{"id":5414,"date":"2026-11-09T00:00:00","date_gmt":"2026-11-09T00:00:00","guid":{"rendered":"https:\/\/microductconnector.com\/?p=5414"},"modified":"2026-11-02T06:45:11","modified_gmt":"2026-11-02T06:45:11","slug":"plastic-duct-coupler-outdoor-selection","status":"publish","type":"post","link":"https:\/\/microductconnector.com\/fr\/blog\/plastic-duct-coupler-outdoor-selection\/","title":{"rendered":"Comment choisir un coupleur de conduit en plastique pour les trac\u00e9s de fibres optiques ext\u00e9rieurs ?"},"content":{"rendered":"<article>\n<p>A <strong>raccord de conduit en plastique<\/strong> Il convient de choisir le connecteur en fonction de l\u2019environnement d\u2019installation d\u00e9fini, et non pas uniquement sur la base d\u2019une mention \u00ab pour usage ext\u00e9rieur \u00bb. Un armoire abrit\u00e9e, une chambre d\u2019acc\u00e8s humide et un raccord enterr\u00e9 directement sont soumis \u00e0 des conditions d\u2019exposition diff\u00e9rentes. Le connecteur appropri\u00e9 doit pr\u00e9senter une compatibilit\u00e9 dimensionnelle, une \u00e9tanch\u00e9it\u00e9, une tenue m\u00e9canique et une protection document\u00e9es, adapt\u00e9es \u00e0 l\u2019emplacement d\u2019installation r\u00e9el.<\/p>\n<p>Commencez par \u00e9tudier le parcours des conduits et des c\u00e2bles, puis \u00e9valuez les conditions relatives \u00e0 l\u2019eau, \u00e0 la lumi\u00e8re solaire, \u00e0 la temp\u00e9rature et aux contraintes m\u00e9caniques. Demandez des justificatifs pr\u00e9cis concernant le produit en question et ses accessoires requis. La couleur noire, un corps d\u2019apparence \u00e9paisse ou une d\u00e9nomination de produit comportant l\u2019expression \u00ab pour pose souterraine \u00bb ne constituent pas, \u00e0 elles seules, une garantie d\u2019ad\u00e9quation.<\/p>\n<h2>Le raccord de conduit en plastique sera-t-il expos\u00e9, install\u00e9 dans une chambre ou enterr\u00e9 directement ?<\/h2>\n<p>Indiquez si le joint est expos\u00e9 aux rayons du soleil, prot\u00e9g\u00e9 \u00e0 l\u2019int\u00e9rieur d\u2019un enceinte, install\u00e9 dans une chambre ou plac\u00e9 directement dans le sol. Pr\u00e9cisez \u00e9galement l\u2019acc\u00e8s pr\u00e9vu pour la maintenance et la possibilit\u00e9 de pr\u00e9sence d\u2019eau stagnante. L\u2019exposition pendant le transport, le stockage et l\u2019installation peut diff\u00e9rer de l\u2019emplacement d\u2019exploitation final.<\/p>\n<p>Une enceinte peut prot\u00e9ger un connecteur des rayons directs du soleil tout en l\u2019exposant \u00e0 l\u2019eau et aux manipulations lors des travaux ult\u00e9rieurs sur le r\u00e9seau. Un armoire a\u00e9rienne peut r\u00e9duire l\u2019exposition directe \u00e0 la pluie, mais reste soumise aux variations de temp\u00e9rature et \u00e0 des chemins de c\u00e2bles encombr\u00e9s. L\u2019enterrage direct implique quant \u00e0 lui des contraintes m\u00e9caniques et d\u2019installation sp\u00e9cifiques. Ces conditions doivent \u00eatre d\u00e9crites s\u00e9par\u00e9ment dans la demande d\u2019achat.<\/p>\n<figure style=\"width:50%;max-width:600px;margin:24px auto;text-align:center;\"><img alt=\"Comparison of a chamber, exposed location and generic buried route\" decoding=\"async\" height=\"800\" loading=\"lazy\" src=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/11\/plastic-duct-coupler-outdoor-selection-detail.webp\" style=\"display:block;width:100%;height:auto;border-radius:6px;\" width=\"600\"\/><figcaption style=\"font-size:14px;line-height:1.5;color:#52616d;margin-top:8px;\">Comparaison entre une chambre, un emplacement expos\u00e9 et un trac\u00e9 enterr\u00e9 g\u00e9n\u00e9rique.<\/figcaption><\/figure>\n<div style=\"overflow-x:auto;\">\n<table style=\"width:100%;border-collapse:collapse;margin:20px 0;font-size:15px;line-height:1.5;\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;background:#eaf0f5;\">Emplacement<\/th>\n<th style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;background:#eaf0f5;\">Questions \u00e0 examiner<\/th>\n<th style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;background:#eaf0f5;\">Documentation \u00e0 demander<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Armoire abrit\u00e9e<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Temp\u00e9rature, condensation et acc\u00e8s pour la maintenance<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Limites