{"id":5370,"date":"2026-11-01T00:00:00","date_gmt":"2026-11-01T00:00:00","guid":{"rendered":"https:\/\/microductconnector.com\/?p=5370"},"modified":"2026-10-26T07:39:54","modified_gmt":"2026-10-26T07:39:54","slug":"pu-tube-oil-water-chemical-compatibility","status":"publish","type":"post","link":"https:\/\/microductconnector.com\/fr\/blog\/pu-tube-oil-water-chemical-compatibility\/","title":{"rendered":"Choisir un tube en polyur\u00e9thane pour une exposition \u00e0 l\u2019huile, \u00e0 l\u2019eau et aux produits chimiques"},"content":{"rendered":"<article>\n<p>Imaginez un ing\u00e9nieur de maintenance \u00e0 Nottingham s\u00e9lectionnant un tube d\u2019air de remplacement \u00e0 c\u00f4t\u00e9 d\u2019une machine r\u00e9guli\u00e8rement nettoy\u00e9e. Le tube existant est flexible et facile \u00e0 positionner, aussi la commande se contente-t-elle de mentionner \u00ab tube en PU \u00bb. Quelques semaines plus tard, l\u2019\u00e9quipe constate une modification de l\u2019\u00e9tat de surface apr\u00e8s l\u2019introduction d\u2019un nouveau d\u00e9tergent. Cette situation hypoth\u00e9tique met en \u00e9vidence une sp\u00e9cification manquante : le seul nom du polym\u00e8re ne suffit pas \u00e0 garantir la compatibilit\u00e9 avec les conditions d\u2019exposition r\u00e9elles.<\/p>\n<p>A <strong>Tube en PU<\/strong> Il convient de proc\u00e9der \u00e0 une \u00e9valuation sp\u00e9cifique en fonction du fluide ou du contaminant externe concern\u00e9, de sa concentration, de la temp\u00e9rature, de la dur\u00e9e de contact et de la pression. Cette \u00e9valuation doit \u00e9galement tenir compte des raccords et des joints associ\u00e9s. La conformit\u00e9 \u00e0 l\u2019air comprim\u00e9 ne garantit pas automatiquement la compatibilit\u00e9 avec le transport continu d\u2019huile ou d\u2019eau, et une projection occasionnelle ne correspond pas aux m\u00eames conditions d\u2019utilisation qu\u2019un contact interne permanent.<\/p>\n<h2>S\u00e9parer l\u2019exposition ext\u00e9rieure du fluide transport\u00e9 \u00e0 l\u2019int\u00e9rieur du tube.<\/h2>\n<p>D\u00e9crivez l\u2019endroit o\u00f9 le produit chimique entre en contact avec le tube. Une pulv\u00e9risation externe peut n\u2019entrer en contact qu\u2019avec une partie de la paroi pendant une courte dur\u00e9e avant le rin\u00e7age ou le s\u00e9chage. Un fluide interne, lui, peut rester en contact continu, atteindre le joint d\u2019\u00e9tanch\u00e9it\u00e9 et cr\u00e9er des conditions de pression et de temp\u00e9rature diff\u00e9rentes. L\u2019immersion, les projections intermittentes, les vapeurs ainsi que le lubrifiant v\u00e9hicul\u00e9 par l\u2019air comprim\u00e9 doivent donc \u00eatre enregistr\u00e9s comme des expositions distinctes.<\/p>\n<p>Le temps de contact est aussi important que la concentration. Un produit de nettoyage jug\u00e9 inoffensif pendant un cycle de nettoyage court valid\u00e9 peut ne pas \u00eatre acceptable si des r\u00e9sidus s\u2019accumulent sous une pince. De m\u00eame, un tube qui semble inchang\u00e9 apr\u00e8s une immersion br\u00e8ve n\u2019a pas d\u00e9montr\u00e9 qu\u2019il conserve ses propri\u00e9t\u00e9s m\u00e9caniques requises tout au long de sa dur\u00e9e de service. L\u2019inspection visuelle est utile, mais elle ne constitue qu\u2019une partie des preuves d\u2019compatibilit\u00e9.<\/p>\n<figure style=\"width:50%;max-width:600px;margin:24px auto;text-align:center;\"><img alt=\"External splash and continuous internal fluid contact are different tube exposures\" decoding=\"async\" height=\"800\" loading=\"lazy\" src=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/pu-tube-oil-water-chemical-compatibility-detail.webp\" style=\"display:block;width:100%;height:auto;border-radius:6px;\" width=\"600\"\/><figcaption style=\"font-size:14px;line-height:1.5;color:#52616d;margin-top:8px;\">Les \u00e9claboussures externes et le contact continu du fluide \u00e0 l\u2019int\u00e9rieur du tube constituent des modes d\u2019exposition distincts.