Zhejiang Oulu Automatic Equipment Co., Ltd. Short Description: DESCRIPTION: Reducing connectors allows interconnection between two micro-ducts with different outer diameter. Typically this is the case of transition point from DB to DI micro-duct entering the house. If you have not fnd your correct size among METAL FREE or REINFORCED than choose one of these. MAIN FEATURES: ① Safety clips included ② Push-ft technology ③ Working Pressure: max. 25 bars
Microduct reducer coupler for different-size duct connections
This microduct reducer coupler is presented for connecting two microducts with different outside diameters, such as a direct-buried-to-indoor transition.
The source lists FPG reducer codes, push-fit technology, pre-installed safety clips, IP68 protection and a maximum working-pressure statement. Confirm both tube dimensions, the correct tapered-hole code and the route test conditions before ordering.
TECHNICAL DETAILS
Published product facts
Components
1
Collet
POM
2
Locking Clip
POM
3
Cartridge
POM
4
Lock Claw
SUS301/304
5
Support Ring
POM
6
Seal Ring
TEP
7
Body
PC2807
Fit Tube
Pipe material
HDPE、PE、Nylon、Polyurethane
Outer diameter of pipe
Φ3,Φ4,Φ5,Φ6,Φ7,Φ8,Φ10,Φ12,Φ16,Φ18,Φ20
Technical Parameter
Working with fluids
Air
Tightness
0.15~0.8MPa No Leak
Pull test
400N
Proof pressure
2.5MPa
Operating pressure range
0~1.6MPa
Ambient temperature and fluid temperature
-40~60℃
Installation Temperature
-10℃/+50℃
Recommended Blowing Temperature
-15℃/+35℃
Degree of protection
IP68
UV-resistant grade
F1
Insertion force
50N max(5kg)
Lifespan:
25 years
StAndards:
EN 50411-2-8
TABLE OF ARTICLES
ANMASPC Code
Pipe OD/ID
Pipe OD/ID
Tapered hole
FPG5-3/2.1
5/3.5
3/2.1
3.5>2.1
FPG5-4/2.8
5/3.5
4/2.8
3.5>2.8
FPG7-3/2.1
7/5.5
3/2.1
5.5>2.1
FPG7-4/2.8
7/5.5
4/2.8
5.5>2.8
FPG7-5/3.5
7/5.5
5/3.5
5.5>3.5
FPG8-3/2.1
8/6
3/2.1
6>2.1
FPG8-5/3.5
8/6
5/3.5
6>3.5
FPG8-7/5.5
8/6
7/5.5
6>5.5
FPG10-5/3.5
10/8
5/3.5
8>3.5
FPG10-7/5.5
10/8
7/5.5
8>5.5
FPG10-8/6
10/8
8/6
8>6
FPG12-7/5.5
12/10
10/8
10>5.5
FPG12-8/6
12/10
7/5.5
10>6
FPG12-10/8
12/10
12/10
10>8
FPG14-10/8
14/12
8/6
12>8
FPG14-12/10
14/12
10/8
12>10
FPG16-10/8
16/13
10/8
13>8
FPG16-12/10
16/13
12/10
13>10
FPG20-16/14
20/16
16/13
16>13
Overall Dimensions
Model
A
B
C
D
H
EA
ED
EC
FPG5-3
3.2
2.1
8.4
7.8
32.2
5.2
10.7
11.8
FPG7-3
3.2
3.5
8.4
7.8
33.8
7.2
13.4
14.7
FPG8-3
3.2
3.5
8.4
7.8
33.8
8.3
13.4
14.7
FPG7-5
5.2
3.5
11.9
10.7
37.5
7.2
13.4
14.8
FPG8-5
5.2
3.5
11.9
10.7
37.5
8.3
13.4
14.8
FPG10-7
7.3
5.5
14.7
13.4
41
10.3
15.6
16.7
FPG10-8
8.3
5.5
14.7
13.4
41
10.3
15.6
16.7
FPG12-8
8.3
6
15.4
13.4
43
12.4
17.4
19.1
FPG12-10
10.3
8
16.7
15.6
45
12.4
17.4
19.1
FPG14-12
14.5
10
21.2
20
48.4
12.4
17.4
19.1
FPG16-12
16.5
10
24.4
23
51
12.4
17.5
19.3
PRODUCT DETAIL IMAGES
Product Detail
The original product detail images are retained below for visual reference. Confirm the quoted model and dimensions before ordering.
SELECTION GUIDE
Choosing a reducer coupler for a duct transition
Use these checkpoints to prepare a product-specific enquiry and close the fit, test and documentation questions before ordering.
Measure both sidesSend the OD/ID and material of the larger and smaller microduct.
Identify the transitionState whether the joint is DB-to-DI, house entry, chamber or another route point.
Match the FPG codeRequest the correct reducer code and tapered-hole dimensions from the published table.
Confirm the testsShare pressure, leak, pull and cable-blowing requirements plus current document needs.
OEM & PROJECT CAPABILITY
Company capability for telecom supply
Oulu Automatic Equipment presents itself as a supplier of microduct connectors, HDPE microduct systems, cable blowing accessories and pneumatic fittings for telecom contractors, distributors and OEM partners.
The supplier’s Service page describes support from product consultation and customized solutions through production, delivery and after-sales. Include these details in a product enquiry:
Send the OD/ID and material of the larger and smaller microduct.
Target quantity, model or size mix, sample needs and packing preference.
Drawings, route conditions, pressure or sealing tests and compliance documents.
Current MOQ, price, freight, sample timing and production timing to be confirmed in the quotation.
Company-level support and commercial terms should be reconfirmed for the selected product and order.
Share dimensions, route conditions and quantities for a product-specific quotation.Send product requirements
PROJECT SUPPORT
Plan the right microduct solution
Review the microduct route solutions and Service pages for project context, then confirm exact fit, documents and commercial terms in the quotation.
Microduct Type I splice boxes are essential components in fiber optic networks, particularly in blown fiber installations. Their primary function is to provide protection and organization for fiber splices, ensuring the integrity and reliability of the network.
Zhejiang Oulu Automatic Equipment Co., Ltd. presents its high-quality Microduct Type T splice boxes, essential for optimal performance in fiber optic networks, especially in blown fiber installations. Designed to ensure the protection and organization of fiber splices, these splice boxes...
Blank plugs effectively seal empty HDPE duct ends. These plugs are removable & reusable.Proper sealing of your conduits and subducts is important to prevent the costly flooding of buildings and sedimentation inside.