{"id":4058,"date":"2026-03-20T10:00:00","date_gmt":"2026-03-20T10:00:00","guid":{"rendered":"https:\/\/microductconnector.com\/blog\/ultimate-guide-to-choosing-plastic-air-ducts\/"},"modified":"2026-10-23T09:42:49","modified_gmt":"2026-10-23T09:42:49","slug":"ultimate-guide-to-choosing-plastic-air-ducts","status":"publish","type":"post","link":"https:\/\/microductconnector.com\/fr\/blog\/ultimate-guide-to-choosing-plastic-air-ducts\/","title":{"rendered":"Guide ultime pour le choix des conduits d'air en plastique pour les installations de fibre optique et de r\u00e9seaux"},"content":{"rendered":"<article>\n<p>Dans une sp\u00e9cification d\u2019installation de fibres, \u201c<strong>conduit d\u2019air en plastique<\/strong>\u201d devrait d\u00e9signer le chemin de c\u00e2bles utilis\u00e9 pour une installation assist\u00e9e par air, et non un conduit de CVC ou une conduite d\u2019eau sous pression. D\u00e9finissez clairement cet usage avant de comparer les produits. Le c\u00e2ble, l\u2019al\u00e9sage r\u00e9el, <strong>g\u00e9om\u00e9trie de la route<\/strong>, Le syst\u00e8me de raccordement et la proc\u00e9dure de r\u00e9ception d\u00e9terminent si la voie est adapt\u00e9e \u00e0 l\u2019installation pr\u00e9vue.<\/p>\n<p>Choisissez le conduit en fonction de la m\u00e9thode d\u2019installation des c\u00e2bles, de la g\u00e9om\u00e9trie du trac\u00e9 et du plan de gestion des eaux, en veillant \u00e0 ce qu\u2019il dispose du diam\u00e8tre utile requis. Pour les r\u00e9seaux \u00e0 fibre optique souffl\u00e9e, v\u00e9rifiez la lissitude de l\u2019al\u00e9sage et le contr\u00f4le des courbures avant de comparer les prix. Examinez les exigences applicables aux conduits pour c\u00e2bles en parall\u00e8le avec les instructions d\u2019installation du fournisseur. Sp\u00e9cifiez conjointement le conduit, les raccords, les joints d\u2019extr\u00e9mit\u00e9 et les essais d\u2019acceptation, puis confirmez les dimensions document\u00e9es avant le d\u00e9marrage des travaux.<\/p>\n<h2>D\u00e9finissez le type de c\u00e2ble et la m\u00e9thode d\u2019installation.<\/h2>\n<p>Ces conduits d\u2019air en plastique sont des gaines polym\u00e8res qui constituent un chemin prot\u00e9g\u00e9 \u00e0 faible friction pour l\u2019installation de c\u00e2bles ou de fibres optiques \u00e0 l\u2019aide d\u2019air comprim\u00e9. Dans les travaux de t\u00e9l\u00e9communications, ils peuvent \u00eatre des conduits enterr\u00e9s directement, des sous-conduits \u00e0 l\u2019int\u00e9rieur de conduits plus grands, ou des microconduits permettant d\u2019augmenter ult\u00e9rieurement la capacit\u00e9.<\/p>\n<figure class=\"wp-block-image size-full\" style=\"width:50%;max-width:600px;margin:1.5rem auto\"><img alt=\"Inspection of the visible interfaces on 7 Ways 12\/10 mm DB HDPE Tube\" class=\"wp-image-4974\" decoding=\"async\" height=\"800\" loading=\"lazy\" src=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/repair59-4058-inline1.webp\" style=\"width:100%;height:auto;display:block\" width=\"600\" srcset=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/repair59-4058-inline1.webp 600w, https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/repair59-4058-inline1-225x300.webp 225w, https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/repair59-4058-inline1-9x12.webp 9w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<p>D\u00e9terminez d\u2019abord si la conduite transportera de l\u2019\u00e9lectricit\u00e9, des c\u00e2bles de communication ou des microc\u00e2bles pos\u00e9s par soufflage a\u00e9rien. Un corridor de services publics peut privil\u00e9gier la r\u00e9sistance \u00e0 l\u2019\u00e9crasement et la traction des c\u00e2bles ; un r\u00e9seau d\u2019acc\u00e8s fibre optique privil\u00e9gie g\u00e9n\u00e9ralement un diam\u00e8tre int\u00e9rieur contr\u00f4l\u00e9, une surface int\u00e9rieure \u00e0 faible friction et la continuit\u00e9 du parcours. La norme IEC 61386-24 sp\u00e9cifie les exigences et les essais applicables aux syst\u00e8mes de conduites enterr\u00e9es ; son champ d\u2019application ne garantit pas une distance de soufflage particuli\u00e8re ni l\u2019aptitude \u00e0 toutes les conditions de sol.