<\/figcaption><\/figure>\n<p>Indiquez les m\u00e9langes de mani\u00e8re pr\u00e9cise. Le terme \u00ab huile \u00bb peut d\u00e9signer diff\u00e9rents fluides de base et diff\u00e9rentes gammes d\u2019additifs ; le terme \u00ab d\u00e9tergent \u00bb peut englober de nombreuses formulations. Obtenez l\u2019identit\u00e9 du produit ainsi que les documents de s\u00e9curit\u00e9 ou techniques pertinents, plut\u00f4t que de demander l\u2019approbation pour une cat\u00e9gorie g\u00e9n\u00e9rique. Incluez le taux de dilution normal, la concentration maximale pr\u00e9vue, ainsi que tout fluide de nettoyage ou de rin\u00e7age susceptible de circuler dans la conduite lors des op\u00e9rations de maintenance.<\/p>\n<div style=\"overflow-x:auto;\">\n<table style=\"width:100%;border-collapse:collapse;margin:20px 0;font-size:15px;line-height:1.5;\">\n<caption>D\u00e9crivez l\u2019exposition avant de vous demander si le polyur\u00e9thane est adapt\u00e9.<\/caption>\n<thead>\n<tr>\n<th style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;background:#eaf0f5;\">Exposition<\/th>\n<th style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;background:#eaf0f5;\">Informations n\u00e9cessaires<\/th>\n<th style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;background:#eaf0f5;\">Pourquoi une r\u00e9ponse g\u00e9n\u00e9rique est insuffisante<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Roulement d\u2019huile du compresseur<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Identit\u00e9 du lubrifiant et contact pr\u00e9vu<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">La chimie des huiles et les additifs diff\u00e8rent.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Eau transport\u00e9e en interne<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Type d\u2019eau, temp\u00e9rature, dur\u00e9e et pression<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Les qualit\u00e9s de PU sont soumises \u00e0 diff\u00e9rentes restrictions en mati\u00e8re d\u2019eau.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Spray de nettoyage ext\u00e9rieur<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Nettoyant, dilution, temps de contact et rin\u00e7age<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Les r\u00e9sidus et la temp\u00e9rature modifient l\u2019exposition.<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">M\u00e9lange chimique<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Composition compl\u00e8te et conditions de fonctionnement<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Un diagramme relatif \u00e0 un produit chimique pur peut ne pas s\u2019appliquer.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>V\u00e9rifiez la qualit\u00e9 r\u00e9elle du polyur\u00e9thane avant d\u2019autoriser l\u2019utilisation dans des installations d\u2019eau.<\/h2>\n<p><strong>Tuyau en polyur\u00e9thane<\/strong> comprend diff\u00e9rentes formulations et structures. Une couleur ou une sensation souple ne permet pas d\u2019identifier la qualit\u00e9. Demandez au fabricant la s\u00e9rie exacte et les restrictions \u00e9crites concernant les fluides, en particulier lorsque l\u2019eau, l\u2019humidit\u00e9 ou le nettoyage \u00e0 chaud sont en jeu. Ne validez pas une application avec de l\u2019eau simplement parce qu\u2019un autre produit polyur\u00e9thane d\u2019une s\u00e9rie diff\u00e9rente y est r\u00e9f\u00e9renc\u00e9.<\/p>\n<p>Le catalogue TU de SMC en constitue un exemple concret. La section TU\/TIUB mentionne l\u2019air et l\u2019eau en pr\u00e9cisant les conditions d\u2019utilisation, tandis que la section TUH interdit l\u2019eau en raison de l\u2019hydrolyse. Il s\u2019agit d\u2019instructions propres au fabricant, et non d\u2019une \u00e9valuation de chaque formulation de polyur\u00e9thane. Elles montrent pourquoi une affirmation g\u00e9n\u00e9rale du type \u00ab le polyur\u00e9thane est \u00e9tanche \u00bb ne suffit pas pour choisir un ensemble de tube sous pression.<\/p>\n<p>Le m\u00eame document indique une pression de service maximale \u00e0 une temp\u00e9rature donn\u00e9e, ainsi que des conditions de temp\u00e9rature distinctes pour l\u2019eau. Cela confirme un second point : l\u2019homologation du fluide et les limites m\u00e9caniques doivent \u00eatre consid\u00e9r\u00e9es conjointement. Un tube peut \u00eatre adapt\u00e9 \u00e0 un fluide dans une plage d\u00e9finie sans pour autant \u00eatre compatible avec toutes les temp\u00e9ratures ou pressions mentionn\u00e9es ailleurs dans le catalogue.