{"id":4779,"date":"2026-10-20T00:00:00","date_gmt":"2026-10-20T00:00:00","guid":{"rendered":"https:\/\/microductconnector.com\/?p=4779"},"modified":"2026-10-23T09:44:04","modified_gmt":"2026-10-23T09:44:04","slug":"install-stainless-steel-pneumatic-fittings","status":"publish","type":"post","link":"https:\/\/microductconnector.com\/tr\/blog\/install-stainless-steel-pneumatic-fittings\/","title":{"rendered":"Paslanmaz \u00c7elik Pn\u00f6matik Ba\u011flant\u0131 Par\u00e7alar\u0131n\u0131 Tala\u015flanma veya S\u0131z\u0131nt\u0131 Olmadan Nas\u0131l Kurars\u0131n\u0131z?"},"content":{"rendered":"<article>\n<p>Kurulum s\u0131ras\u0131nda d\u00f6nd\u00fcrmesi zorla\u015fan paslanmaz bir ba\u011flant\u0131 eleman\u0131, yanl\u0131\u015f di\u015flenme yapm\u0131\u015f, kirlenmi\u015f veya a\u015f\u0131nmaya ba\u015flam\u0131\u015f olabilir. Daha uzun bir anahtar kullanmak, d\u00fczeltilebilir bir montaj sorununu hasar g\u00f6rm\u00fc\u015f di\u015flere ve bak\u0131m yap\u0131lamayan bir ba\u011flant\u0131y\u0131 d\u00f6n\u00fc\u015ft\u00fcrebilir. Bir ba\u015fka s\u0131z\u0131nt\u0131 da di\u015fli ba\u011flant\u0131 yerine boru soketinden kaynaklan\u0131yor olabilir; bu nedenle fazla s\u0131kma i\u015flemi, as\u0131l ar\u0131zay\u0131 tamamen g\u00f6zden ka\u00e7\u0131rabilir. G\u00fcvenilir bir montaj i\u00e7in, di\u015f uyumlulu\u011fu, kullan\u0131lacak s\u0131zd\u0131rmazl\u0131k y\u00f6ntemi, aletin konumu ve boru haz\u0131rl\u0131\u011f\u0131 ayr\u0131 ayr\u0131 kontrol edilmelidir. Bu k\u0131lavuz, s\u00f6z konusu kontrolleri a\u00e7\u0131klar, montaj\u0131 ne zaman durdurman\u0131z gerekti\u011fini belirtir ve evrensel bir tork de\u011feri uygulamadan veya paslanmaz \u00e7eli\u011fi korozyona kar\u015f\u0131 ba\u011f\u0131\u015f\u0131k gibi g\u00f6rmeden ba\u011flant\u0131y\u0131 nas\u0131l do\u011frulayaca\u011f\u0131n\u0131z\u0131 anlat\u0131r.<\/p>\n<p>Y\u00fckle <strong>paslanmaz \u00e7elik pn\u00f6matik ba\u011flant\u0131 par\u00e7alar\u0131<\/strong> Tam olarak t\u00fcp ba\u011flant\u0131s\u0131n\u0131, di\u015f uyumunu ve \u00e7al\u0131\u015fma ko\u015fullar\u0131n\u0131 onaylad\u0131ktan sonra. Di\u015flerin temiz ve hasars\u0131z oldu\u011fundan emin olun; onaylanm\u0131\u015f uyum \u00e7iftini elle takmaya ba\u015flay\u0131n; belirtilen s\u0131zd\u0131rmazl\u0131k malzemesini veya y\u00fczey s\u0131zd\u0131rmazl\u0131\u011f\u0131n\u0131 kullan\u0131n; ve belirlenmi\u015f anahtar y\u00fczeylerinden, se\u00e7ilen \u00fcreticinin talimatlar\u0131na g\u00f6re s\u0131k\u0131n. Anormal diren\u00e7 olu\u015fursa durun. Y\u0131pranmay\u0131 \u00f6nlemek i\u00e7in yaln\u0131zca daha fazla kuvvet uygulamak yeterli de\u011fildir; s\u00fcrt\u00fcnme ve temas ko\u015fullar\u0131 da kontrol edilmelidir. Onaylanm\u0131\u015f boruyu ayr\u0131 olarak haz\u0131rlay\u0131n ve tamamen yerine yerle\u015ftirin, yan y\u00fcklenmeye kar\u015f\u0131 destekleyin; ard\u0131ndan bas\u0131n\u00e7 g\u00fcvenli bir \u015fekilde yeniden sa\u011fland\u0131ktan sonra kontroll\u00fc bir s\u0131z\u0131nt\u0131 ve i\u015flev testi ger\u00e7ekle\u015ftirin.<\/p>\n<h2>Paslanmaz \u00e7elik di\u015fler neden montaj s\u0131ras\u0131nda kavrama yapabilir?<\/h2>\n<p><strong>Di\u015f t\u0131kanmas\u0131<\/strong> y\u00fck alt\u0131nda metal y\u00fczeylerin birbirine s\u00fcrt\u00fcnmesi sonucu olu\u015fabilen yap\u0131\u015fma hasar\u0131d\u0131r. ASSDA\u2019n\u0131n <a href=\"https:\/\/www.assda.asn.au\/publications\/technical-faqs\/galling-and-its-control\" rel=\"noopener nofollow\" target=\"_blank\">Teknik SSS 5<\/a> S\u00fcrt\u00fcnmenin koruyucu oksit tabakas\u0131n\u0131 bozarak yerel metal temas\u0131na ve so\u011fuk kaynaklanmas\u0131na yol a\u00e7abilece\u011fini a\u00e7\u0131klar. Kir, t\u0131rt\u0131klar, k\u00f6t\u00fc uyum ve a\u015f\u0131r\u0131 temas gerilmesi montaj\u0131 karma\u015f\u0131kla\u015ft\u0131r\u0131r. \u00c7ekme, yanl\u0131\u015f s\u0131zd\u0131rmazl\u0131k d\u00fczeninin se\u00e7ilmesinden kaynaklanan bir s\u0131zd\u0131rmazl\u0131k sorunundan farkl\u0131d\u0131r.