{"id":4062,"date":"2026-03-24T10:00:00","date_gmt":"2026-03-24T10:00:00","guid":{"rendered":"https:\/\/microductconnector.com\/blog\/splice-boxes-enhance-efficiency-in-blown-fiber-optic-installations\/"},"modified":"2026-10-23T09:42:48","modified_gmt":"2026-10-23T09:42:48","slug":"splice-boxes-enhance-efficiency-in-blown-fiber-optic-installations","status":"publish","type":"post","link":"https:\/\/microductconnector.com\/fr\/blog\/splice-boxes-enhance-efficiency-in-blown-fiber-optic-installations\/","title":{"rendered":"Comment les bo\u00eetes d'\u00e9pissure am\u00e9liorent l'efficacit\u00e9 dans les installations de fibre optique souffl\u00e9e"},"content":{"rendered":"<article>\n<p>A <strong>bo\u00eete de raccordement<\/strong> constitue un point de r\u00e9ception de l\u2019installation et un espace de maintenance futur. Il doit prot\u00e9ger le joint tout en permettant aux techniciens d\u2019identifier les fibres, d\u2019acc\u00e9der au plateau appropri\u00e9 et de r\u00e9tablir l\u2019\u00e9tanch\u00e9it\u00e9 sp\u00e9cifi\u00e9e. Dans un r\u00e9seau \u00e0 fibres achemin\u00e9es par soufflage, cela implique de planifier l\u2019entr\u00e9e des c\u00e2bles, <strong>stockage en retard<\/strong> et la r\u00e9introduction avant de s\u00e9lectionner un coffret en fonction du nombre de fibres indiqu\u00e9 dans son intitul\u00e9.<\/p>\n<p>Une bo\u00eete de raccordement am\u00e9liore l\u2019efficacit\u00e9 du tirage de fibres lorsque sa configuration d\u2019entr\u00e9e de c\u00e2bles, sa gestion des plateaux, sa m\u00e9thode d\u2019\u00e9tanch\u00e9it\u00e9 et son mode d\u2019acc\u00e8s correspondent \u00e0 l\u2019itin\u00e9raire et au plan de maintenance du r\u00e9seau. \u00c0 chaque transition, prot\u00e9gez le joint, respectez les rayons de courbure sp\u00e9cifi\u00e9s pour les fibres et gardez les identifiants de fibre facilement accessibles. IEC 61300 est une famille de m\u00e9thodes d\u2019essai des composants, et non une approbation globale de chaque enceinte. Sp\u00e9cifiez l\u2019enceinte et ses accessoires avant l\u2019installation, puis v\u00e9rifiez l\u2019ensemble install\u00e9 conform\u00e9ment aux exigences applicables du projet.<\/p>\n<h2>Pourquoi l\u2019acc\u00e8s aux bo\u00eetiers de raccordement influence le temps d\u2019installation<\/h2>\n<p>Une installation de fibres a\u00e9riennes s\u00e9pare le trac\u00e9 civil de l\u2019op\u00e9ration de pose du c\u00e2ble : les microtubes sont install\u00e9s en premier, puis les unit\u00e9s de fibre sont introduites ult\u00e9rieurement \u00e0 l\u2019aide d\u2019un \u00e9quipement pneumatique. Ce mod\u00e8le par \u00e9tapes peut acc\u00e9l\u00e9rer le d\u00e9ploiement, mais il rend \u00e9galement les points de raccordement particuli\u00e8rement critiques. Chaque emplacement de jonction doit permettre aux techniciens de terminer, d\u2019identifier et de tester les fibres, ainsi que de r\u00e9int\u00e9grer ult\u00e9rieurement la liaison sans perturber les fibres adjacentes.<\/p>\n<figure class=\"wp-block-image size-full\" style=\"width:50%;max-width:600px;margin:1.5rem auto\"><img alt=\"Inspection of the visible interfaces on Factory supply fiber optic communication equipment fiber optic splice closure dome closure 144 core D96-04\" class=\"wp-image-4977\" decoding=\"async\" height=\"800\" loading=\"lazy\" src=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/repair59-4062-inline1.webp\" style=\"width:100%;height:auto;display:block\" width=\"600\" srcset=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/repair59-4062-inline1.webp 600w, https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/repair59-4062-inline1-225x300.webp 225w, https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/repair59-4062-inline1-9x12.webp 9w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<p>L\u2019entr\u00e9e, la disposition des plateaux, le stockage du surplus de c\u00e2ble et les joints d\u2019\u00e9tanch\u00e9it\u00e9 influent