{"id":4080,"date":"2026-04-03T10:00:00","date_gmt":"2026-04-03T10:00:00","guid":{"rendered":"https:\/\/microductconnector.com\/blog\/optic-fiber-the-principle-of-fiber-optic-communication-fiber-optic-technology-advantages\/"},"modified":"2026-10-23T09:42:40","modified_gmt":"2026-10-23T09:42:40","slug":"optic-fiber-the-principle-of-fiber-optic-communication-fiber-optic-technology-advantages","status":"publish","type":"post","link":"https:\/\/microductconnector.com\/fa\/blog\/optic-fiber-the-principle-of-fiber-optic-communication-fiber-optic-technology-advantages\/","title":{"rendered":"\u0627\u0631\u062a\u0628\u0627\u0637\u0627\u062a \u0641\u06cc\u0628\u0631 \u0646\u0648\u0631\u06cc: \u0686\u06af\u0648\u0646\u0647 \u06a9\u0627\u0631 \u0645\u06cc\u200c\u06a9\u0646\u062f \u0648 \u0686\u0631\u0627 \u0627\u0647\u0645\u06cc\u062a \u062f\u0627\u0631\u062f"},"content":{"rendered":"<article>\n<p><strong class=\"blog-core-keyword\">\u0627\u0631\u062a\u0628\u0627\u0637 \u0641\u06cc\u0628\u0631 \u0646\u0648\u0631\u06cc<\/strong> \u0648\u0627\u0628\u0633\u062a\u0647 \u0628\u0647 \u06cc\u06a9 \u0641\u0631\u0633\u062a\u0646\u062f\u0647\u060c \u0645\u0633\u06cc\u0631 \u0641\u06cc\u0628\u0631 \u0648 \u06af\u06cc\u0631\u0646\u062f\u0647 \u0645\u0637\u0627\u0628\u0642 \u0628\u0627 \u0647\u0645 \u0627\u0633\u062a. \u0638\u0631\u0641\u06cc\u062a \u0648 \u062f\u0627\u0645\u0646\u0647 \u06a9\u0627\u0631\u0628\u0631\u062f \u0622\u0646 \u062a\u0646\u0647\u0627 \u0632\u0645\u0627\u0646\u06cc \u0645\u0641\u06cc\u062f \u0627\u0633\u062a \u06a9\u0647 \u062a\u062c\u0647\u06cc\u0632\u0627\u062a\u060c \u0633\u0627\u062e\u062a\u0627\u0631 \u06a9\u0627\u0628\u0644\u060c \u0627\u062a\u0635\u0627\u0644\u200c\u0647\u0627 \u0648 \u0645\u062d\u062f\u0648\u062f\u06cc\u062a\u200c\u0647\u0627\u06cc \u0646\u0635\u0628 \u0628\u0627 \u0647\u0645 \u0645\u0646\u0637\u0628\u0642 \u0628\u0627\u0634\u0646\u062f. \u062f\u0631\u06a9 \u0645\u0633\u06cc\u0631 \u0633\u06cc\u06af\u0646\u0627\u0644 \u0647\u0645\u0686\u0646\u06cc\u0646 \u062d\u0644 \u06cc\u06a9 \u0645\u0634\u06a9\u0644 \u0627\u0632 \u062f\u0633\u062a \u0631\u0641\u062a\u0646 \u0633\u06cc\u06af\u0646\u0627\u0644 \u0646\u0648\u0631\u06cc \u0631\u0627 \u0627\u0632 \u06cc\u06a9 \u0645\u0633\u06cc\u0631 \u0622\u0633\u06cc\u0628\u200c\u062f\u06cc\u062f\u0647\u060c \u06cc\u06a9 \u0631\u0627\u0628\u0637 \u0646\u0627\u0633\u0627\u0632\u06af\u0627\u0631 \u06cc\u0627 \u06cc\u06a9 \u062a\u0633\u062a \u067e\u0630\u06cc\u0631\u0634 \u0646\u0627\u0642\u0635\u060c \u0622\u0633\u0627\u0646\u200c\u062a\u0631 \u0645\u06cc\u200c\u06a9\u0646\u062f.