<\/p>\n<p>ASSDA\u2019n\u0131n belgesi genel olarak paslanmaz ba\u011flant\u0131 elemanlar\u0131n\u0131 ele almaktad\u0131r. Burada yer alan c\u0131vata tork tablolar\u0131, pn\u00f6matik montaj i\u00e7in ge\u00e7erli de\u011ferleri ifade etmemektedir. Temiz temas y\u00fczeyleri, uygun ya\u011flama ve kontroll\u00fc kuvvetle ilgili temel prensipleri dikkate al\u0131n; ancak ger\u00e7ek montaj, ba\u011flant\u0131 yuvas\u0131 ve y\u00fczey ko\u015fullar\u0131na g\u00f6re tork veya d\u00f6n\u00fc\u015f say\u0131s\u0131 y\u00f6n\u00fcndeki talimatlar\u0131 edinin. Bir s\u0131zd\u0131rmazl\u0131k maddesi s\u00fcrt\u00fcnmeyi de\u011fi\u015ftirebilece\u011finden, kuru bir montaj i\u00e7in tasarlanm\u0131\u015f bir talimat otomatik olarak ya\u011flanm\u0131\u015f bir montaja uygulanamaz.<\/p>\n<p>Bir 304 par\u00e7as\u0131 ve bir 316 par\u00e7as\u0131 kullanmak kesin bir \u00e7\u00f6z\u00fcm de\u011fildir. ASSDA, bunlar\u0131n sertlik fark\u0131n\u0131n a\u015f\u0131nmay\u0131 \u00f6nlemek i\u00e7in yetersiz olabilece\u011fini \u00f6zellikle belirtmektedir. Bas\u0131n\u00e7l\u0131 b\u00f6lgenin tasar\u0131m\u0131n\u0131, kullan\u0131lan ortam\u0131 ve temizlik gerekliliklerini kontrol etmeden malzeme de\u011fi\u015ftirme veya at\u00f6lye tipi kaynamaz bile\u015fik eklemeyin.<\/p>\n<h2>\u0130lk di\u015flenme ger\u00e7ekle\u015fmeden \u00f6nce neler kontrol edilmelidir?<\/h2>\n<p>Tam erkek ve di\u015fi di\u015f tan\u0131mlamalar\u0131n\u0131, standart, boyut, vida ad\u0131m\u0131 ve konikli\u011fi dahil olmak \u00fczere belirleyin. Port spesifikasyonunu boru d\u0131\u015f \u00e7ap\u0131ndan ay\u0131r\u0131n. S\u0131zd\u0131rmazl\u0131\u011f\u0131n konik di\u015flerde, bir rondelada, bir O-halkada, bir conta veya belirlenmi\u015f bir oturma y\u00fczeyinde ger\u00e7ekle\u015fip ger\u00e7ekle\u015fmedi\u011fini kontrol edin. \u201cPaslanmaz 1\/4 in\u00e7\u201d bir ba\u011flant\u0131 sat\u0131n almak veya monte etmek i\u00e7in yeterli bilgi sa\u011flamaz.<\/p>\n<figure class=\"wp-block-image size-full\" style=\"width:50%;max-width:600px;margin:1.5rem auto\"><img alt=\"External inspection of the threaded interface before stainless fitting installation\" class=\"wp-image-5084\" decoding=\"async\" height=\"800\" loading=\"lazy\" src=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/blue-v3-1020-inline1-thread-surface-preassembly-inspection-branded.webp\" style=\"width:100%;height:auto;display:block\" width=\"600\" srcset=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/blue-v3-1020-inline1-thread-surface-preassembly-inspection-branded.webp 600w, https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/blue-v3-1020-inline1-thread-surface-preassembly-inspection-branded-225x300.webp 225w, https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/blue-v3-1020-inline1-thread-surface-preassembly-inspection-branded-9x12.webp 9w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><figcaption>Montaj y\u00fck\u00fc uygulamadan \u00f6nce g\u00f6r\u00fcn\u00fcr ba\u011flant\u0131 y\u00fczeylerini inceleyin.