tous sur la dur\u00e9e d\u2019installation et de maintenance. Une conception pratique prend en compte au moins quatre interfaces \u2014 entr\u00e9e de conduits ou de c\u00e2bles, plateau d\u2019\u00e9pissure, stockage du surplus de c\u00e2ble et \u00e9tanch\u00e9it\u00e9 \u2014 car un d\u00e9faut \u00e0 l\u2019une de ces interfaces peut transformer une courte intervention de service en une op\u00e9ration plus longue d\u2019excavation, de manipulation des c\u00e2bles ou de retest. La g\u00e9om\u00e9trie de la fibre compte \u00e9galement : les normes ITU-T G.652 et G.657 d\u00e9crivent les caract\u00e9ristiques des fibres monomodes, tandis que les limites r\u00e9elles de courbure pour un c\u00e2ble ou une unit\u00e9 de fibre s\u00e9lectionn\u00e9s doivent \u00eatre tir\u00e9es de la documentation fournie par leur fabricant.<\/p>\n<h3>Pourquoi les visites de suivi augmentent-elles les co\u00fbts des bo\u00eetiers de raccordement ?<\/h3>\n<p>Une seconde visite peut r\u00e9v\u00e9ler des probl\u00e8mes d\u2019acc\u00e8s et d\u2019\u00e9tiquetage pass\u00e9s inaper\u00e7us lors de l\u2019installation. Si les identifiants sont illisibles, si les plateaux ne peuvent pas \u00eatre soulev\u00e9s sans contrainte, ou si un composant d\u2019\u00e9tanch\u00e9it\u00e9 ne correspond pas aux diam\u00e8tres d\u2019arriv\u00e9e, les techniciens perdent du temps \u00e0 retracer les fibres et \u00e0 r\u00e9p\u00e9ter les tests optiques. Par exemple, deux techniciens suppl\u00e9mentaires mobilis\u00e9s pour une intervention de deux heures repr\u00e9sentent quatre heures-homme, sans compter les co\u00fbts de d\u00e9placement, de gestion du trafic, de remise en \u00e9tat ou les retards clients. Une cartographie claire des plateaux et une s\u00e9quence d\u2019installation reproductible permettent de limiter ces risques ; les essais de r\u00e9ception doivent suivre le plan d\u2019essai contractuel, incluant g\u00e9n\u00e9ralement la continuit\u00e9 optique et les mesures de perte.<\/p>\n<h2>Enregistrer les changements de plateau et les tests optiques apr\u00e8s la r\u00e9ouverture d\u2019un colis<\/h2>\n<p>Une d\u00e9faillance optique survenue ult\u00e9rieurement peut \u00eatre difficile \u00e0 diagnostiquer si le bo\u00eetier a \u00e9t\u00e9 ouvert sans documentation claire. Avant tout travail planifi\u00e9, identifiez les fibres et les services concern\u00e9s, enregistrez la carte actuelle des plateaux et suivez la proc\u00e9dure d\u2019acc\u00e8s de l\u2019op\u00e9rateur. \u00c9vitez de perturber des circuits non concern\u00e9s simplement pour rendre l\u2019agencement plus soign\u00e9. Si la disposition sur site diff\u00e8re du sch\u00e9ma, v\u00e9rifiez l\u2019identification avant d\u2019effectuer un raccord ou de repositionner le surplus de c\u00e2ble.<\/p>\n<p>Apr\u00e8s les travaux autoris\u00e9s, mettez \u00e0 jour la configuration r\u00e9elle des ports et des plateaux, et inspectez le dispositif d\u2019\u00e9tanch\u00e9it\u00e9 conform\u00e9ment aux sp\u00e9cifications du fabricant de l\u2019enveloppe. Enregistrez tous les joints, accessoires remplac\u00e9s ou pi\u00e8ces endommag\u00e9es, ainsi que les d\u00e9tails de l\u2019installation utilis\u00e9s. Les preuves relatives \u00e0 l\u2019environnement s\u2019appliquent \u00e0 une configuration compl\u00e8te : un r\u00e9sultat obtenu pour un port et une disposition de c\u00e2bles ne doit pas \u00eatre transmis implicitement \u00e0 une autre m\u00e9thode d\u2019entr\u00e9e. Ne pr\u00e9sentez pas un test de pression ou un contr\u00f4le optique comme une preuve d\u2019une classe de protection IP non prise en charge.