<\/p>\n<p>En cas de d\u00e9faillances r\u00e9currentes, conservez l\u2019emballage tubulaire, le code fournisseur et les informations sur le lot, lorsque disponibles. Comparez ces \u00e9l\u00e9ments avec le mat\u00e9riau d\u2019origine approuv\u00e9. Si la seule description enregistr\u00e9e est \u00ab PU bleu \u00bb, il peut \u00eatre impossible de d\u00e9terminer si le remplacement utilise la m\u00eame qualit\u00e9. Une description d\u2019achat plus compl\u00e8te permet de distinguer un changement de formulation d\u2019une substitution mat\u00e9rielle non intentionnelle.<\/p>\n<h2>Assess oil and chemical contact across the entire assembly<\/h2>\n<p>The tube is only one wetted component. Check the fitting body, gripping arrangement, seal and any thread-sealing material that can encounter the fluid. A stainless fitting can contain an elastomer with different chemical limits. SMC&#8217;s KQG2 fluid guidance evaluates body and seal materials separately, which is a useful reminder that metal compatibility does not establish assembly compatibility.<\/p>\n<p>Do not treat a chemical-resistance chart as a complete operating approval. Check the tested material, concentration, temperature, exposure time and the meaning of its rating. A chart based on static immersion does not necessarily establish pressure capability, fatigue life or performance of a stressed tube in motion. Where the duty is consequential, request confirmation for the actual use and a suitable qualification plan.<\/p>\n<p>Le <a href=\"https:\/\/microductconnector.com\/blog\/stainless-push-in-fittings-media-compatibility\/\">stainless fitting media compatibility guide<\/a> explains this component-by-component review. It is particularly relevant when the tube appears to survive but leakage develops at the socket. A seal response, dimensional change or tube-surface damage can affect the connection without visible corrosion of the metal body.<\/p>\n<p>Watch for swelling, softening, cracking, unusual stiffness and changes at the clamped or inserted sections. These observations should trigger investigation rather than a definitive chemical diagnosis. Remove affected components from service under the approved procedure and retain evidence where useful. Do not continue pressurized testing merely to see how long visibly degraded tubing will last.<\/p>\n<h2>Keep temperature, pressure and routing within the approved range<\/h2>\n<p><strong>Pressure-temperature limits<\/strong> are tied to the exact tube construction. The Oulu <a href=\"https:\/\/microductconnector.com\/product\/4x2-5-6x4-8x5-10x6-5-12x8-14x10-16x12-pu-air-pneumatic-tube-pipe-hose-for-air-line-polyurethane-tubing-product\/\">PU tube listing<\/a> identifies available size combinations, including 6 \u00d7 4 mm and 8 \u00d7 5 mm, and states a temperature range. That information is not a complete pressure-versus-temperature curve or a chemical-service approval. Request the missing working and bend data for the chosen variant before specifying the assembly.<\/p>\n<p>Record outside and inside diameters separately. The socket matches the approved outside diameter; the bore contributes to flow delivery. A tube with the correct outer size may still restrict a long pneumatic run if its bore is smaller than the original. Do not compensate for that change by increasing supply pressure without investigating the actual restriction and permitted operating limits.<\/p>\n<p>Routing can increase the effect of an unsuitable exposure. A tight bend, abrasion point or heavily compressed clamp creates an additional mechanical concern at the same location. Keep the line away from sharp edges and hot surfaces, provide room for motion and follow the exact minimum bend requirement. A room-temperature bend value should not be assumed to validate continuous flexing in a warm chemical environment.<\/p>\n<p>Cut and insert tubing only after safe isolation and depressurization. Use a suitable cutter, inspect the outside sealing surface and insert to the fitting&#8217;s specified position. The <a href=\"https:\/\/microductconnector.com\/blog\/pu-pneumatic-hose-leaks-kinks\/\">PU hose leak and kink guide<\/a> helps distinguish installation damage from a broader material-compatibility problem. Neither a fresh cut nor a new fitting can make an unapproved chemical duty suitable.