<\/figcaption><\/figure>\n<p>Hasarl\u0131 ba\u015flang\u0131\u00e7lar, t\u0131rt\u0131klar, kirlenme ve daha \u00f6nceki s\u0131k\u0131\u015fma belirtileri a\u00e7\u0131s\u0131ndan inceleyin. Haz\u0131rl\u0131k s\u0131ras\u0131nda a\u00e7\u0131k boru ve ba\u011flant\u0131 u\u00e7lar\u0131n\u0131 kirlerden koruyun. \u00dcreticinin tasar\u0131m\u0131n\u0131n izin verdi\u011fi durumlarda, do\u011fru \u015fekilde hizalanm\u0131\u015f \u00e7ifti elle takmaya ba\u015flay\u0131n. Beklenmedik bir \u015fekilde s\u0131k\u0131\u015fmas\u0131 halinde durun, g\u00fcvenli bir prosed\u00fcrle s\u00f6k\u00fcn ve nedenini tespit edin. S\u0131kma kuvvetini vida \u00f6l\u00e7\u00fcs\u00fc olarak kullanmay\u0131n. \u015eantiyenin <a href=\"https:\/\/microductconnector.com\/blog\/bsp-or-npt-push-in-fittings-thread-matching-guide\/\">\u0130plik uyumland\u0131rma k\u0131lavuzu<\/a> Aray\u00fcz tan\u0131mlamas\u0131n\u0131 s\u0131zd\u0131rmazl\u0131k se\u00e7imiyle ay\u0131rman\u0131za yard\u0131mc\u0131 olur.<\/p>\n<table>\n<thead>\n<tr>\n<th>\u00d6ny\u00fckleme \u00f6ncesi \u00f6\u011fe<\/th>\n<th>Gerekli kan\u0131t<\/th>\n<th>Durma nedeni<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>\u0130\u015flemci \u00e7ekirde\u011fi \u00e7ifti<\/td>\n<td>Matching standard and approved mating designations<\/td>\n<td>Uncertain profile, crossed start or damaged thread<\/td>\n<\/tr>\n<tr>\n<td>Seal arrangement<\/td>\n<td>Drawing and approved sealing instruction<\/td>\n<td>Missing seat, incompatible sealant or damaged face<\/td>\n<\/tr>\n<tr>\n<td>Tool access<\/td>\n<td>Identified wrench flats and clearance<\/td>\n<td>Tool would load a release ring or swivel body<\/td>\n<\/tr>\n<tr>\n<td>T\u00fcp aray\u00fcz\u00fc<\/td>\n<td>Approved OD, tolerance, material and insertion depth<\/td>\n<td>Scored, oval or unsuitable tubing<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Which sealant and tightening method should be used?<\/h2>\n<p>Follow the exact connector and port instructions. A pre-sealed fitting may have limits on adjustment and reuse. A face-sealed parallel thread may need a specified gasket rather than tape on the thread. A tapered joint may use an approved coating or compound applied so fragments cannot enter the pneumatic passage. Excess material can contaminate downstream valves and instruments.<\/p>\n<p><strong>Controlled tightening<\/strong> means using the instruction for the named combination of thread, material and surface condition. For example, the SMC KQG2 catalogue gives different tightening ranges for different NPT\/R sizes in that series. That demonstrates why one workshop number is inadequate. Those values must not be used as Oulu specifications or applied to an unrelated thread. If the supplier has not provided an installation limit, obtain it before standardizing assembly.<\/p>\n<p>Apply the tool to the intended hexagon and support the mating component as instructed. Do not grip the release button, distort the cylindrical body or transmit torque through an unsupported tube. SMC&#8217;s KQG2 precautions also distinguish a joint that may be positioned after connection from a rotary joint designed for continuous movement. Similar-looking elbows are not automatically swivels for dynamic service.<\/p>\n<h2>How should the tube be inserted without creating another leak?<\/h2>\n<p>Identify the tube OD and approved material, then cut a clean square end. Remove debris without scratching the sealing surface. Follow the connector&#8217;s insertion depth and retention-check method. A tube that passes the gripping feature but does not reach the required seat may feel secure while still leaking. A softened or enlarged used tube may no longer match the original interface.