<\/p>\n<p>Conserver <strong>preuve optique<\/strong> distinct de la qualit\u00e9 de l\u2019assemblage. L\u2019Association de la fibre optique explique qu\u2019un OTDR permet de localiser les \u00e9v\u00e9nements et de comparer les r\u00e9sultats avec une trace de r\u00e9f\u00e9rence, tandis que la perte d\u2019insertion directe est mesur\u00e9e \u00e0 l\u2019aide d\u2019une source lumineuse et d\u2019un puiss\u00e9m\u00e8tre. Utilisez le plan de test d\u00e9fini dans le contrat et associez \u00e0 chaque r\u00e9sultat les identifiants des fibres, les points d\u2019extr\u00e9mit\u00e9 et les param\u00e8tres utilis\u00e9s. Une diff\u00e9rence nette entre une trace r\u00e9alis\u00e9e avant et apr\u00e8s les travaux peut orienter les investigations ; elle ne permet pas \u00e0 elle seule d\u2019identifier toutes les causes m\u00e9caniques \u00e0 l\u2019int\u00e9rieur du bo\u00eetier.<\/p>\n<p>Pour les travaux FTTH en phase progressive, joignez la fiche d\u2019enclosure mise \u00e0 jour au m\u00eame syst\u00e8me de route et d\u2019adresse utilis\u00e9 pour l\u2019activation. Le <a href=\"https:\/\/microductconnector.com\/blog\/what-is-ftth-the-role-of-microduct-connectors-in-ftth\/\">Article sur la planification FTTH<\/a> explique pourquoi un itin\u00e9raire passif achev\u00e9 se distingue d\u2019un service client provisionn\u00e9. Associez l\u2019enregistrement conjoint au guide d\u2019itin\u00e9raire des microconduits et aux microconduits en PEHD s\u00e9lectionn\u00e9s, afin que les travaux futurs puissent suivre \u00e0 la fois le trajet optique et le parcours physique. L\u2019utilisation des m\u00eames identifiants aide les techniciens \u00e0 localiser le conduit, la bo\u00eete de raccordement et la fibre lors des interventions ult\u00e9rieures.<\/p>\n<h2>Comparez les bo\u00eetiers en fonction des t\u00e2ches qu\u2019ils doivent assurer.<\/h2>\n<p>Le bon choix est celui qui soutient la strat\u00e9gie d\u2019acc\u00e8s du r\u00e9seau, plut\u00f4t que l\u2019armoire la plus grande figurant sur une page de catalogue. Le tableau ci-dessous compare les approches de planification courantes ; il n\u2019attribue pas de capacit\u00e9s ou de classifications environnementales universelles, celles-ci d\u00e9pendant du produit exact et de la configuration install\u00e9e.<\/p>\n<figure class=\"wp-block-image size-full\" style=\"width:50%;max-width:600px;margin:1.5rem auto\"><img alt=\"Visible surface and connection-end preparation detail for HDPE Microduct Distribution Closure\" class=\"wp-image-4979\" decoding=\"async\" height=\"800\" loading=\"lazy\" src=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/repair59-4062-inline2.webp\" style=\"width:100%;height:auto;display:block\" width=\"600\" srcset=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/repair59-4062-inline2.webp 600w, https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/repair59-4062-inline2-225x300.webp 225w, https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/repair59-4062-inline2-9x12.webp 9w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<table>\n<thead>\n<tr>\n<th>Approche de planification<\/th>\n<th>Avantage op\u00e9rationnel<\/th>\n<th>Risque d\u2019efficacit\u00e9 \u00e0 ma\u00eetriser<\/th>\n<th>Meilleure question d\u2019approvisionnement<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Point de distribution compact<\/td>\n<td>Chemin de traitement plus court pour les t\u00e2ches courantes en agence<\/td>\n<td>L'espace de travail limit\u00e9 peut ralentir les modifications futures.<\/td>\n<td>La disposition du plateau peut-elle supporter le nombre d\u2019acc\u00e8s pr\u00e9vu ?<\/td>\n<\/tr>\n<tr>\n<td>Emplacement du joint \u00e0 haut acc\u00e8s<\/td>\n<td>R\u00e9int\u00e9gration organis\u00e9e pour la croissance et la restauration des pannes<\/td>\n<td>Plus de pi\u00e8ces peuvent entra\u00eener davantage de variables d\u2019installation.<\/td>\n<td>Quels joints, ports et accessoires sont inclus pour l\u2019itin\u00e9raire r\u00e9el ?<\/td>\n<\/tr>\n<tr>\n<td>Transition entre les sections du parcours<\/td>\n<td>D\u00e9finit les responsabilit\u00e9s et les limites des tests<\/td>\n<td>Un mauvais \u00e9tiquetage entra\u00eene des retards dans le tra\u00e7age.<\/td>\n<td>Comment les identifiants de route, les identifiants de fibre et les enregistrements de test seront-ils conserv\u00e9s ?