<\/p>\n<p>La g\u00e9om\u00e9trie du parcours impose une contrainte suppl\u00e9mentaire. Enregistrez le diam\u00e8tre int\u00e9rieur, la longueur, le rayon de courbure, les variations d\u2019\u00e9l\u00e9vation, les points d\u2019acc\u00e8s et le diam\u00e8tre ext\u00e9rieur du c\u00e2ble. Le c\u00e2ble doit conserver un espace annulaire suffisant pour la circulation de l\u2019air ; les recommandations du fabricant concernant le rapport c\u00e2ble\/gaine doivent donc d\u00e9terminer le ratio final. Si le diam\u00e8tre ext\u00e9rieur du c\u00e2ble approche celui de la gaine, il se peut que le jeu disponible ne soit pas conforme \u00e0 la m\u00e9thode pr\u00e9vue ; n\u2019acceptez pas un couple c\u00e2ble-gaine de diam\u00e8tres \u00e9gaux comme solution de soufflage viable.<\/p>\n<h2>Diff\u00e9rencier le conduit de c\u00e2bles du tuyau sous pression et du chemin int\u00e9rieur.<\/h2>\n<p>Les produits en PEHD sont con\u00e7us pour des applications vari\u00e9es, notamment les canalisations sous pression et la protection de c\u00e2bles. Une canalisation sous pression est sp\u00e9cifi\u00e9e pour transporter le fluide pr\u00e9vu selon les exigences r\u00e9gissant son utilisation ; un conduit pour c\u00e2bles assure leur protection et leur gestion ; un cheminement int\u00e9rieur doit satisfaire aux prescriptions applicables en mati\u00e8re de construction et d\u2019installation. La m\u00eame famille de polym\u00e8res peut \u00eatre utilis\u00e9e dans ces trois contextes sans que les produits finis ne soient interchangeables. V\u00e9rifiez l\u2019utilisation d\u00e9clar\u00e9e et la documentation pour identifier pr\u00e9cis\u00e9ment le produit.<\/p>\n<p>Pour les chemins de c\u00e2bles enterr\u00e9s, le domaine d\u2019application officiel IEC 61386-24 couvre les syst\u00e8mes de conduits et les raccords de conduits destin\u00e9s \u00e0 la protection et \u00e0 la gestion des conducteurs ou c\u00e2bles isol\u00e9s dans les installations \u00e9lectriques ou les syst\u00e8mes de communication. Il inclut les syst\u00e8mes m\u00e9talliques, non m\u00e9talliques et composites. Ce domaine d\u2019application aide \u00e0 identifier la cat\u00e9gorie appropri\u00e9e, mais il ne publie pas de ratio universel c\u00e2ble\/duct et ne certifie aucun r\u00e9sultat de tirage en service fourni par un fournisseur particulier. Veuillez examiner s\u00e9par\u00e9ment les preuves produits d\u00e9clar\u00e9es et les exigences du projet.<\/p>\n<p>Pour une installation assist\u00e9e par air, procurez-vous le <strong>al\u00e9sage utilisable<\/strong>, OD, tol\u00e9rances, restrictions d\u2019itin\u00e9raire, d\u00e9tails des joints et les approuv\u00e9s <strong>appairage du c\u00e2ble<\/strong>. Une paroi de tuyau sous pression ou une taille nominale de tuyau ne sauraient remplacer ces champs. Une paroi plus \u00e9paisse peut modifier la section utile pour l\u2019\u00e9coulement \u00e0 diam\u00e8tre ext\u00e9rieur (DE) constant, tandis qu\u2019un raccord con\u00e7u pour un autre DE ou une autre construction risque de ne pas assurer un serrage ni une \u00e9tanch\u00e9it\u00e9 corrects. Veuillez consulter le <a href=\"https:\/\/microductconnector.com\/hdpe-microducts\/\">Options de microconduits en PEHD<\/a> avec les informations r\u00e9elles sur le c\u00e2ble et les raccords, plut\u00f4t que de consid\u00e9rer tous les tubes en poly\u00e9thyl\u00e8ne comme \u00e9quivalents.<\/p>\n<p>Lors d\u2019une transition entre l\u2019ext\u00e9rieur et l\u2019int\u00e9rieur, v\u00e9rifiez pr\u00e9cis\u00e9ment l\u2019emplacement o\u00f9 se termine le produit ext\u00e9rieur et o\u00f9 commence le cheminement int\u00e9rieur ou l\u2019am\u00e9nagement d\u2019entr\u00e9e. Confirmez les exigences en mati\u00e8re de r\u00e9sistance au feu et de travers\u00e9e avec le concepteur responsable. Ne reportez pas une classification d\u2019enterr\u00e9 sur une demande de r\u00e9sistance au feu en milieu int\u00e9rieur, et n\u2019utilisez pas un essai de pression d\u2019air pour justifier une performance coupe-feu. Consignez s\u00e9par\u00e9ment les exigences relatives \u00e0 l\u2019enterr\u00e9, \u00e0 l\u2019entr\u00e9e et \u00e0 l\u2019int\u00e9rieur, puis v\u00e9rifiez le produit propos\u00e9 \u00e0 chaque emplacement.