<\/p>\n<figure class=\"wp-block-image size-full\" style=\"width:50%;max-width:600px;margin:1.5rem auto\"><img alt=\"Inspection of a tube end and fitting entry as separate possible leak locations\" class=\"wp-image-5085\" decoding=\"async\" height=\"800\" loading=\"lazy\" src=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/blue-v3-1020-inline2-tube-and-thread-leak-locations-branded-v2.webp\" style=\"width:100%;height:auto;display:block\" width=\"600\" srcset=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/blue-v3-1020-inline2-tube-and-thread-leak-locations-branded-v2.webp 600w, https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/blue-v3-1020-inline2-tube-and-thread-leak-locations-branded-v2-225x300.webp 225w, https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/blue-v3-1020-inline2-tube-and-thread-leak-locations-branded-v2-9x12.webp 9w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><figcaption>Thread-side and tube-side sealing require separate checks.<\/figcaption><\/figure>\n<p>SMC&#8217;s KQG2 specific precautions warn that soft polyurethane can fold during insertion in its grease-free construction. They also advise replacing tubing whose OD has enlarged after high-temperature or extended use. These observations support inspection of the tube, but they do not justify lubricating a fitting against its instructions. The <a href=\"https:\/\/microductconnector.com\/blog\/pneumatic-pipe-connector-installation-guide\/\">pn\u00f6matik ba\u011flant\u0131 eleman\u0131 kurulum k\u0131lavuzu<\/a> gives related preparation and routing checks.<\/p>\n<p>Provide a suitable straight approach and independent tube support. Do not use the connector as a structural anchor for hose weight or actuator motion. Check tool and tube-release clearance before closing the cabinet or panel. If a connection cannot be accessed for inspection, redesign the layout rather than relying on a difficult blind assembly.<\/p>\n<h2>Does choosing 316 make a fitting suitable for washdown or chemicals?<\/h2>\n<p>No body grade establishes the suitability of the complete assembly. Identify the external cleaner as well as the internal medium, concentration, temperature, dwell time and rinse conditions. Check seals, tube, retaining parts and thread treatment against the <strong>operating envelope<\/strong>. ASSDA&#8217;s <a href=\"https:\/\/www.assda.asn.au\/publications\/technical-faqs\/faq-8-general-corrosion-resistance\" rel=\"noopener nofollow\" target=\"_blank\">general corrosion guidance<\/a> explains why contaminants, crevices and chemical conditions change stainless performance.<\/p>\n<p>Grade 316 may merit consideration where chloride exposure challenges 304, but it is not immune to pitting or every cleaning chemical. A visual surface finish cannot establish hygienic certification or food-contact approval. Specify the exact material and required documentation for the selected model. Do not claim a stainless pneumatic fitting is suitable for direct food contact merely because it will be installed near a washdown line.<\/p>\n<table>\n<thead>\n<tr>\n<th>Assembly condition<\/th>\n<th>Nelerin do\u011frulanmas\u0131 gerekiyor<\/th>\n<th>Unsupported shortcut<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Dry compressed air<\/td>\n<td>Complete pressure-temperature range and tube approval<\/td>\n<td>Body strength sets every component&#8217;s limit<\/td>\n<\/tr>\n<tr>\n<td>Water or cleaning exposure<\/td>\n<td>G\u00f6vde, conta ve boru uyumlulu\u011fu<\/td>\n<td>316 means universally corrosion-proof<\/td>\n<\/tr>\n<tr>\n<td>Clean process area<\/td>\n<td>Cleanliness and contact-zone restrictions<\/td>\n<td>Metal appearance proves food suitability<\/td>\n<\/tr>\n<tr>\n<td>Repeated service removal<\/td>\n<td>Reuse limits, seal replacement and thread condition<\/td>\n<td>More sealant restores every used joint<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>What should the installation test and handover include?