<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Dimensionnez le point d\u2019\u00e9pissure en fonction de l\u2019acc\u00e8s et du nombre de fibres.<\/h2>\n<p>Une sp\u00e9cification de bo\u00eete de raccordement pour fibres optiques doit commencer par la description de l\u2019environnement d\u2019installation : mur int\u00e9rieur, chambre, poteau, socle ou installation enterr\u00e9e ; le c\u00e2ble d\u2019arriv\u00e9e et <a href=\"https:\/\/microductconnector.com\/hdpe-microducts\/\">Construction de conduits<\/a>; and the expected change frequency. Fiber count remains important, but it is only one of several dimensions. Procurement teams should ask for documented compatible ranges and installation instructions rather than infer fit from a photograph.<\/p>\n<table>\n<thead>\n<tr>\n<th>Dimension de s\u00e9lection<\/th>\n<th>Quoi documenter<\/th>\n<th>Why it improves field efficiency<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Route architecture<\/td>\n<td>Feeder, distribution, branch, and reserve paths<\/td>\n<td>Prevents a handover point from becoming an unplanned bottleneck.<\/td>\n<\/tr>\n<tr>\n<td>Entry and sealing<\/td>\n<td>Incoming types, diameters, ports, and sealing procedure<\/td>\n<td>Avoids mismatched components and repeat visits.<\/td>\n<\/tr>\n<tr>\n<td>Fiber management<\/td>\n<td>Tray count, routing path, slack method, and labeling convention<\/td>\n<td>Helps protect bend control and speeds identification.<\/td>\n<\/tr>\n<tr>\n<td>Maintenance model<\/td>\n<td>Expected re-entry, tools, records, and access permissions<\/td>\n<td>Aligns enclosure design with actual restoration work.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Those choices also affect the rest of the pathway. Compatible <a href=\"https:\/\/microductconnector.com\/blog\/role-of-microduct-fittings-in-fiber-optic-installations\/\">connecteurs pour microconduits<\/a> help preserve a controlled duct route, while selected HDPE microducts should be considered as part of the same pathway and installation plan.<\/p>\n<h2>Check access to each tray before filling the enclosure<\/h2>\n<p>Nominal splice capacity does not establish whether a technician can reach a particular fibre after the enclosure is populated. Review the actual <strong>tray sequence<\/strong>, stored slack, cable entry and closure method for the supplied configuration. Use the manufacturer\u2019s cable and fibre routing instructions, including the relevant bend limits, rather than applying one remembered radius to every buffer tube, bare fibre and jacketed cable in the box.<\/p>\n<p>During design review, identify which tray will be opened for a later connection and what must move to reach it. Check that the intended operation does not place tension on a live fibre or require an uncontrolled bend at the tray hinge. Reserve the space and accessories needed for the defined expansion plan. An empty port or an unused position on a drawing is not sufficient if the installed cable and slack already obstruct the access path.<\/p>\n<p>Confirm that the duct-to-cable transition is planned. A cable installed by air assistance must be handled, secured and routed using the approved instructions after it reaches the access point. Do not assume that the enclosure is a pressurised blowing manifold or that its lid can be left open during a process it was not designed to support. The <a href=\"https:\/\/microductconnector.com\/blowing-machines\/\">blowing equipment page<\/a> helps identify the separate installation stage; the enclosure documentation defines its own cable-entry and sealing arrangement.<\/p>\n<p>Make the first completed assembly a controlled workmanship example when the project requires one. Record port use, tray identifiers, fibre assignments, slack location and the instructions used. A proposed re-entry review can then ask whether the next technician can identify and access the required fibre without disturbing neighbouring services. Treat that as a project acceptance check, not as a claim that a particular enclosure has passed an undocumented universal serviceability test.