<\/p>\n<h2>Adaptez le mat\u00e9riau du conduit \u00e0 la m\u00e9thode d\u2019installation.<\/h2>\n<p>Les microconduits en PEHD sont couramment choisis car le poly\u00e9thyl\u00e8ne haute densit\u00e9 allie flexibilit\u00e9, r\u00e9sistance aux chocs, r\u00e9sistance \u00e0 la corrosion et une paroi interne lisse. Tenez compte de l\u2019ensemble : paroi du conduit, couche interne \u00e0 faible coefficient de frottement lorsque sp\u00e9cifi\u00e9e, raccords, joints et dispositifs d\u2019\u00e9tanch\u00e9it\u00e9. Une irr\u00e9gularit\u00e9, une section ovale ou une fuite d\u2019air au niveau d\u2019un raccord peuvent entraver le passage du c\u00e2ble, m\u00eame si le conduit lui-m\u00eame est conforme \u00e0 la sp\u00e9cification.<\/p>\n<figure class=\"wp-block-image size-full\" style=\"width:50%;max-width:600px;margin:1.5rem auto\"><img alt=\"D\u00e9tail de pr\u00e9paration de la surface visible et des extr\u00e9mit\u00e9s de raccordement pour le tuyau micro-conduit en PEHD 1 \u00e0 1 voie\" class=\"wp-image-4976\" decoding=\"async\" height=\"800\" loading=\"lazy\" src=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/repair59-4058-inline2.webp\" style=\"width:100%;height:auto;display:block\" width=\"600\" srcset=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/repair59-4058-inline2.webp 600w, https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/repair59-4058-inline2-225x300.webp 225w, https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/10\/repair59-4058-inline2-9x12.webp 9w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<p>Pour une liaison \u00e0 fibres insuffl\u00e9es, le confinement de l\u2019air et la gestion des frottements agissent de concert. Les fuites r\u00e9duisent la pression dans le c\u00e2ble ; les asp\u00e9rit\u00e9s, les d\u00e9bris et les courbures trop serr\u00e9es augmentent la r\u00e9sistance. Les variations de temp\u00e9rature peuvent influencer les dimensions du conduit et provoquer des mouvements de la voie ; suivez les recommandations d\u2019installation et de retenue fournies par le fabricant du conduit plut\u00f4t que d\u2019en d\u00e9duire une marge universelle. Les sp\u00e9cifications doivent pr\u00e9ciser la pression, la politique en mati\u00e8re de lubrifiant, les proc\u00e9dures de nettoyage et les essais de v\u00e9rification.<\/p>\n<p>Le conduit pr\u00e9sentant le co\u00fbt unitaire le plus bas peut entra\u00eener le co\u00fbt de pose le plus \u00e9lev\u00e9 s\u2019il n\u00e9cessite des puits d\u2019acc\u00e8s, la r\u00e9cup\u00e9ration du c\u00e2ble ou des travaux de reprise apr\u00e8s un tirage infructueux. \u00c0 titre illustratif, \u00e9viter une excavation suppl\u00e9mentaire et un retour d\u2019\u00e9quipe peut compenser une \u00e9conomie modeste sur les mat\u00e9riaux. Int\u00e9grez la capacit\u00e9 d\u2019extension, la fiabilit\u00e9 des raccords, les longueurs de livraison et la tra\u00e7abilit\u00e9 dans l\u2019analyse du co\u00fbt total.<\/p>\n<table>\n<caption>Comparaison des chemins de c\u00e2bles pour les fibres et les r\u00e9seaux techniques<\/caption>\n<thead>\n<tr>\n<th>D\u00e9marche<\/th>\n<th>Meilleur ajustement<\/th>\n<th>Performance d\u2019installation<\/th>\n<th>Tendance de la maintenance et du TCO<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Grand conduit technique<\/td>\n<td>Services mixtes ou c\u00e2bles tir\u00e9s<\/td>\n<td>Space for subducts; performance depends on internal condition<\/td>\n<td>Higher civil material footprint, but can support future segregation<\/td>\n<\/tr>\n<tr>\n<td>Single HDPE duct<\/td>\n<td>Dedicated cable route<\/td>\n<td>Flexible routing; verify bore and bend control<\/td>\n<td>Moderate initial cost; replacement can be disruptive if capacity is exhausted<\/td>\n<\/tr>\n<tr>\n<td>Multiway microduct bundle<\/td>\n<td>FTTx expansion and staged connections<\/td>\n<td>Separate pathways help isolate later installations<\/td>\n<td>Often