<\/h2>\n<p>Use the machine&#8217;s energy-control procedure before assembly or any remedial work. After the connection is complete and access is safe, restore pressure in a controlled way within the approved operating range. Use an application-compatible leak-detection method and inspect the relevant joints. Do not overtighten a pressurized joint in an attempt to stop bubbles.<\/p>\n<p>Check representative temperature and motion conditions, not just a brief stationary test. A pressure-decay result may include other connected volumes and temperature effects; interpret it under an agreed procedure. If there is low flow without a local leak, investigate tubing ID, fitting passage and other restrictions. Repeating the leak test does not diagnose a flow bottleneck.<\/p>\n<p>Record the component code, installation instruction revision, seal arrangement and accepted test condition. Oulu&#8217;s <a href=\"https:\/\/microductconnector.com\/product\/zhejiang-factory-stainless-steel-pcf-female-thread-straight-push-fit-pipe-fitting-product\/\">female-thread straight push-fit fitting<\/a> illustrates why both ends need specification: the tube socket and mating male thread must be identified separately. Request the current drawing and operating limits for the quoted variant. Include the approved combination in the site&#8217;s <a href=\"https:\/\/microductconnector.com\/blog\/pneumatic-fittings-maintenance-guide\/\">pneumatic maintenance schedule<\/a> so later repairs preserve the installation method.<\/p>\n<h2>S\u0131k\u00e7a sorulan sorular<\/h2>\n<h3>Why choose stainless steel pneumatic fittings instead of plated fittings?<\/h3>\n<p>Consider stainless when the documented exposure and maintenance requirements justify it. Compare the entire assembly, including seals and tubing, rather than assuming body material alone determines durability. Plating condition and cleaner compatibility also need evaluation.<\/p>\n<h3>How do you match tube OD and thread type to stainless steel pneumatic fittings?<\/h3>\n<p>Identify tube OD, units, material and tolerance separately from the equipment thread. Confirm the complete thread designation and seal location from the drawings. Similar outside dimensions do not establish an approved mating pair.<\/p>\n<h3>Which stainless grade is suitable for corrosive or washdown areas?<\/h3>\n<p>Select from the actual chemical, concentration, temperature and exposure pattern. Grade 316 is worth evaluating for some chloride conditions, but neither 304 nor 316 is universally suitable. Obtain confirmation for the complete fitting and its cleaning conditions.<\/p>\n<h3>How do you prevent galling when installing stainless steel pneumatic fittings?<\/h3>\n<p>Use clean undamaged matching threads, correct alignment, an approved sealing or lubrication method and controlled tightening at the designated flats. Stop if resistance is abnormal. Do not apply generic bolt torque values or unapproved anti-seize.<\/p>\n<h3>What pressure and temperature rating should the fitting have?<\/h3>\n<p>Its permitted range must cover the actual medium, local temperature and maximum pressure including transients, together with the tube and port. Use the exact model&#8217;s current data. Proof and burst pressures are not continuous operating limits.<\/p>\n<h3>Can stainless steel pneumatic fittings be used with compressed air, water and chemicals?