<\/p>\n<h2>Which standards cover splice-closure tests and performance<\/h2>\n<p>Check the scope of the cited standard and the tested enclosure configuration. The IEC 61300 series specifies test and measurement procedures for fiber-optic interconnecting devices and passive components; a cited IEC 61300 method describes how a stated characteristic is evaluated, not automatic certification of a complete installed assembly. IEC 61753 provides performance-standard frameworks for passive fiber-optic components, while Telcordia GR-771 is widely used as a generic requirement reference for fiber-optic splice closures in telecommunications applications.<\/p>\n<p>For fiber compatibility and system planning, ITU-T G.652 and G.657 address optical fiber characteristics. They do not, by themselves, validate enclosure sealing, installation quality, or local safety requirements. The applicable evidence depends on the destination market, installation environment, customer specification, and every claim made in a tender or product sheet. Unsupported IP, capacity, or certification claims create commercial risk: they can trigger submittal rejection, retesting, or disputes over responsibility.<\/p>\n<p>A practical buying checklist for contractors and OSP teams:<\/p>\n<ol>\n<li>Map each splice point to the route drawing and identify whether it is a one-time joint or a likely re-entry location.<\/li>\n<li>Request installation instructions, compatible accessory lists, and test evidence that is specific to the offered configuration.<\/li>\n<li>Confirm fiber routing, slack storage, labels, and the technician\u2019s working sequence before field deployment.<\/li>\n<li>Retain acceptance records with route identifiers.<\/li>\n<\/ol>\n<p>ANMASPC \/ Microduct Connector can support this specification stage by helping buyers align pathway components, connection hardware, and cable-blowing equipment documentation with the intended installation process. Request the drawings, accessory list and instructions that installers will need to assemble and later reopen the enclosure.<\/p>\n<h2>Foire aux questions<\/h2>\n<h3>What is a fiber optic splice box?<\/h3>\n<p>A fiber optic splice box is an enclosure and fiber-management system that protects and organizes spliced optical fibers at a network joint or distribution point. Its suitability depends on the cable types, environment, access needs, and installation instructions for the specific assembly.<\/p>\n<h3>What is the difference between a splice box and a splice closure?<\/h3>\n<p>A splice closure generally emphasizes environmental protection around a fiber joint, whereas \u201csplice box\u201d is often used for an enclosure that also emphasizes organized access and distribution. Market terminology varies, so buyers should compare the supplier\u2019s drawings, sealing method, and approved application instead of relying on the name alone.<\/p>\n<h3>Why are splice boxes used in blown fiber installation?<\/h3>\n<p>They provide a controlled point for joining, identifying, testing, and managing fibers where a blown-fiber route transitions or branches. In a growing fiber network, that organization can reduce re-entry time and lower the chance of disturbing live circuits.<\/p>\n<h3>How do you choose a fiber optic splice box?<\/h3>\n<p>Start with the route architecture, incoming cable and duct details, expected fiber management, environmental exposure, and maintenance model. Then verify the exact configuration against installation instructions and the project\u2019s required test evidence.<\/p>\n<h3>Can a splice box be used outdoors?