higher initial specification effort, with lower disruption for adds and changes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Size the pathway from cable, air, and route constraints<\/h2>\n<p>Size the duct using the cable dimensions, usable bore and route conditions. Start with the supplier\u2019s measured inside diameter and cable manufacturer\u2019s maximum outside diameter, then account for couplers, bends, and the <a href=\"https:\/\/microductconnector.com\/blowing-machines\/\">\u00e9quipement de soufflage<\/a>\u2019s operating window. Longer routes generally benefit from stable bore control and fewer joints. Before a long blow, prove the route with a mandrel and clean it with a duct-sized sponge or swab.<\/p>\n<p>For direct burial, specify depth, warning tape, markers, and crossing protection according to local authority and network-owner rules. BICSI\u2019s Outside Plant Design reference treats pathway planning as a coordinated civil, cable, and access design problem. A conduit standard does not replace local excavation safety rules or manufacturer installation limits.<\/p>\n<table>\n<caption>Selection matrix by route condition<\/caption>\n<thead>\n<tr>\n<th>\u00c9tat de la route<\/th>\n<th>Ce qu\u2019il faut pr\u00e9ciser<\/th>\n<th>Pre-installation check<\/th>\n<th>Primary risk controlled<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Short internal or campus run<\/td>\n<td>Compatible bore, fire\/building requirements where applicable, accessible terminations<\/td>\n<td>Measure path and inspect bends<\/td>\n<td>Cable damage at fittings<\/td>\n<\/tr>\n<tr>\n<td>Long underground fiber run<\/td>\n<td>Continuous reel lengths where feasible, sealed joints, route records<\/td>\n<td>Mandrel, swab, and air-leak check<\/td>\n<td>Blowing loss and costly re-entry<\/td>\n<\/tr>\n<tr>\n<td>Wet ground or flood-prone area<\/td>\n<td>Water-blocking end caps, gas\/water-tight connectors as required, protected chambers<\/td>\n<td>Inspect every termination and enclosure interface<\/td>\n<td>Ingress and debris migration<\/td>\n<\/tr>\n<tr>\n<td>Future-capacity corridor<\/td>\n<td>Spare microducts, clear labels, documented occupancy<\/td>\n<td>Confirm spare paths remain capped and traceable<\/td>\n<td>Repeat excavation<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Requalify the route when cable, bends or air supply change<\/h2>\n<p>A successful blowing trial describes the tested combination, not every later job on the route. Keep the cable identity and OD, duct bore and construction, route length, bend arrangement, joins, lubricant policy and machine setup with the result. Record compressor delivery and treatment at the relevant operating conditions; a maximum pressure label alone does not describe the air supply available during installation.<\/p>\n<p>Review the trial when a change affects resistance, clearance or air delivery. Examples include a different cable construction, a new reducer, an added bend, a repaired or flattened duct section, a changed lubricant, or a different compressor and hose arrangement. Engineering should decide which section and acceptance checks must be repeated. A minor administrative change does not automatically require a new trial, but an unrecorded physical change should not be assumed harmless.<\/p>\n<p>Plumettaz\u2019s IWCS 2021 test-guideline abstract highlights how bend-only test trajectories and speed behaviour can influence comparisons, and recommends controlling the end condition of a test. Its example settings belong to that test discussion; they are not operating instructions for every duct or machine. The practical lesson is to retain the route and test method, then make changes visible before comparing results or transferring an approval.<\/p>\n<p>When a route is re-opened, inspect accessible ends and joints for ingress or disturbance and use the approved continuity, cleaning and leakage checks. The <a href=\"https:\/\/microductconnector.com\/blog\/role-of-microduct-fittings-in-fiber-optic-installations\/\">microduct fitting guide<\/a> connects those joint checks to route preparation. Compare cable blowing machines only after the pathway and utilities have been defined, so a blocked duct or inadequate air delivery is not mistaken for an equipment limitation. Keep revised acceptance evidence with the current route drawing.