<\/p>\n<p> \u0627\u0631\u062a\u0628\u0627\u0637 \u0641\u06cc\u0628\u0631 \u0646\u0648\u0631\u06cc\u060c \u0627\u0637\u0644\u0627\u0639\u0627\u062a \u0631\u0627 \u0631\u0648\u06cc \u0646\u0648\u0631 \u06a9\u062f\u06af\u0630\u0627\u0631\u06cc \u0645\u06cc\u200c\u06a9\u0646\u062f \u0648 \u0622\u0646 \u0631\u0627 \u062f\u0631 \u0637\u0648\u0644 \u06cc\u06a9 \u0641\u06cc\u0628\u0631 \u0646\u0648\u0631\u06cc \u0647\u062f\u0627\u06cc\u062a \u0645\u06cc\u200c\u06a9\u0646\u062f\u061b \u06af\u06cc\u0631\u0646\u062f\u0647\u200c\u0647\u0627 \u0633\u06cc\u06af\u0646\u0627\u0644 \u0648\u0627\u0631\u062f\u0647 \u0631\u0627 \u062f\u0648\u0628\u0627\u0631\u0647 \u0628\u0647 \u062f\u0627\u062f\u0647\u200c\u0647\u0627\u06cc \u0627\u0644\u06a9\u062a\u0631\u06cc\u06a9\u06cc \u062a\u0628\u062f\u06cc\u0644 \u0645\u06cc\u200c\u06a9\u0646\u0646\u062f. \u0645\u062f \u0648\u0627\u062d\u062f \u0648 \u0645\u062f \u0686\u0646\u062f\u06af\u0627\u0646\u0647\u060c \u0627\u0646\u062a\u062e\u0627\u0628\u200c\u0647\u0627\u06cc \u0637\u0631\u0627\u062d\u06cc \u0645\u062a\u0645\u0627\u06cc\u0632 \u0647\u0633\u062a\u0646\u062f\u060c \u0646\u0647 \u06af\u0648\u0646\u0647\u200c\u0647\u0627\u06cc \u06cc\u06a9 \u06a9\u0627\u0628\u0644 \u0642\u0627\u0628\u0644 \u0639\u0648\u0636 \u06a9\u0631\u062f\u0646: ITU-T G.652 \u0628\u0647 \u0641\u06cc\u0628\u0631 \u0645\u062f \u0648\u0627\u062d\u062f \u0645\u06cc\u200c\u067e\u0631\u062f\u0627\u0632\u062f\u060c \u062f\u0631 \u062d\u0627\u0644\u06cc \u06a9\u0647 ITU-T G.651.1 \u0628\u0647 \u0641\u06cc\u0628\u0631 \u0645\u062f \u0686\u0646\u062f\u06af\u0627\u0646\u0647 \u0628\u0627 \u0634\u0627\u062e\u0635 \u062a\u062f\u0631\u06cc\u062c\u06cc 50\/125 \u00b5m \u067e\u0648\u0634\u0634 \u0645\u06cc\u200c\u062f\u0647\u062f. \u0628\u0631 \u0627\u0633\u0627\u0633 \u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u0648 \u0628\u0631\u0646\u0627\u0645\u0647 \u0641\u0627\u0635\u0644\u0647 \u0627\u0646\u062a\u062e\u0627\u0628 \u06a9\u0646\u06cc\u062f\u060c \u0633\u067e\u0633 \u0644\u06cc\u0646\u06a9 \u0631\u0627 \u0645\u0633\u062a\u0646\u062f \u06a9\u0646\u06cc\u062f-<strong class=\"blog-core-keyword\">\u0628\u0648\u062f\u062c\u0647 \u0636\u0631\u0631<\/strong> \u0648 \u0645\u0633\u06cc\u0631 \u0646\u0635\u0628\u200c\u0634\u062f\u0647 \u0631\u0627 \u0622\u0632\u0645\u0627\u06cc\u0634 \u06a9\u0646\u06cc\u062f\u060c \u0628\u0647 \u062c\u0627\u06cc \u0627\u06cc\u0646\u06a9\u0647 \u062a\u0646\u0647\u0627 \u0628\u0647 \u0628\u0631\u0686\u0633\u0628 \u06a9\u0627\u0628\u0644 \u062a\u06a9\u06cc\u0647 \u06a9\u0646\u06cc\u062f.<\/p>\n<h2>\u0686\u06af\u0648\u0646\u06af\u06cc \u0627\u0646\u062a\u0642\u0627\u0644 \u062f\u0627\u062f\u0647 \u062a\u0648\u0633\u0637 \u0641\u0631\u0633\u062a\u0646\u062f\u0647\u200c\u0647\u0627\u060c \u0641\u06cc\u0628\u0631\u0647\u0627 \u0648 \u06af\u06cc\u0631\u0646\u062f\u0647\u200c\u0647\u0627<\/h2>\n<p>\u06cc\u06a9 \u0627\u0631\u0633\u0627\u0644\u200c\u06a9\u0646\u0646\u062f\u0647\u060c \u0645\u0646\u0628\u0639 \u0646\u0648\u0631 \u0631\u0627 \u0628\u0647 \u06af\u0648\u0646\u0647\u200c\u0627\u06cc \u062a\u063a\u06cc\u06cc\u0631 \u0645\u06cc\u200c\u062f\u0647\u062f \u06a9\u0647 \u0646\u0645\u0627\u06cc\u0646\u06af\u0631 \u062f\u0627\u062f\u0647\u200c\u0647\u0627 \u0628\u0627\u0634\u062f. \u0646\u0648\u0631 \u062f\u0631 \u0647\u0633\u062a\u0647 \u0641\u06cc\u0628\u0631 \u062d\u0631\u06a9\u062a \u0645\u06cc\u200c\u06a9\u0646\u062f\u060c \u06a9\u0647 \u0636\u0631\u06cc\u0628 \u0627\u0646\u0643\u0633\u0627\u0631 \u0622\u0646 \u0627\u0632 \u067e\u0648\u0634\u0634 \u0627\u0637\u0631\u0627\u0641\u06cc \u0628\u0627\u0644\u0627\u062a\u0631 \u0627\u0633\u062a\u061b \u062f\u0631 \u0632\u0627\u0648\u06cc\u0647\u200c\u0647\u0627\u06cc \u0645\u062c\u0627\u0632 \u0641\u06cc\u0628\u0631\u060c \u0627\u0646\u0639\u06a9\u0627\u0633 \u06a9\u0644\u06cc \u062f\u0627\u062e\u0644\u06cc \u0628\u0647 \u0645\u062d\u062f\u0648\u062f \u0634\u062f\u0646 \u0646\u0648\u0631 \u06a9\u0645\u06a9 \u0645\u06cc\u200c\u06a9\u0646\u062f. \u062f\u0631 \u0627\u0646\u062a\u0647\u0627\u06cc \u062f\u06cc\u06af\u0631\u060c \u06cc\u06a9 \u06af\u06cc\u0631\u0646\u062f\u0647 \u0646\u0648\u0631\u06cc \u0633\u06cc\u06af\u0646\u0627\u0644 \u0631\u0627 \u062a\u0634\u062e\u06cc\u0635 \u0645\u06cc\u200c\u062f\u0647\u062f. \u0644\u0627\u06cc\u0647 \u0645\u062d\u0627\u0641\u0638 \u0648 \u0633\u0627\u062e\u062a\u0627\u0631 \u06a9\u0627\u0628\u0644 \u0628\u0631\u0627\u06cc \u0646\u06cc\u0627\u0632\u0647\u0627\u06cc \u0645\u06a9\u0627\u0646\u06cc\u06a9\u06cc \u0648 \u0645\u062d\u06cc\u0637\u06cc \u0637\u0631\u0627\u062d\u06cc \u0634\u062f\u0647\u200c\u0627\u0646\u062f\u060c \u0627\u0645\u0627 \u062e\u0648\u062f \u0622\u0646\u0647\u0627 \u0647\u0633\u062a\u0647 \u0631\u0627\u0647\u0646\u0645\u0627\u06cc \u0646\u0648\u0631 \u0646\u06cc\u0633\u062a\u0646\u062f.<\/p>\n<p>\u0627\u06cc\u0646 \u062a\u0648\u0636\u06cc\u062d \u0645\u0641\u06cc\u062f \u0627\u0633\u062a\u060c \u0627\u0645\u0627 \u0628\u0647 \u0627\u06cc\u0646 \u0645\u0639\u0646\u0627 \u0646\u06cc\u0633\u062a \u06a9\u0647 \u0647\u0631 \u067e\u0631\u062a\u0648\u06cc \u0627\u0631\u0633\u0627\u0644\u200c\u0634\u062f\u0647 \u0628\u062f\u0648\u0646 \u0641\u0642\u062f\u0627\u0646 \u0633\u0641\u0631 \u0645\u06cc\u200c\u06a9\u0646\u062f. \u062c\u0630\u0628\u060c \u067e\u0631\u0627\u06a9\u0646\u062f\u06af\u06cc\u060c \u062e\u0645\u200c\u0647\u0627\u06cc \u0628\u0632\u0631\u06af\u060c \u062e\u0645\u200c\u0647\u0627\u06cc \u06a9\u0648\u0686\u06a9\u060c \u0627\u062a\u0635\u0627\u0644\u0627\u062a \u0648 \u0631\u0627\u0628\u0637\u200c\u0647\u0627\u06cc \u06a9\u0646\u06a9\u062a\u0648\u0631 \u0645\u06cc\u200c\u062a\u0648\u0627\u0646\u0646\u062f \u0633\u06cc\u06af\u0646\u0627\u0644 \u0631\u0633\u06cc\u062f\u0647 \u0628\u0647 \u06af\u06cc\u0631\u0646\u062f\u0647 \u0631\u0627 \u06a9\u0627\u0647\u0634 \u062f\u0647\u0646\u062f. \u0645\u0646\u0628\u0639 \u0641\u0646\u06cc \u0627\u0646\u062c\u0645\u0646 \u0641\u06cc\u0628\u0631 \u0646\u0648\u0631\u06cc (FOA) \u0645\u062a\u0645\u0627\u06cc\u0632 \u0645\u06cc\u200c\u06a9\u0646\u062f \u0628\u06cc\u0646 \u06a9\u0627\u0647\u0634 \u0641\u06cc\u0628\u0631 \u0648 \u0632\u06cc\u0627\u0646\u200c\u0647\u0627\u06cc \u0627\u062a\u0635\u0627\u0644 \u0648 \u0646\u0635\u0628. \u0628\u0648\u062f\u062c\u0647 \u0644\u06cc\u0646\u06a9 \u062a\u0645\u0627\u0645 \u0627\u06cc\u0646 \u0639\u0648\u0627\u0645\u0644 \u0631\u0627 \u062f\u0631 \u0646\u0638\u0631 \u0645\u06cc\u200c\u06af\u06cc\u0631\u062f\u060c \u0648 \u0645\u0634\u062e\u0635\u0627\u062a \u0645\u0631\u0628\u0648\u0637\u0647 \u0641\u0631\u0633\u062a\u0646\u062f\u0647-\u06af\u06cc\u0631\u0646\u062f\u0647 \u062d\u062f \u0645\u062c\u0627\u0632 \u0627\u0646\u062a\u0647\u0627\u06cc \u0628\u0647 \u0627\u0646\u062a\u0647\u0627\u06cc \u0631\u0627 \u062a\u0639\u06cc\u06cc\u0646 \u0645\u06cc\u200c\u06a9\u0646\u062f.