業界インサイト

ニュース&ブログ

マイクロダクト、ファイバー敷設、空圧接続のプロフェッショナルに向けた業界ニュース、技術ガイド、実践的なプロジェクトインサイト.

最新の記事

記事

How to Install a Microduct End Stops Without Damaging the Microduct

How to Install a Microduct End Stops Without Damaging the Microduct

When a field technician in Denver, USA, capped an open microduct before a storm, the cap later stuck to a nicked tube and pulled the edge outward. This illustrative scenario is not a customer case. Measuring the duct OD, cutting back to undamaged HDPE and using the supplied clip avoided damage while keeping the route protected. The short answer is: A Microduct End Stops…

詳細を見る
HDPE compression fittings Installation: 7 Steps for a Reliable, Airtight Seal

HDPE compression fittings Installation: 7 Steps for a Reliable, Airtight Seal

When a network contractor in Bristol, UK, connected a short repair section, air escaped at the first bend. This illustrative scenario is not a customer case: the root cause was a diagonal cut and a missing insertion mark, not a mysterious fitting defect. Seven repeatable steps turned the repair into a documented, airtight joint. The short answer is: Reliable HDPE compression fittings depend on…

詳細を見る
Reducing Microduct Connector Explained: A Practical Guide for Fiber Installers

Reducing Microduct Connector Explained: A Practical Guide for Fiber Installers

When a fiber installer in Oulu, Finland, switched a 12 mm feeder duct to a 10 mm branch, the first pressure check failed within minutes. This is an illustrative scenario, not a claimed customer case: the reversal came after measuring both outside diameters (OD), cleaning the cuts and selecting a reducer matched to each wall thickness. The connector was not “bad”; the transition specification…

詳細を見る
Microduct Reducer Connector: How to Choose the Right Size and Stop Air Leaks

Microduct Reducer Connector: How to Choose the Right Size and Stop Air Leaks

When a fiber-installation supervisor in Manchester encountered a falling air-pressure reading during a last-mile blow, she first blamed the compressor. The crew isolated the handhole and measured both HDPE ducts; a nominally similar straight fitting crossed two different outside diameters. A correctly sized reducer stopped the leak, showing the root cause was selection and installation control, not simply a bad fitting. The short answer…

詳細を見る
How to Specify Microduct Connector Reducer for HDPE and FTTx Duct Networks

How to Specify Microduct Connector Reducer for HDPE and FTTx Duct Networks

When a network contractor in Manchester encountered repeated air loss on a new FTTx spur, the crew first blamed the blowing unit and replaced a connector at the cabinet. The leak reappeared as soon as the next cable run began. A review of the as-built notes showed that the reducer had been selected by nominal duct size, while its actual outside-diameter range and prepared…

詳細を見る
HDPEマイクロダクトコネクター用カプラーが必要ですか?サイズ、定格圧力、および用途の比較

HDPEマイクロダクトコネクター用カプラーが必要ですか?サイズ、定格圧力、および用途の比較

マンチェスターの通信工事の職長が、光ファイバーのエア吹込作業を控えて道路脇のキャビネットで12/10mmのダクトを接続した際、コンプレッサーの圧力が低下し、ケーブルは次のアクセスポイントの手前で止まってしまった。カプラーは無傷に見えたが、突然の不具合の原因は、12mmのストレート継ぎ手の片側に10mmのダクトが押し込まれていたことに加え、内部に隠れていた…

詳細を見る
マイクロダクト継手のトラブルシューティング:光ファイバの吹き込み前に漏れを修理する

マイクロダクト継手のトラブルシューティング:光ファイバの吹き込み前に漏れを修理する

リーズの光ファイバー敷設監督が、送気工事用のFTTxルートの準備中にシューという音のする継ぎ手を発見した際、作業員はまずコンプレッサーの設定圧力を上げましたが、圧力計の数値は依然として急激に低下し、ケーブルは前進しませんでした。目に見える不具合は不良継ぎ手のように見えましたが、ノギスによる測定と切断面の綿密な観察により、真の原因が明らかになりました。それは、公称上適合しているはずの…

詳細を見る
屋外用マイクロダクトカプラー:材質、試験、および耐用年数

屋外用マイクロダクトカプラー:材質、試験、および耐用年数

ブリスベンの光ファイバー施工現場の親方が、街路キャビネットの横で2つの12/10mm管を接続し、簡単な引き抜きテストを行ってからその区間のケーブル吹込み作業を許可した。数分後、継ぎ手からのシューという音と停止したケーブルによって、その失敗が明らかになった。最初は、屋外用カプラーが暑さで破損したのだろうと推測されたが、点検の結果、斜めに切断されたHDPE管、挿入不足、そして…

詳細を見る