de fonctionnement et d\u00e9gagement d\u2019installation<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Chambre d\u2019acc\u00e8s<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Exposition \u00e0 l\u2019eau, soutien sur le parcours et manipulations r\u00e9p\u00e9t\u00e9es<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Conditions d\u2019\u00e9tanch\u00e9it\u00e9 et configuration de protection<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Installation apparente<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Lumi\u00e8re du soleil, intemp\u00e9ries et variations de temp\u00e9rature<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Preuves d\u2019exposition sp\u00e9cifiques au mod\u00e8le<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Enfouissement direct<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Contact avec le sol, charges d\u2019installation et protection requise<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Approbation pour l\u2019ensemble enterr\u00e9 complet<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Ne supposez pas qu\u2019une protection contre un type d\u2019exposition en remplace une autre. Une certification d\u2019imperm\u00e9abilit\u00e9 ne garantit pas automatiquement la r\u00e9sistance aux UV, et une affirmation relative \u00e0 la protection contre les UV ne prouve pas la r\u00e9sistance aux charges de montage. Assurez-vous que chaque exigence puisse \u00eatre rattach\u00e9e \u00e0 la pi\u00e8ce et \u00e0 la configuration r\u00e9ellement fournies.<\/p>\n<h2>Quelles sont les dimensions du conduit qui doivent correspondre au raccord en plastique ?<\/h2>\n<p>Enregistrez le diam\u00e8tre ext\u00e9rieur, le diam\u00e8tre int\u00e9rieur, le mat\u00e9riau et la tol\u00e9rance approuv\u00e9e de chaque extr\u00e9mit\u00e9 du conduit. Un raccord droit relie g\u00e9n\u00e9ralement deux interfaces compatibles de m\u00eame dimension ; un r\u00e9ducteur n\u00e9cessite deux d\u00e9signations de dimensions distinctes. V\u00e9rifiez le passage interne lorsque l\u2019espacement des c\u00e2bles ou une transition est pertinent.<\/p>\n<p>Pour une mise \u00e0 niveau, mesurez et identifiez le conduit existant plut\u00f4t que de vous fier uniquement \u00e0 un plan ancien. Les d\u00e9formations, les dommages ou les substitutions non document\u00e9es peuvent rendre la taille nominale trompeuse. Utilisez un mat\u00e9riel de mesure fiable et v\u00e9rifiez la construction du conduit conform\u00e9ment aux sp\u00e9cifications d\u2019homologation du fabricant des raccords.<\/p>\n<p>Le <a href=\"https:\/\/microductconnector.com\/blog\/direct-buried-microduct-connector\/\">guide de fixation du connecteur microduct enterr\u00e9 directement<\/a> fournit un contexte de s\u00e9lection pertinent, mais le mod\u00e8le exact doit encore \u00eatre mis en correspondance avec l\u2019itin\u00e9raire r\u00e9el. Un composant annonc\u00e9 comme \u00e9tant destin\u00e9 \u00e0 l\u2019enfouissement n\u2019est pas automatiquement compatible avec tous les conduits pouvant \u00eatre ins\u00e9r\u00e9s dans son orifice d\u2019entr\u00e9e.<\/p>\n<h2>Quelles sont les preuves qui attestent de la r\u00e9sistance aux intemp\u00e9ries, aux UV et aux charges d\u2019un coupleur de conduit ?<\/h2>\n<p><strong>Adaptabilit\u00e9 environnementale<\/strong> Il faut plus qu\u2019une simple liste de propri\u00e9t\u00e9s mat\u00e9rielles int\u00e9ressantes. Demandez des informations concernant l\u2019exposition \u00e0 l\u2019eau, la temp\u00e9rature, l\u2019ensoleillement le cas \u00e9ch\u00e9ant, ainsi que les conditions m\u00e9caniques. Renseignez-vous sur la mani\u00e8re dont ces essais sont li\u00e9s \u00e0 la taille du connecteur, au mat\u00e9riau du conduit et aux accessoires figurant dans le devis.<\/p>\n<p>La documentation de l\u2019appareil MPB30601+ d\u2019Hexatronic constitue un exemple utile des exigences sp\u00e9cifiques \u00e0 la configuration : son utilisation en pose directe dans le sol implique une protection externe. Cela ne rend pas cette protection facultative, et cela n\u2019autorise pas l\u2019utilisation d\u2019un connecteur non prot\u00e9g\u00e9 d\u2019un autre fabricant. C\u2019est l\u2019ensemble complet, test\u00e9 ou approuv\u00e9, qui compte.