<\/p>\n<h2>Ask for compatibility evidence that matches the real duty<\/h2>\n<p>Send a complete enquiry rather than asking whether PU resists chemicals. Include exact tube grade and dimensions, fitting and seal identity, chemical name, concentration, fluid and ambient temperatures, pressure, contact duration and whether the tube moves. State any cleaning cycle or abnormal exposure that the system is expected to tolerate. Missing information should remain an open question, not become an assumed approval.<\/p>\n<div style=\"overflow-x:auto;\">\n<table style=\"width:100%;border-collapse:collapse;margin:20px 0;font-size:15px;line-height:1.5;\">\n<caption>A practical supplier enquiry for compatibility review<\/caption>\n<thead>\n<tr>\n<th style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;background:#eaf0f5;\">Required field<\/th>\n<th style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;background:#eaf0f5;\">Example of useful information<\/th>\n<th style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;background:#eaf0f5;\">Evidence requested<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Material identity<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Exact tube series, size and fitting seal<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Matching datasheets and variant confirmation<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Chemical identity<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Named fluid and documented dilution<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Compatibility statement for that composition<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Conditions de fonctionnement<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Pressure, temperatures and contact duration<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Limits and any derating or exclusions<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Mechanical duty<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Fixed route or repeated motion<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Bend and installation requirements<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Special requirements<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Actual food contact or clean-air duty<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Documents covering the intended use<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Define the acceptance criteria before any application trial. These may include leakage, dimensional change and mechanical condition under a documented procedure, with limits agreed by the responsible engineer and supplier. A casual soak test is not certification. If food contact or clean process air is required, obtain the applicable documents for the exact material and use; a generic industrial PU listing is insufficient.<\/p>\n<figure style=\"width:50%;max-width:600px;margin:24px auto;text-align:center;\"><img alt=\"Chemical identity, concentration, temperature, contact time and material grade inform compatibility review\" decoding=\"async\" height=\"800\" loading=\"lazy\" src=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/pu-tube-oil-water-chemical-compatibility-diagram-v3.webp\" style=\"display:block;width:100%;height:auto;border-radius:6px;\" width=\"600\"\/><figcaption style=\"font-size:14px;line-height:1.5;color:#52616d;margin-top:8px;\">Chemical identity, concentration, temperature, contact time and material grade inform compatibility review.<\/figcaption><\/figure>\n<p>Keep compatibility decisions with the maintenance record so future changes can be reviewed. A new cleaner, higher temperature or different lubricant may invalidate an earlier selection even if the tube part number stays the same. The most useful approval states its conditions clearly enough that technicians can recognize when those conditions have changed.<\/p>\n<h2>Foire aux questions<\/h2>\n<h3>What tube size and bend radius should be used?<\/h3>\n<p>Select outside diameter to match the approved fitting and inside diameter to support the required flow. Use the bend limit for the exact tube size, grade and conditions. A generic PU description does not provide a universal radius or confirm suitability for repeated movement.