<\/h3>\n<p>Only when the manufacturer approves the exact model and materials for those conditions. Evaluate body, seals, tubing and thread treatment together. A stainless body and a chemical-resistance chart do not establish complete product performance.<\/p>\n<h2>Kaynak\u00e7a<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.assda.asn.au\/publications\/technical-faqs\/galling-and-its-control\" rel=\"noopener nofollow\" target=\"_blank\">ASSDA: Technical FAQ 5, Galling and its Control<\/a> \u2014 mechanism and friction\/assembly controls; fastener torque tables are not fitting ratings.<\/li>\n<li><a href=\"https:\/\/content2.smcetech.com\/pdf\/KQG2.pdf\" rel=\"noopener nofollow\" target=\"_blank\">SMC: KQG2 catalogue and specific product precautions<\/a> \u2014 series-specific tightening, tube insertion, mechanical-load and fluid limitations.<\/li>\n<li><a href=\"https:\/\/www.assda.asn.au\/publications\/technical-faqs\/faq-8-general-corrosion-resistance\" rel=\"noopener nofollow\" target=\"_blank\">ASSDA: Technical FAQ 8, General Corrosion Resistance<\/a> \u2014 chemical and environmental limits.<\/li>\n<\/ul>\n<h2>\u00d6zet<\/h2>\n<p>Installing a stainless pneumatic fitting correctly means controlling two different interfaces. Match and inspect the threaded port, use its approved sealing method and tightening instruction, and stop when resistance suggests damage or galling. Prepare the approved tubing separately and remove side load before testing. Stainless steel can address a material requirement, but it cannot correct an incompatible seal, unsuitable tube or wrong port. Keep the selected model, assembly instruction and test conditions with the maintenance record so future replacements follow the same method. Oulu can review a fitting enquiry against the supplied tube and port details; the decision should remain tied to the exact component and operating conditions rather than a generic stainless description.<\/p>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>Uyumlu di\u015flere sahip, onayl\u0131 s\u0131zd\u0131rmazl\u0131\u011fa ve kontroll\u00fc s\u0131k\u0131lmaya sahip paslanmaz \u00e7elik pn\u00f6matik ba\u011flant\u0131 elemanlar\u0131n\u0131 tak\u0131n. A\u015f\u0131nmay\u0131, boru hasar\u0131n\u0131 ve tekrarlayan s\u0131z\u0131nt\u0131lar\u0131 \u00f6nleyin.<\/p>","protected":false},"author":2,"featured_media":5331,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[21],"tags":[],"class_list":["post-4779","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-insights"],"_links":{"self":[{"href":"https:\/\/microductconnector.com\/tr\/wp-json\/wp\/v2\/posts\/4779","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/microductconnector.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/microductconnector.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/tr\/wp-json\/wp\/v2\/comments?post=4779"}],"version-history":[{"count":2,"href":"https:\/\/microductconnector.com\/tr\/wp-json\/wp\/v2\/posts\/4779\/revisions"}],"predecessor-version":[{"id":5103,"href":"https:\/\/microductconnector.com\/tr\/wp-json\/wp\/v2\/posts\/4779\/revisions\/5103"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/tr\/wp-json\/wp\/v2\/media\/5331"}],"wp:attachment":[{"href":"https:\/\/microductconnector.com\/tr\/wp-json\/wp\/v2\/media?parent=4779"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/microductconnector.com\/tr\/wp-json\/wp\/v2\/categories?post=4779"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/microductconnector.com\/tr\/wp-json\/wp\/v2\/tags?post=4779"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}