<\/p>\n<figure style=\"width:50%;max-width:600px;margin:24px auto;text-align:center;\"><img alt=\"Water, UV, temperature and mechanical exposure informing evidence requests\" decoding=\"async\" height=\"800\" loading=\"lazy\" src=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/11\/plastic-duct-coupler-outdoor-selection-diagram-v2.webp\" style=\"display:block;width:100%;height:auto;border-radius:6px;\" width=\"600\"\/><figcaption style=\"font-size:14px;line-height:1.5;color:#52616d;margin-top:8px;\">Water, UV, temperature and mechanical exposure informing evidence requests.<\/figcaption><\/figure>\n<p>When a supplier cites a standard, ask for the applicable scope and report. A standard number alone does not demonstrate independent certification, coverage of every size or equivalence to another product. Record the document revision so purchasing and installation teams are using the same information.<\/p>\n<div style=\"overflow-x:auto;\">\n<table style=\"width:100%;border-collapse:collapse;margin:20px 0;font-size:15px;line-height:1.5;\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;background:#eaf0f5;\">Claim in a listing<\/th>\n<th style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;background:#eaf0f5;\">Useful follow-up question<\/th>\n<th style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;background:#eaf0f5;\">Insufficient substitute<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Water resistant<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Under what conditions and for which assembly?<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">A photograph of the part near water<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">UV resistant<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">What evidence covers this material and variant?<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Black body colour alone<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Direct buried<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Are a cover or other protective measures required?<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">The words underground in a title<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Pressure rated<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Working, proof, burst or sealing pressure?<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">An unexplained maximum number<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Tested to a standard<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Which model, method, conditions and results?<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">A standard number without supporting scope<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Where evidence is missing, request it before approving the part. Do not fill gaps by borrowing ratings from a visually similar connector. Product-specific data is especially important when a family includes several body materials, sizes or protective configurations.<\/p>\n<h2>Does the route need a duct coupler, a cable seal or both?<\/h2>\n<p>A coupler joining the outside surfaces of two ducts can leave the space around the cable open. If the route requires control of gas or water migration along that space, specify a separate sealing function. Emtelle describes its gas-block connector as sealing between connector, tube and fibre cable.<\/p>\n<p>Its gas-block datasheet also separates tube dimensions from fibre-unit or cable ranges and distinguishes gas sealing from pressure information associated with fibre installation. These distinctions matter at building entries and other defined boundaries. They do not mean that every coupler needs a gas block or that a gas block replaces a building penetration seal.<\/p>\n<p>Assess a suitable <a href=\"https:\/\/microductconnector.com\/product\/fza1412-7-10-straight-microduct-gas-block-connector-product\/\">connecteur microduct pour gaz<\/a> when the route design calls for cable-annulus sealing. Confirm cable diameter, activation sequence, location and sealed-state conditions. Do not infer those properties from the outdoor rating of the adjacent straight coupler.<\/p>\n<h2>When does a microduct coupler need a protective cover and supports?<\/h2>\n<p>An external shell can be part of a connector&#8217;s approved protective arrangement, but it cannot correct a wrong duct diameter or damaged seal. Install the specified accessory and check that it closes correctly without trapping debris or pressing a release mechanism.