Microduct Connectors

Microduct Endcap CO CAPS full sizes wholesale

Zhejiang Oulu Automatic Equipment Co., Ltd. Short Description: DESCRIPTION: Standard transparent end caps, which are used to terminate open ended Tubes to avoid air leakage, water or other material ingress. End caps are preassembled with security clips. MAIN FEATURES: ① Safety clips included ②  Push-ft technology ③  Working Pressure: max. 25 bars                        

CategoryMicroduct Connectors

Full-size microduct endcap range for telecom procurement

This microduct endcap family is presented for terminating open-ended telecom tubes and helping limit air leakage, water and material ingress.

Supplier data lists transparent push-fit bodies, preassembled safety clips, a maximum working pressure of 25 bar and FPF sizes from 3–20 mm outside diameter.

Key details

                        Microduct Endcap CO CAPS full sizes=                       Microduct Endcap CO CAPS full wholesale detail image 6

Componants

1 Collet POM
2 Locking Clip POM
3 Cartridge ZINK ALLOY
4 Lock Claw SUS301/304
5 Support Ring POM
6 Seal Ring TEP
7 Body PC2807

Fit Tube

Pipe material HDPE、PE、Nylon、Polyurethane
Outer diameter of pipe Φ3,Φ4,Φ5,Φ6,Φ7,Φ8,Φ10,Φ12,Φ16,Φ18,Φ20

Technical Parameter

Working with fluids Air
Tightness 0.15~0.8MPa No Leak
Pull test 400N
Proof pressure 2.5MPa
Operating pressure range 0~1.6MPa
Ambient temperature and fluid temperature -40~60℃
Installation Temperature   -10℃/+50℃
Recommended Blowing Temperature   -15℃/+35℃
Degree of protection IP68
UV-resistant grade F1
Insertion force 50N max(5kg)
Lifespan: 25 years
StAndards: EN 50411-2-8

Specifications And Dimensions

ANMASPC Code OD/ID
FPF3 3
FPF4 4
FPF5 5
FPF6 6
FPF7 7
FPF8 8
FPF10 10
FPF12 12
FPF14 14
FPF16 16
FPF18 18
FPF20 20

Building a multi-size microduct endcap order

Use these checkpoints to prepare a product-specific enquiry and avoid selecting by a general trade name alone.

  1. List every tube size: Provide measured outside diameters and required quantities by FPF code rather than asking for an unspecified mixed range.
  2. Separate route conditions: Identify any sizes used in different chambers, routes or pressure conditions.
  3. Confirm fit and test data: Request dimensional drawings and applicable sealing or pressure information for the selected versions.
  4. Confirm commercial terms: Ask for current MOQ, mixed-size packing, sample availability, lead time and export documents in the quotation.

OEM & PROJECT CAPABILITY

Company capability for telecom supply

Oulu Automatic Equipment presents itself as a supplier of microduct connectors, HDPE microduct systems, cable blowing accessories and pneumatic fittings for telecom contractors, distributors and OEM partners.

Explore company capabilities

Engineering review for Oulu microduct connector supply

B2B SOURCING SUPPORT

B2B purchasing support

The supplier’s Service page describes support from product consultation and customized solutions through production, delivery and after-sales. For a product-specific enquiry, include:

  • Provide measured outside diameters and required quantities by FPF code rather than asking for an unspecified mixed range.
  • Target quantity by size or model, sample needs, mixed specifications and packing preference.
  • Project drawings, pressure or sealing requirements, and required compliance or export documents.
  • Current MOQ, payment, freight, sample timing and production timing to be confirmed in the quotation.

Company-level service statements and commercial terms should be reconfirmed for the selected product and order.

Warehouse packing for Oulu microduct connector orders
Share dimensions, route conditions and quantities for a product-specific quotation.
Send product requirements

PROJECT SUPPORT

Plan the microduct connection or sealing point

Review the microduct route solutions page and the supplier’s Service page for project-support context. Confirm the exact product fit, documents and commercial terms in the quotation.

Discuss your project

FAQ

What is a microduct endcap used for?

It closes an open-ended telecom tube and is described as helping limit air leakage and water or material ingress.

What are the standard sizes of microducts?

Network sizes vary. This endcap family publishes FPF3–FPF20 versions for 3–20 mm outside diameter.

Can I order multiple microduct endcap sizes together?

Mixed-size supply may be discussed, but current MOQ, packing and commercial terms should be confirmed in the quotation.

How do I select an FPF endcap code?

Match the measured tube outside diameter to the published FPF size and request the dimensional drawing for final confirmation.

What pressure can the transparent endcap handle?

The supplier publishes a maximum working pressure of 25 bar. Confirm the test method and actual project condition before use.

What details are needed for a wholesale microduct endcap enquiry?

Provide quantities by size, tube material, application, sealing requirement, packing preference, destination and document needs.