<\/p>\n<p>\u0641\u06cc\u0628\u0631 \u0646\u0648\u0631\u06cc \u0646\u06cc\u0632 \u062a\u0646\u0647\u0627 \u0628\u062e\u0634\u06cc \u0627\u0632 \u06cc\u06a9 \u0633\u06cc\u0633\u062a\u0645 \u0627\u0631\u062a\u0628\u0627\u0637\u0627\u062a \u0627\u0633\u062a. \u0627\u0631\u0633\u0627\u0644\u200c\u06a9\u0646\u0646\u062f\u0647\u200c\u0647\u0627\u060c \u062f\u0631\u06cc\u0627\u0641\u062a\u200c\u06a9\u0646\u0646\u062f\u0647\u200c\u0647\u0627\u060c \u0627\u062a\u0635\u0627\u0644\u0627\u062a\u060c \u0646\u0642\u0627\u0637 \u0627\u062a\u0635\u0627\u0644 \u0648 \u0645\u0633\u06cc\u0631 \u0628\u0627\u06cc\u062f \u0628\u0647\u200c\u0637\u0648\u0631 \u0647\u0645\u0627\u0647\u0646\u06af \u0637\u0631\u0627\u062d\u06cc \u0634\u062f\u0647 \u0648 \u0628\u0627 \u0647\u0645 \u06a9\u0627\u0631 \u06a9\u0646\u0646\u062f. \u0628\u0631\u0627\u06cc \u0645\u0642\u0627\u06cc\u0633\u0647\u200c\u0627\u06cc \u06af\u0633\u062a\u0631\u062f\u0647\u200c\u062a\u0631 \u0628\u06cc\u0646 \u0627\u06cc\u0646 \u0631\u0633\u0627\u0646\u0647 \u0627\u0646\u062a\u0642\u0627\u0644 \u0648 \u06a9\u0627\u0628\u0644\u200c\u0647\u0627\u06cc \u0641\u0644\u0632\u06cc\u060c \u0628\u0647 \u0645\u0631\u0627\u062c\u0639\u0647 \u06a9\u0646\u06cc\u062f: <a href=\"https:\/\/microductconnector.com\/blog\/why-fiber-optic-transmission-instead-of-cable-transmission\/\">\u0686\u0631\u0627 \u0627\u0646\u062a\u0642\u0627\u0644 \u0641\u06cc\u0628\u0631 \u0646\u0648\u0631\u06cc \u0627\u0633\u062a\u0641\u0627\u062f\u0647 \u0645\u06cc\u200c\u0634\u0648\u062f<\/a>; \u061b \u0645\u0632\u0627\u06cc\u0627\u06cc \u0622\u0646 \u0647\u0645\u0686\u0646\u0627\u0646 \u0628\u0647 \u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u0648 \u0646\u062d\u0648\u0647 \u0646\u0635\u0628 \u0628\u0631\u0646\u0627\u0645\u0647 \u0628\u0633\u062a\u06af\u06cc \u062f\u0627\u0631\u062f.<\/p>\n<figure class=\"wp-block-image\" style=\"width:50%;max-width:600px;margin:1.5rem auto\"><img alt=\"Fiber optic connector in an outdoor network\" decoding=\"async\" loading=\"lazy\" src=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/09\/1001-fiber-optic-connector-featured.webp\" style=\"width:100%;height:auto;display:block\"\/><\/figure>\n<h2>\u062d\u0627\u0644\u062a \u0641\u06cc\u0628\u0631 \u0631\u0627 \u0628\u0627 \u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u0648 \u0641\u0627\u0635\u0644\u0647 \u0647\u0645\u0627\u0647\u0646\u06af \u06a9\u0646\u06cc\u062f<\/h2>\n<p>\u0641\u06cc\u0628\u0631 \u062a\u06a9\u200c\u0645\u062f\u060c \u06cc\u06a9 \u0645\u062f\u0644 \u0627\u0635\u0644\u06cc \u0627\u0646\u062a\u0634\u0627\u0631 \u0631\u0627 \u067e\u0634\u062a\u06cc\u0628\u0627\u0646\u06cc \u0645\u06cc\u200c\u06a9\u0646\u062f \u0648 \u0645\u0639\u0645\u0648\u0644\u0627\u064b \u0628\u0631\u0627\u06cc \u0645\u0633\u06cc\u0631\u0647\u0627\u06cc \u0645\u062e\u0627\u0628\u0631\u0627\u062a\u06cc \u0637\u0648\u0644\u0627\u0646\u06cc\u200c\u062a\u0631 \u0627\u0646\u062a\u062e\u0627\u0628 \u0645\u06cc\u200c\u0634\u0648\u062f\u061b \u0641\u06cc\u0628\u0631 \u0686\u0646\u062f\u0645\u062f\u06cc \u0627\u0645\u06a9\u0627\u0646 \u0648\u062c\u0648\u062f \u0686\u0646\u062f\u06cc\u0646 \u0645\u062f \u0631\u0627 \u0641\u0631\u0627\u0647\u0645 \u0645\u06cc\u200c\u0622\u0648\u0631\u062f \u0648 \u062f\u0631 \u067e\u06cc\u0648\u0646\u062f\u0647\u0627\u06cc\u06cc \u0627\u0633\u062a\u0641\u0627\u062f\u0647 \u0645\u06cc\u200c\u0634\u0648\u062f \u06a9\u0647 \u062f\u0633\u062a\u0631\u0633\u06cc \u0648 \u0637\u0631\u062d \u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u0622\u0646\u200c\u0647\u0627 \u0628\u0627 \u0648\u06cc\u0698\u06af\u06cc\u200c\u0647\u0627\u06cc \u0622\u0646 \u0633\u0627\u0632\u06af\u0627\u0631 \u0627\u0633\u062a. \u0627\u0646\u062a\u062e\u0627\u0628 \u0645\u062f \u0627\u062f\u0639\u0627 \u0646\u06cc\u0633\u062a \u06a9\u0647 \u06cc\u06a9 \u06a9\u0627\u0628\u0644 \u0628\u0647 \u0637\u0648\u0631 \u062e\u0648\u062f\u06a9\u0627\u0631 \u0633\u0631\u06cc\u0639\u200c\u062a\u0631 \u062e\u0648\u0627\u0647\u062f \u0628\u0648\u062f. \u0637\u0648\u0644 \u0645\u0648\u062c \u0627\u0631\u0633\u0627\u0644\u200c\u06a9\u0646\u0646\u062f\u0647\u060c \u0646\u0648\u0639 \u06af\u06cc\u0631\u0646\u062f\u0647-\u067e\u0631\u062f\u0647\u0646\u062f\u0647\u060c \u0645\u0634\u062e\u0635\u0627\u062a \u0641\u06cc\u0628\u0631\u060c \u0627\u062a\u0635\u0627\u0644 \u0648 \u062f\u0633\u062a\u0631\u0633\u06cc \u0645\u0648\u0631\u062f \u0646\u06cc\u0627\u0632 \u0647\u0645\u0647 \u0628\u0627\u06cc\u062f \u0628\u0627 \u0647\u0645 \u0645\u0646\u0637\u0628\u0642 \u0628\u0627\u0634\u0646\u062f. ITU-T G.652 \u0648\u06cc\u0698\u06af\u06cc\u200c\u0647\u0627\u06cc \u0641\u06cc\u0628\u0631 \u0648 \u06a9\u0627\u0628\u0644 \u0646\u0648\u0631\u06cc \u062a\u06a9\u200c\u0645\u062f \u0631\u0627 \u062a\u0648\u0635\u06cc\u0641 \u0645\u06cc\u200c\u06a9\u0646\u062f\u060c \u062f\u0631 \u062d\u0627\u0644\u06cc \u06a9\u0647 ITU-T G.651.1 \u0641\u06cc\u0628\u0631 \u0648 \u06a9\u0627\u0628\u0644 \u0686\u0646\u062f\u0645\u062f\u06cc \u0634\u0627\u062e\u0635 \u062a\u062f\u0631\u06cc\u062c\u06cc 50\/125 \u00b5m \u0631\u0627 \u0628\u0631\u0627\u06cc \u0634\u0628\u06a9\u0647\u200c\u0647\u0627\u06cc \u062f\u0633\u062a\u0631\u0633\u06cc \u0646\u0648\u0631\u06cc \u067e\u0648\u0634\u0634 \u0645\u06cc\u200c\u062f\u0647\u062f.