<\/p>\n<p>Le <a href=\"https:\/\/microductconnector.com\/blog\/microduct-cover-shell-troubleshooting\/\">Guide de d\u00e9pannage des gaines microducts<\/a> discusses common protection and fit issues. Investigate the underlying joint before covering it. If a shell repeatedly opens or does not seat, confirm the model pairing and route loading instead of improvising a fastening method.<\/p>\n<p>Support the duct to avoid continuous tension, sharp bending and unintended loads at the connector. Keep the final arrangement accessible where maintenance is expected. A well-protected body can still be undermined by a duct forced into a misaligned route or a collar pressed against nearby hardware.<\/p>\n<h2>Which connector checks should be completed before burial or enclosure?<\/h2>\n<p>Check component identity, duct dimensions, cut quality, outside sealing surfaces, insertion and retention according to the manufacturer&#8217;s instructions. Complete the route&#8217;s approved passage and leakage checks before handover. Keep them separate: a pressure-tight joint does not prove an unobstructed cable route.<\/p>\n<p>Use the project-defined pressure, duration, temperature conditions and acceptance criteria within the limits of every component in the test assembly. Check temporary adapters and closures as well as installed joints. Isolate and release pressure before making adjustments; never use a catalogue burst figure as a routine operating instruction.<\/p>\n<p>Record whether tests were completed before or after final placement. If subsequent handling, covering or burial can affect the joint, follow the project requirement for inspection or verification at that stage. A record should identify the final configuration, not just a successful bench assembly.<\/p>\n<h2>Can the existing duct coupler accommodate a future cable upgrade?<\/h2>\n<p><strong>Network maintenance planning<\/strong> begins with an identifiable joint. Record location, connector variant, duct dimensions, accessories and acceptance results. Include cable details where a reducer or cable seal makes them relevant. Future crews should be able to determine what was installed without excavating solely to identify it.<\/p>\n<p>For a hypothetical upgrade to a larger cable, an existing coupler might remain compatible with the duct outside diameter while the smaller route bore becomes limiting. A gas seal may also need replacement because of the new cable diameter. Review the whole route rather than approving the upgrade from the coupler&#8217;s external appearance.<\/p>\n<p>Follow the manufacturer&#8217;s reuse and release policy during repairs. Inspect previously gripped duct surfaces and preserve enough length for a supported replacement. If cutting back creates tension, use an approved repair arrangement rather than stretching the remaining duct into the joint.<\/p>\n<h2>What to include when requesting an outdoor duct coupler quotation<\/h2>\n<p>A useful enquiry includes both duct dimensions, cable details, installation location, water and sunlight exposure, temperature requirements, operating conditions and required documentation. State whether the quote must include covers or other accessories. This prevents two suppliers from pricing different assemblies under the same coupler name.<\/p>\n<h2>Foire aux questions<\/h2>\n<h3>Can a plastic duct coupler be used outdoors and underground?<\/h3>\n<p>Only when the exact variant and configuration are documented for the location. Distinguish exposed, chamber and direct-buried conditions. Required covers, supports and installation methods are part of the approval rather than optional extras.<\/p>\n<h3>What should be inspected on a plastic duct coupler before cable installation?<\/h3>\n<p>Check identification, dimensions, cut and surface condition, seating, retention, supports and protective accessories. Verify the approved passage and leak-test records. Investigate damage or uncertainty before cable installation rather than using the installation itself as a test.<\/p>\n<h3>How does a plastic duct coupler differ from a standard telecom coupler?<\/h3>\n<p>Plastic describes the body material, while standard telecom coupler is an imprecise category. Compare actual function, interfaces, bore, sealing, retention and environment. Two differently named products can serve the same role, while two similarly named ones can differ substantially.