<\/p>\n<h2>Check the requirements for buried cable conduit<\/h2>\n<p>Standards should improve procurement clarity, not become marketing shorthand. IEC 61386-24 addresses underground conduit systems for cable protection and management. A resin classification, pipe designation or a single laboratory test is not approval of an entire installed cable route. In the United States, OSHA excavation requirements are worker-safety rules, not duct-performance standards.<\/p>\n<p>Unsupported claims such as \u201cwaterproof,\u201d \u201cstandards compliant,\u201d or \u201csuitable for all blown fiber\u201d can trigger rejected submittals or corrective work. State the destination market, environment, cable method, and test evidence required. Ask for batch identification, dimensional tolerances, and connector compatibility records.<\/p>\n<h2>What to confirm before ordering a plastic duct<\/h2>\n<ol>\n<li>Map the route and assign every section an installation method, cable size, bend limit, and environmental exposure.<\/li>\n<li>Specify measured bore, wall construction, reel length, connector type, end sealing, and evidence needed for acceptance.<\/li>\n<li>Check that fittings retain a smooth pathway; compatible microduct connectors should be selected as part of the duct system, not after delivery.<\/li>\n<li>Plan a documented <a href=\"https:\/\/microductconnector.com\/blog\/the-development-and-role-of-microduct-connectors-in-communications-in-2025\/\">duct installation acceptance<\/a> process: visual inspection, route proving, cleaning, and a pressure or leakage check where the cable method requires it.<\/li>\n<\/ol>\n<p>ANMASPC \/ Microduct Connector supports buyers needing configurable pathways, fittings, and documentation. For compressed-air work, review fiber blowing machines against duct and cable sizes before deployment.<\/p>\n<h2>Foire aux questions<\/h2>\n<h3>What are plastic air ducts used for?<\/h3>\n<p>They create a protected pathway for installing and replacing fiber, communications cable, or selected utility cables. In fiber projects, the pathway can support air-assisted installation and later network expansion; the planned cable method determines the duct construction and accessories.<\/p>\n<h3>Why is HDPE used for microducts?<\/h3>\n<p>HDPE offers useful flexibility, toughness, and resistance to many common environmental exposures while providing a suitable base material for smooth microduct pathways. Buyers should still verify the actual system dimensions, joint design, and application evidence rather than relying on the resin name alone.<\/p>\n<h3>What size duct is needed for air-blown fiber?<\/h3>\n<p>The correct size depends on the cable outside diameter, blower capability, route length, and bends. Use the cable and equipment manufacturers\u2019 compatibility guidance, then validate the real inside diameter and route condition before the production blow.<\/p>\n<h3>Can fiber be installed in an existing plastic duct?<\/h3>\n<p>Often yes, if the duct is continuous, clean, dry enough, and large enough for the cable and airflow or pulling arrangement. Survey and prove it first; crushed sections, debris, or unsealed chambers may need remediation.<\/p>\n<h3>How do you prevent water from entering a duct?<\/h3>\n<p>Seal open ends, select compatible connectors and closures, and protect chamber interfaces from standing water and debris. The effective solution is route-wide: one uncapped spare duct or poorly seated connector can compromise an otherwise well-specified system.<\/p>\n<h3>What is the difference between a duct and a microduct?<\/h3>\n<p>A duct is the broader protective conduit category, often sized for one or more cables or subducts. A microduct is a smaller, purpose-designed pathway\u2014frequently bundled with others\u2014for placing microcables and preserving spare capacity in fiber networks.