<\/p>\n<p>\u0627\u0632 \u0642\u0637\u0631 \u0628\u06cc\u0631\u0648\u0646\u06cc \u06a9\u0627\u0628\u0644 \u06cc\u0627 \u0634\u06a9\u0644 \u0622\u0634\u0646\u0627 \u067e\u0644\u0627\u06af \u0628\u0631\u0627\u06cc \u0627\u0633\u062a\u0646\u062a\u0627\u062c \u0633\u0627\u0632\u06af\u0627\u0631\u06cc \u06a9\u0646\u06a9\u062a\u0648\u0631 \u0627\u0633\u062a\u0641\u0627\u062f\u0647 \u0646\u06a9\u0646\u06cc\u062f. \u0646\u0648\u0639 \u0641\u06cc\u0628\u0631\u060c \u0631\u0627\u0628\u0637 \u06a9\u0646\u06a9\u062a\u0648\u0631\u060c \u0646\u0648\u0639 \u067e\u0644\u06cc\u0634 (\u062f\u0631 \u0645\u0648\u0627\u0631\u062f \u0645\u0631\u062a\u0628\u0637)\u060c \u0637\u0648\u0644 \u0645\u0648\u062c \u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u0648 \u0641\u0627\u0635\u0644\u0647 \u0645\u062c\u0627\u0632 \u0627\u062a\u0635\u0627\u0644 \u0631\u0627 \u0627\u0632 \u0645\u0633\u062a\u0646\u062f\u0627\u062a \u0648\u0627\u0642\u0639\u06cc \u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u062b\u0628\u062a \u06a9\u0646\u06cc\u062f. \u062f\u0631 \u0635\u0648\u0631\u062a \u0648\u062c\u0648\u062f \u0632\u06cc\u0631\u0633\u0627\u062e\u062a \u0645\u0648\u062c\u0648\u062f\u060c \u0642\u0628\u0644 \u0627\u0632 \u062e\u0631\u06cc\u062f \u0627\u067e\u062a\u06cc\u06a9\u200c\u0647\u0627\u060c \u0641\u06cc\u0628\u0631 \u0646\u0635\u0628\u200c\u0634\u062f\u0647 \u0631\u0627 \u0628\u0627 \u0627\u0633\u062a\u0641\u0627\u062f\u0647 \u0627\u0632 \u0633\u0648\u0627\u0628\u0642 \u0648 \u062a\u0623\u06cc\u06cc\u062f \u0645\u0646\u0627\u0633\u0628 \u062f\u0631 \u0645\u06cc\u062f\u0627\u0646 \u0634\u0646\u0627\u0633\u0627\u06cc\u06cc \u06a9\u0646\u06cc\u062f. <a href=\"https:\/\/microductconnector.com\/blog\/the-future-trends-of-optical-communication\/\">\u0631\u0648\u0646\u062f\u0647\u0627\u06cc \u0622\u06cc\u0646\u062f\u0647 \u062f\u0631 \u0627\u0631\u062a\u0628\u0627\u0637\u0627\u062a \u0646\u0648\u0631\u06cc<\/a> \u0627\u0645\u0631\u0648\u0632\u0647\u060c \u0627\u06cc\u0646 \u0631\u0648\u0627\u0628\u0637 \u0648 \u06cc\u06a9 \u0645\u0633\u06cc\u0631 \u0628\u0647\u200c\u0631\u0648\u0632\u0631\u0633\u0627\u0646\u06cc \u0648\u0627\u0642\u0639\u200c\u0628\u06cc\u0646\u0627\u0646\u0647 \u0646\u0633\u0628\u062a \u0628\u0647 \u0644\u06cc\u0633\u062a \u0645\u0648\u0627\u062f (BOM) \u0627\u0647\u0645\u06cc\u062a \u0628\u06cc\u0634\u062a\u0631\u06cc \u062f\u0627\u0631\u0646\u062f.<\/p>\n<table>\n<caption>\u0645\u062f \u0648\u0627\u062d\u062f \u0648 \u0686\u0646\u062f\u06af\u0627\u0646\u0647: \u062a\u0641\u0627\u0648\u062a\u200c\u0647\u0627\u06cc \u0637\u0631\u0627\u062d\u06cc \u0628\u0631\u0627\u06cc \u062a\u0623\u06cc\u06cc\u062f<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">\u0646\u0642\u0637\u0647 \u062a\u0635\u0645\u06cc\u0645\u200c\u06af\u06cc\u0631\u06cc<\/th>\n<th scope=\"col\">\u062d\u0627\u0644\u062a \u062a\u06a9\u200c\u0645\u062f<\/th>\n<th scope=\"col\">\u0686\u0646\u062f\u06af\u0627\u0646\u0647<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">\u0627\u0646\u062a\u0634\u0627\u0631 \u0646\u0648\u0631<\/th>\n<td>\u06cc\u06a9 \u0631\u0648\u0634 \u0627\u0635\u0644\u06cc\u061b G.652 \u06cc\u06a9 \u0645\u0631\u062c\u0639 \u0641\u06cc\u0628\u0631\u06cc \u0645\u062e\u0627\u0628\u0631\u0627\u062a\u06cc \u0645\u0631\u062a\u0628\u0637 \u0627\u0633\u062a.