<\/p>\n<h3>How do you prevent abrasion and kinks in PU tubing?<\/h3>\n<p>Provide supported routing with adequate bend clearance and room for machine movement. Avoid sharp edges, hot surfaces and clamps that distort the wall. Inspect the complete movement range and keep side load away from the fitting entry.<\/p>\n<h3>What pressure and temperature limits apply to a PU tube?<\/h3>\n<p>Use the exact product&#8217;s working limits and temperature-dependent restrictions, including the connected fittings and seals. Do not substitute burst pressure for working pressure. A rating quoted at room temperature may not apply at the hottest operating condition.<\/p>\n<h3>Which connector thread matches a PU tube without leaking?<\/h3>\n<p>The tube itself is matched to a socket by outside diameter, approved material and tolerance, not by a pipe thread. If the connector has a threaded equipment end, identify that port separately. Both interfaces must be correctly specified for a reliable assembly.<\/p>\n<h3>How should PU tubing be cut and inserted for a reliable seal?<\/h3>\n<p>After isolation, make a clean square cut and check that the tube is round and free of scoring. Insert it straight to the fitting manufacturer&#8217;s required position and perform the specified retention check. Replace damaged or degraded tube rather than reusing an unsuitable sealing surface.<\/p>\n<h3>Can a PU tube carry oil, water or chemicals?<\/h3>\n<p>Only where the exact grade and complete assembly are approved for the named medium and conditions. Water restrictions can differ even between polyurethane series from the same manufacturer. Obtain written compatibility confirmation covering concentration, temperature, pressure and contact duration.<\/p>\n<h2>R\u00e9f\u00e9rences<\/h2>\n<ul>\n<li><a href=\"https:\/\/content2.smcetech.com\/pdf\/TU.pdf\" rel=\"nofollow noopener\" target=\"_blank\">SMC: TU, TIUB and TUH fluid and temperature precautions<\/a><\/li>\n<li><a href=\"https:\/\/content2.smcetech.com\/pdf\/KQG2.pdf\" rel=\"nofollow noopener\" target=\"_blank\">SMC: KQG2 body and seal fluid guidance<\/a><\/li>\n<li><a href=\"https:\/\/content2.smcetech.com\/pdf\/KQ2.pdf\" rel=\"nofollow noopener\" target=\"_blank\">SMC: KQ2 fitting and tube selection information<\/a><\/li>\n<\/ul>\n<h2>R\u00e9sum\u00e9<\/h2>\n<p>PU compatibility depends on a defined material meeting a defined exposure, not on the polymer name alone. Check the fluid, concentration, temperature, duration and mechanical duty, then include every wetted seal and fitting in the decision. For an Oulu <a href=\"https:\/\/microductconnector.com\/product\/4x2-5-6x4-8x5-10x6-5-12x8-14x10-16x12-pu-air-pneumatic-tube-pipe-hose-for-air-line-polyurethane-tubing-product\/\">polyurethane tube quotation<\/a>, provide that operating information with the required OD and ID so the proposed product can be checked against the intended service before installation.<\/p>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>\u00c9valuez l\u2019exposition des tuyaux en PU \u00e0 l\u2019huile, \u00e0 l\u2019eau et aux produits chimiques en tenant compte de la qualit\u00e9 du polym\u00e8re, de la temp\u00e9rature, de la concentration et de la compatibilit\u00e9 des joints, \u00e0 l\u2019aide d\u2019une liste de contr\u00f4le pratique.<\/p>","protected":false},"author":2,"featured_media":5355,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[21],"tags":[],"class_list":["post-5370","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-insights"],"_links":{"self":[{"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/posts\/5370","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/comments?post=5370"}],"version-history":[{"count":1,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/posts\/5370\/revisions"}],"predecessor-version":[{"id":5371,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/posts\/5370\/revisions\/5371"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/media\/5355"}],"wp:attachment":[{"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/media?parent=5370"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/categories?post=5370"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/tags?post=5370"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}