<\/p>\n<h3>Can a larger nominal duct always carry more fiber?<\/h3>\n<p>Not necessarily. Usable performance also depends on cable-to-bore fit, bend profile, surface condition, joint alignment, air sealing and the approved installation method. Confirm the pairing with route measurements and a representative test.<\/p>\n<h3>What should be checked before using a plastic duct for air-assisted installation?<\/h3>\n<p>Check continuity, bore condition, water or debris, bend and access points, duct and cable compatibility, connector sealing, air supply limits and the records required for the installation handover.<\/p>\n<h3>Is a pressure-rated HDPE water pipe automatically suitable as a blowing duct?<\/h3>\n<p>No. Pressure-pipe service does not establish the cable passage, friction, joining details or installation window needed for air-blown cable. Verify the intended cable-duct application, dimensions, cable pairing and project acceptance evidence for the exact product.<\/p>\n<h3>Does a successful route test remain valid after changing the cable or compressor?<\/h3>\n<p>It may require review. Compare the new cable, duct geometry, air delivery and setup with the tested configuration. If the change affects clearance, friction, route resistance or available air, agree an appropriate requalification before relying on the previous result.<\/p>\n<h2>R\u00e9f\u00e9rences<\/h2>\n<ul>\n<li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/5417\" rel=\"nofollow noopener\" target=\"_blank\">CEI 61386-24:2004 \u2014 Syst\u00e8mes de conduits enterr\u00e9s, champ d'application officiel<\/a><\/li>\n<li><a href=\"https:\/\/www.plumettaz.com\/fr\/knowledge\/8F9B48774A99FF8AC12588F6003181A4\" rel=\"nofollow noopener\" target=\"_blank\">Griffioen et Jonker \/ Plumettaz \u2014 Lignes directrices pour la r\u00e9alisation d'essais de soufflage de c\u00e2bles, r\u00e9sum\u00e9 de l'IWCS 2021<\/a><\/li>\n<\/ul>\n<h2>R\u00e9sum\u00e9<\/h2>\n<p>Choose a plastic cable duct from its intended service, measured geometry and installation method. HDPE material alone does not make a pressure pipe, buried cable conduit and indoor pathway interchangeable. Verify the usable bore, cable pairing, connector compatibility, bends, exposure and acceptance procedure together. Keep the tested route and air-supply configuration with the result, and review that evidence when physical conditions change. Treat underground conduit requirements, product data, blowing trials and building-entry protection as distinct parts of the specification. Keep dimensions, cable pairing, joint details and trial results in the route record so purchasing and installation teams can check the same configuration.<\/p>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>S\u00e9lectionnez les conduits d\u2019air en plastique pour les installations de fibres et de services publics en fonction de la taille des c\u00e2bles, des limites de courbure, de l\u2019installation par soufflage d\u2019air, de l\u2019exposition \u00e0 l\u2019eau, de l\u2019acc\u00e8s au parcours et de la r\u00e9sistance au HDPE.<\/p>","protected":false},"author":2,"featured_media":5288,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[21],"tags":[],"class_list":["post-4058","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-insights"],"_links":{"self":[{"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/posts\/4058","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/comments?post=4058"}],"version-history":[{"count":9,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/posts\/4058\/revisions"}],"predecessor-version":[{"id":5057,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/posts\/4058\/revisions\/5057"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/media\/5288"}],"wp:attachment":[{"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/media?parent=4058"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/categories?post=4058"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/microductconnector.com\/fr\/wp-json\/wp\/v2\/tags?post=4058"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}