Conectores para microductos

Acoplador reductor para microtubos

Zhejiang Oulu Automatic Equipment Co., Ltd. Descripción corta: DESCRIPCIÓN: Los conectores reductores permiten la interconexión entre dos microductos con diferentes diámetros exteriores. Típicamente este es el caso del punto de transición desde el microducto DB al DI que entra a la casa. Si no ha encontrado su tamaño correcto entre LIBRE DE METAL o REFORZADO, elija uno de estos. CARACTERÍSTICAS PRINCIPALES: ① Clips de seguridad incluidos ② Tecnología de inserción a presión ③ Presión de trabajo: máx. 25 bares                

CategoríaConectores para microductos

MICRODUCT CONNECTORS

Microduct reducer coupler for different-size duct connections

This microduct reducer coupler is presented for connecting two microducts with different outside diameters, such as a direct-buried-to-indoor transition.

The source lists FPG reducer codes, push-fit technology, pre-installed safety clips, IP68 protection and a maximum working-pressure statement. Confirm both tube dimensions, the correct tapered-hole code and the route test conditions before ordering.

TECHNICAL DETAILS

Published product facts

 Imagen de detalle del acoplador reductor de microducto 1  Imagen de detalle del acoplador reductor de microducto 2 Componentes
1 Casquillo POM
2 Pinza de bloqueo POM
3 Cartucho POM
4 Garra de bloqueo SUS301/304
5 Anillo de soporte POM
6 Anillo de sello TEP
7 Cuerpo PC2807
Tubo de resistencia
Material de la tubería HDPE、PE、Nylon、Polyurethane
Diámetro exterior de la tubería Φ3,Φ4,Φ5,Φ6,Φ7,Φ8,Φ10,Φ12,Φ16,Φ18,Φ20
Technical Parameter
Trabajando con fluidos Aire
Tensión 0,15~0,8 MPa Sin fugas
Prueba de tracción 400N
Presión de prueba 2,5 MPa
Rango de presión de operación 0~1,6 MPa
Temperatura ambiente y temperatura del fluido -40~60℃
Temperatura de instalación   -10℃/+50℃
Temperatura de soplado recomendada   -15℃/+35℃
Grado de protección IP68
Grado resistente a los rayos UV  F1
Fuerza de inserción 50N máx(5kg)
Esperanza de vida: 25 años
Estándares: EN 50411-2-8
ÍNDICE DE ARTÍCULOS
Código ANMASPC Pipe OD/ID Pipe OD/ID Tapered hole
FPG5-3/2.1 5/3.5 3/2.1 3.5>2.1
FPG5-4/2.8 5/3.5 4/2.8 3.5>2.8
FPG7-3/2.1 7/5.5 3/2.1 5.5>2.1
FPG7-4/2.8 7/5.5 4/2.8 5.5>2.8
FPG7-5/3.5 7/5.5 5/3.5 5,5>3,5
FPG8-3/2.1 8/6 3/2.1 6>2.1
FPG8-5/3.5 8/6 5/3.5 6>3.5
FPG8-7/5.5 8/6 7/5.5 6 > 5.5
FPG10-5/3.5 10/8 5/3.5 8>3.5
FPG10-7/5.5 10/8 7/5.5 8>5.5
FPG10-8/6 10/8 8/6 8>6
FPG12-7/5.5 12/10 10/8 10>5.5
FPG12-8/6 12/10 7/5.5 10>6
FPG12-10/8 12/10 12/10 10>8
FPG14-10/8 14/12 8/6 12>8
FPG14-12/10 14/12 10/8 12>10
FPG16-10/8 16/13 10/8 13>8
FPG16-12/10 16/13 12/10 13>10
FPG20-16/14 20/16 16/13 16>13
Dimensiones totales
Imagen de detalle 3 de acoplador reductor de microducto                 
Modelo A B C D H EA ED EC
FPG5-3 3.2 2.1 8.4 7.8 32.2 5.2 10.7 11.8
FPG7-3 3.2 3.5 8.4 7.8 33.8 7.2 13.4 14.7
FPG8-3 3.2 3.5 8.4 7.8 33.8 8.3 13.4 14.7
FPG7-5 5.2 3.5 11.9 10.7 37.5 7.2 13.4 14.8
FPG8-5 5.2 3.5 11.9 10.7 37.5 8.3 13.4 14.8
FPG10-7 7.3 5.5 14.7 13.4 41 10.3 15.6 16.7
FPG10-8 8.3 5.5 14.7 13.4 41 10.3 15.6 16.7
FPG12-8 8.3 6 15.4 13.4 43 12.4 17.4 19.1
FPG12-10 10.3 8 16.7 15.6 45 12.4 17.4 19.1
FPG14-12 14.5 10 21.2 20 48.4 12.4 17.4 19.1
FPG16-12 16.5 10 24.4 23 51 12.4 17.5 19.3

SELECTION GUIDE

Choosing a reducer coupler for a duct transition

Use these checkpoints to prepare a product-specific enquiry and close the fit, test and documentation questions before ordering.

  1. Measure both sidesSend the OD/ID and material of the larger and smaller microduct.
  2. Identify the transitionState whether the joint is DB-to-DI, house entry, chamber or another route point.
  3. Match the FPG codeRequest the correct reducer code and tapered-hole dimensions from the published table.
  4. Confirm the testsShare pressure, leak, pull and cable-blowing requirements plus current document needs.

OEM & PROJECT CAPABILITY

Company capability for telecom supply

Oulu Automatic Equipment presents itself as a supplier of microduct connectors, HDPE microduct systems, cable blowing accessories and pneumatic fittings for telecom contractors, distributors and OEM partners.

Explore company capabilities

Quality inspection for Oulu microduct connector supply
Warehouse packing for Oulu microduct connector orders

B2B SOURCING SUPPORT

B2B purchasing support

The supplier’s Service page describes support from product consultation and customized solutions through production, delivery and after-sales. Include these details in a product enquiry:

  • Send the OD/ID and material of the larger and smaller microduct.
  • Target quantity, model or size mix, sample needs and packing preference.
  • Drawings, route conditions, pressure or sealing tests and compliance documents.
  • Current MOQ, price, freight, sample timing and production timing to be confirmed in the quotation.

Company-level support and commercial terms should be reconfirmed for the selected product and order.

Share dimensions, route conditions and quantities for a product-specific quotation.Send product requirements

PROJECT SUPPORT

Plan the right microduct solution

Review the microduct route solutions y Servicio pages for project context, then confirm exact fit, documents and commercial terms in the quotation.

Discuss your project

Preguntas frecuentes

Preguntas frecuentes

What is a microduct reducer coupler used for?

It connects two compatible microducts with different outside diameters, often at a route transition.

Can it connect DB and DI microducts?

The source describes DB-to-DI transition use, such as entering a house. Confirm both tube specifications for the selected FPG code.

How do I select an FPG reducer size?

Provide OD/ID and material for both ducts and request the matching FPG code and tapered-hole dimensions.

What pressure data is published?

The source states 0–1.6 MPa operating pressure and 2.5 MPa proof pressure. Confirm the test method and project safety margin.

Does the reducer have outdoor protection?

IP68 is stated on the source page. Confirm environmental exposure and current model evidence before specification.

What should a reducer-coupler quotation include?

Send both duct dimensions, transition location, route conditions, tests, quantity, packing and drawing or compliance requirements.