<\/td>\n<td>\u0686\u0646\u062f\u06cc\u0646 \u062d\u0627\u0644\u062a\u061b G.651.1 \u0628\u0631\u0627\u06cc \u0641\u06cc\u0628\u0631 \u0628\u0627 \u0634\u0627\u062e\u0635 \u062a\u062f\u0631\u06cc\u062c\u06cc 50\/125 \u00b5m \u062f\u0631 \u0634\u0628\u06a9\u0647\u200c\u0647\u0627\u06cc \u062f\u0633\u062a\u0631\u0633\u06cc \u0646\u0648\u0631\u06cc \u0627\u0633\u062a\u0641\u0627\u062f\u0647 \u0645\u06cc\u200c\u0634\u0648\u062f.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u062f\u0633\u062a\u0631\u0633\u06cc \u0648 \u062a\u062c\u0647\u06cc\u0632\u0627\u062a<\/th>\n<td>\u0628\u06cc\u0627\u06cc\u06cc\u062f \u0627\u067e\u062a\u06cc\u06a9\u200c\u0647\u0627\u06cc \u0627\u0646\u062a\u062e\u0627\u0628 \u0634\u062f\u0647\u060c \u0637\u0648\u0644 \u0645\u0648\u062c \u0648 \u06a9\u0644 \u0628\u0648\u062f\u062c\u0647 \u062a\u0644\u0641\u0627\u062a \u0631\u0627 \u0628\u0631\u0627\u06cc \u0645\u0633\u06cc\u0631 \u0648\u0627\u0642\u0639\u06cc \u0628\u0631\u0631\u0633\u06cc \u06a9\u0646\u06cc\u0645.<\/td>\n<td>\u062f\u0631\u062c\u0647\u200c\u06cc \u0645\u062e\u0635\u0648\u0635 \u0686\u0646\u062f\u06af\u0627\u0646\u0647\u060c \u0627\u067e\u062a\u06cc\u06a9 \u0648 \u062f\u0633\u062a\u0631\u0633\u06cc \u0645\u0646\u062a\u0634\u0631\u0634\u062f\u0647 \u0631\u0627 \u0628\u0631\u0631\u0633\u06cc \u06a9\u0646\u06cc\u062f\u061b \u067e\u0631\u0627\u06a9\u0646\u062f\u06af\u06cc \u0645\u0648\u062f\u0627\u0644 \u0645\u06cc\u200c\u062a\u0648\u0627\u0646\u062f \u0645\u062d\u062f\u0648\u062f\u06cc\u062a\u06cc \u0628\u0631\u0627\u06cc \u0627\u062a\u0635\u0627\u0644 \u0627\u06cc\u062c\u0627\u062f \u06a9\u0646\u062f.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">\u0627\u0646\u0637\u0628\u0627\u0642 \u067e\u0627\u06cc\u0647 \u0646\u0635\u0628 \u0634\u062f\u0647<\/th>\n<td>\u062b\u0628\u062a\u200c\u0647\u0627\u06cc \u0641\u06cc\u0628\u0631\u060c \u0648\u0636\u0639\u06cc\u062a \u06a9\u0646\u06a9\u062a\u0648\u0631\u0647\u0627 \u0648 \u0633\u0627\u0632\u06af\u0627\u0631\u06cc \u0641\u0631\u0633\u062a\u0646\u062f\u0647-\u06af\u06cc\u0631\u0646\u062f\u0647 \u0631\u0627 \u0628\u0631\u0631\u0633\u06cc \u06a9\u0646\u06cc\u062f.<\/td>\n<td>Verify fiber grade and continuity; the word \u201cmultimode\u201d alone is insufficient.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Cost tendency<\/th>\n<td>Compare transceivers, cable, termination and testing as a system, not just fiber price.<\/td>\n<td>Compare the same complete scope; equipment and reach can reverse a simple material-price assumption.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Keep cable handling limits separate from fiber type<\/h2>\n<p>A fiber designation describes optical characteristics; the finished cable adds coatings, buffers, strength members and an outer construction that also affect handling. Do not infer a permitted cable <strong class=\"blog-core-keyword\">\u0634\u0639\u0627\u0639 \u0627\u0646\u062d\u0646\u0627\u0621<\/strong> or installation force from the glass type alone. Obtain the manufacturer&#8217;s limits for installation under load and for the final installed condition, including any temperature or handling restrictions.