HDPE Microducts

7 Ways 12/10 mm DB HDPE Tube

Zhejiang Oulu Automatic Equipment Co., Ltd. Short Description: Essential details Model Number:7 Ways 12/10mm DB Tube Bundle Type:Tube bundle Place of Origin:Shanghai, China Brand Name:ANMASPC Use:FTTH Warranty Time:12months Network:None Sub duct Inner diameter:10mm Sub duct outer diameter:12mm PE Sheath:3.4mm Outer Diameter::42.8mm (±1.1mm) Melt flow index:0.1 ~ 0.4 g/10 minutes Density:Min. 0.940 g/cm3 Tensile strength at yield:Min. 20MPa Elongation at the break:Min 350% Environmental stress crack resist (F50):Min. 96 hours Storage temperature:-40°C ~ +70°C Supply Ability:1000000 Piece/Pieces per Day       FOB Price: US $0.5 - 9,999 / Piece Min.Order Quantity: 100 Piece/Pieces Supply Ability: 10000 Piece/Pieces per Month

CategoryHDPE Microducts

MICRODUCT CONNECTORS

7-way 12/10 mm direct-buried HDPE microduct tube bundle

This 7-way 12/10 mm DB HDPE microduct tube bundle is presented for outdoor direct-bury FTTH and air-blown cable routes.

The source states 12 mm OD, 10 mm ID, 3.4 mm PE sheath, 42.8 mm bundle OD ±1.1 mm, bundle tensile 6,800 N and 2,000 N crush load. Confirm route design and batch tests.

TECHNICAL DETAILS

Published product facts

Pos.
Mechanical performance
Test conditions
Performance
Standard
1
Tensile strength
at yield
Rate of extension:
100mm/min
≥620N
IEC 60794-1-2
Method E1
2
Crush
Sample length: 250mm
Load: 380N
Duration of Max. load: 1 minutes
Recovery time: 1 hour
The outer and inner diameter shall show, under visual examination without damage and no reduction of diameter greater than 15%.
IEC 60794-1-2
Method E3
3
Kink
≤120mm
-
IEC 60794-1-2
Method E10
4
Impact
Striking surface radius: 10mm
Impact Energy: 1J
Number of impact: 3 times
Recovery time: 1 hour
Under visual examination, there shall be no damage to the micro duct.
IEC 60794-1-2
Method E4
5
Bend radius
Number of turns: 5
Mandrel diameter:144mm.
Mumber of cycles: 3
The outer and inner diameter shall show, under visual examination without damage and no reduction of diameter greater than 15%.
IEC 60794-1-2
Method E11
Pos.
Item
Specification
1
Appearance
Smooth outer wall (UV-stabilized) without visible impurities; well-proportioned color, no bubbles or cracks; with defined markings
on outer wall.
2
Tensile strength
Use Pull socks to tension a sample in accordance with table below:
Sample length: 1m
Tensile speed: 20mm/min
Load: 6800N
Duration of the tension: 5 min.
No visual damage or residual deformation greater than 15% of the duct assembly outer diameter.
3
Crush Resistance
A 250mm sample after 1 minute load time and 1 hour recovery time. Load (plate) shall be 2000N. The imprint of the plate on the
sheath is not considered as mechanical damage.
No visual damage or residual deformation greater than 15% of the duct assembly outer diameter.
4
Impact
Striking surface radius shall be 10mm and impact energy 10J. Recovery time shall be one out. The imprint of the striking surface
on the microduct is not considered as mechanical damage.
No visual damage or residual deformation greater than 15% of the duct assembly outer diameter.
5
Bend
Diameter of mandrel shall be 40X OD of sample, 4 turns, 3 cycles.
No visual damage or residual deformation greater than 15% of the duct assembly outer diameter.

SELECTION GUIDE

Selecting a 7-way 12/10 mm DB bundle

Use these checkpoints to prepare a product-specific enquiry and close the fit, test and documentation questions before ordering.

  1. Confirm capacityMatch seven 12/10 mm pathways to the fiber route.
  2. Check the cable clearanceConfirm 10 mm ID and the blowing equipment.
  3. Plan direct burialUse the 42.8 mm bundle OD, sheath and bend requirements.
  4. Request batch evidenceConfirm tensile, crush, impact, pressure, color, drum and quantity documents.

OEM & PROJECT CAPABILITY

Company capability for telecom supply

Oulu Automatic Equipment presents itself as a supplier of microduct connectors, HDPE microduct systems, cable blowing accessories and pneumatic fittings for telecom contractors, distributors and OEM partners.

Explore company capabilities

Quality inspection for Oulu microduct connector supply
Warehouse packing for Oulu microduct connector orders

B2B SOURCING SUPPORT

B2B purchasing support

The supplier’s Service page describes support from product consultation and customized solutions through production, delivery and after-sales. Include these details in a product enquiry:

  • Match seven 12/10 mm pathways to the fiber route.
  • Target quantity, model or size mix, sample needs and packing preference.
  • Drawings, route conditions, pressure or sealing tests and compliance documents.
  • Current MOQ, price, freight, sample timing and production timing to be confirmed in the quotation.

Company-level support and commercial terms should be reconfirmed for the selected product and order.

Share dimensions, route conditions and quantities for a product-specific quotation.Send product requirements

PROJECT SUPPORT

Plan the right microduct solution

Review the microduct route solutions and Service pages for project context, then confirm exact fit, documents and commercial terms in the quotation.

Discuss your project

FAQ

Frequently asked questions

What is a 7-way 12/10 mm bundle used for?

It provides seven larger HDPE pathways for direct-buried FTTH and air-blown cable routes.

What are the inner dimensions?

The source states 12 mm outside diameter and 10 mm inside diameter.

What is the bundle outside diameter?

The published bundle OD is 42.8 mm ±1.1 mm.

What tensile strength is stated?

The source states bundle tensile strength of at least 6,800 N and inner tensile of at least 620 N.

What temperatures are listed?

Storage and operation are stated as -40 to +70°C, with installation from -30 to +50°C.

What should a DB bundle enquiry include?

Provide way count, OD/ID, burial route, bend limits, drum packing, quantity and test documents.