install a Microduct End Stops Without Damaging the Microduct

How to Install a Microduct End Stops Without Damaging the Microduct

When a field technician in Denver, USA, capped an open microduct before a storm, the cap later stuck to a nicked tube and pulled the edge outward. This illustrative scenario is not a customer case. Measuring the duct OD, cutting back to undamaged HDPE and using the supplied clip avoided damage while keeping the route protected. The short answer is: A Microduct End Stops…

상세보기
HDPE 압축 피팅 설치: 안정적이고 기밀한 실링을 위한 7단계

HDPE 압축 피팅 설치: 안정적이고 기밀한 실링을 위한 7단계

When a network contractor in Bristol, UK, connected a short repair section, air escaped at the first bend. This illustrative scenario is not a customer case: the root cause was a diagonal cut and a missing insertion mark, not a mysterious fitting defect. Seven repeatable steps turned the repair into a documented, airtight joint. The short answer is: Reliable HDPE compression fittings depend on…

상세보기
Reducing Microduct Connector Explained: A Practical Guide for Fiber Installers

Reducing Microduct Connector Explained: A Practical Guide for Fiber Installers

When a fiber installer in Oulu, Finland, switched a 12 mm feeder duct to a 10 mm branch, the first pressure check failed within minutes. This is an illustrative scenario, not a claimed customer case: the reversal came after measuring both outside diameters (OD), cleaning the cuts and selecting a reducer matched to each wall thickness. The connector was not “bad”; the transition specification…

상세보기