<\/p>\n<h3>How is a plastic duct coupler replaced during a network upgrade?<\/h3>\n<p>Plan access and isolation, follow the release instructions and inspect the remaining duct. Install a documented compatible replacement without route tension, reassess cable passage and any cable seal, then complete the specified acceptance checks and update the route record.<\/p>\n<h3>Which materials protect a coupler from moisture and UV?<\/h3>\n<p>Suitability depends on the exact formulation, seal system, configuration and exposure evidence. A broad resin name or black colour is insufficient. Request model-specific documentation rather than treating a material category as an unconditional performance guarantee.<\/p>\n<h3>Which installation errors can cause a plastic duct coupler to fail?<\/h3>\n<p>Wrong dimensions, damaged or dirty duct ends, incomplete insertion, unsupported loads, accidental release contact and missing required protection are all concerns to investigate. A site-specific examination is needed to identify the cause; appearance alone cannot establish it.<\/p>\n<h2>R\u00e9f\u00e9rences<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.hexatronic.com\/en\/fiber-solutions\/products?product=microduct-connectors-and-end-stops-mpb30601-plus-&amp;cat_id=10629\" rel=\"nofollow noopener\" target=\"_blank\">Hexatronic, connecteurs MPB30601+ et arr\u00eats de fin<\/a>: application, construction and external-cover conditions.<\/li>\n<li><a href=\"https:\/\/www.emtelle.com\/products\/microducts-tube-bundles\/microduct-connectors-accessories\/gas-block-connector\" rel=\"nofollow noopener\" target=\"_blank\">Emtelle, connecteur de bloc de gaz<\/a>: sealing around the fibre cable as a separate requirement.<\/li>\n<li><a href=\"https:\/\/www.emtelle.com\/Content\/Uploads\/UK_DS_JGGasBlock.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Emtelle, Connecteurs de blocs de gaz, num\u00e9ro 5<\/a>: separate duct and fibre interfaces and sealing information.<\/li>\n<\/ul>\n<h2>R\u00e9sum\u00e9<\/h2>\n<p>Select an outdoor duct coupler by the actual route: dimensions, cable passage, water, sunlight, temperature and mechanical exposure. Confirm the complete protective configuration and keep cable sealing separate from duct joining. Document installation and acceptance before access becomes difficult so future repairs begin with reliable information.<\/p>\n<p>Le <a href=\"https:\/\/microductconnector.com\/product\/black-straight-direct-buried-microduct-connector-micro-duct-coupler-end-stop-product\/\">black direct-buried microduct connector<\/a> is a product to assess against those requirements. Request the exact size, current installation instructions and environmental evidence. Its intended application provides a starting point, while the project-specific confirmation determines whether it belongs in the route.<\/p>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>Pr\u00e9cisez les raccords de conduits en plastique pour les armoires, les trac\u00e9s ext\u00e9rieurs et l\u2019installation enterr\u00e9e directe, en indiquant la taille, les caract\u00e9ristiques d\u2019\u00e9tanch\u00e9it\u00e9, de r\u00e9sistance aux UV, de tenue en temp\u00e9rature et les performances m\u00e9caniques requises pour le mod\u00e8le exact.<\/p>","protected":false},"author":2,"featured_media":5397,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[21],"tags":[],"class_list":["post-5414","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-insights"],"_links":{"self":[{"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/posts\/5414","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/comments?post=5414"}],"version-history":[{"count":2,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/posts\/5414\/revisions"}],"predecessor-version":[{"id":5423,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/posts\/5414\/revisions\/5423"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/media\/5397"}],"wp:attachment":[{"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/media?parent=5414"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/categories?post=5414"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/tags?post=5414"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}