<\/h3>\n<p>Some enclosure configurations are intended for outdoor use, but outdoor suitability must be confirmed from the manufacturer\u2019s documentation for the installed ports, seals, and mounting arrangement. Check the project\u2019s environmental exposure and local requirements before specifying it.<\/p>\n<h3>How many fibers can a splice box hold?<\/h3>\n<p>Capacity varies by enclosure, tray design, splice type, cable construction, and reserve-space requirement. Use the supplier\u2019s documented capacity for configuration, and leave management space for the access plan rather than selecting by a headline count.<\/p>\n<h3>What evidence should be requested for an outdoor splice enclosure?<\/h3>\n<p>Request the applicable environmental test scope, sealing and cable-entry instructions, fiber capacity and bend limits, mounting details, identification method, re-entry procedure and replacement-part information for the exact model.<\/p>\n<h3>Does the advertised splice count guarantee room for later additions?<\/h3>\n<p>No. Usable expansion depends on the installed cable entries, tray layout, slack storage, accessories and access sequence. Check the populated configuration and manufacturer\u2019s instructions, then reserve the space required by the actual expansion plan.<\/p>\n<h3>What should be recorded after opening and resealing a splice closure?<\/h3>\n<p>Retain the route and closure IDs, changed fibre assignments, port and tray configuration, replaced seals or accessories, inspection result and the optical tests required by the contract. Keep test endpoints and settings so a later technician can compare like with like.<\/p>\n<h2>R\u00e9f\u00e9rences<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.thefoa.org\/tech\/ref\/testing\/OTDR\/OTDR.html\" rel=\"nofollow noopener\" target=\"_blank\">Association de la fibre optique \u2014 R\u00e9flectom\u00e8tre optique dans le domaine temporel : analyse des \u00e9v\u00e9nements versus mesure des pertes d\u2019insertion<\/a><\/li>\n<\/ul>\n<h2>R\u00e9sum\u00e9<\/h2>\n<p>A splice point needs accessible trays, readable fibre identifiers and a sealing arrangement that technicians can restore after maintenance. Select the enclosure with its actual cable entries, tray sequence, slack requirements and sealing arrangement in view. Confirm the relevant bend limits from the supplied documentation, and review how a later tray operation will affect neighbouring fibres. After re-entry, update the port and fibre map, record replaced sealing parts and retain the required optical results against the same route identifiers. Keep enclosure workmanship, environmental evidence and optical acceptance distinct. These records help technicians identify the affected fibre and inspect the work completed at the last visit.<\/p>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>Apprenez comment des bo\u00eetiers d'\u00e9pissure correctement sp\u00e9cifi\u00e9s r\u00e9duisent les travaux de r\u00e9intervention, prot\u00e8gent les \u00e9pissures de fibres et maintiennent l'efficacit\u00e9 des projets d'installation de fibres souffl\u00e9es.<\/p>","protected":false},"author":2,"featured_media":5286,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[21],"tags":[],"class_list":["post-4062","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-insights"],"_links":{"self":[{"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/posts\/4062","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/comments?post=4062"}],"version-history":[{"count":9,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/posts\/4062\/revisions"}],"predecessor-version":[{"id":5058,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/posts\/4062\/revisions\/5058"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/media\/5286"}],"wp:attachment":[{"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/media?parent=4062"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/categories?post=4062"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/tags?post=4062"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}