<\/p>\n<p>This distinction matters when bend-insensitive fiber is proposed for a compact route. Improved bending-loss behavior is not permission to crease a cable, crush it under a fixing or force it around an undocumented corner. The installed cable and termination instructions still govern. A passing optical test at one point in time does not authorize an installation that violates those mechanical instructions.<\/p>\n<p>For a ducted route, compare the cable diameter and stiffness with the bore, bends and access plan. The <a href=\"https:\/\/microductconnector.com\/blog\/air-blown-or-traditional-cabling\/\">air-blown versus conventional cabling comparison<\/a> explains why the installation method changes pathway requirements without changing the need for optical acceptance. Keep the selected cable unit, duct size, joint arrangement and method in the same route record.<\/p>\n<p>When changing a cable or fiber unit, repeat the compatibility review rather than assuming that the same strand count implies the same installation behavior. Review the <a href=\"https:\/\/microductconnector.com\/hdpe-microducts\/\">\u062f\u0633\u062a\u0647\u200c\u0628\u0646\u062f\u06cc \u0645\u06cc\u06a9\u0631\u0648\u06a9\u0627\u0646\u0627\u0644 HDPE<\/a> alongside actual dimensions and the cable maker&#8217;s instructions. Record any approved substitution and whether it changes the optical budget, handling method or termination process before work begins.<\/p>\n<h2>Calculate the Link-Loss Budget and Test the Installed Fiber<\/h2>\n<p>Begin with the receiver sensitivity and transmitter output specified for the chosen optics, then account for fiber attenuation over the route length, planned splices, connector pairs and a project-defined reserve. For an illustrative estimate, planned loss = fiber attenuation + splice losses + connector losses + engineering margin; the component values must come from the selected products and project acceptance criteria. There is no universal acceptable loss figure for every link.<\/p>\n<p>After installation, use a calibrated optical loss test set at the wavelengths and reference method specified for the project to measure end-to-end <strong class=\"blog-core-keyword\">\u062a\u0644\u0641\u0627\u062a \u0648\u0631\u0648\u062f\u06cc<\/strong>. An optical time-domain reflectometer (OTDR) can help locate events and characterize the route, but its trace is not a substitute for the agreed end-to-end loss measurement. FOA&#8217;s testing references explain the different purposes of these methods. Keep test records tied to the fiber identifiers and the as-built route so a later repair crew can distinguish a new fault from a pre-existing condition.<\/p>\n<p>The same budget should guide physical work. Keep the manufacturer&#8217;s minimum bend radius and pulling or blowing limits visible to the crew; protect open ends from dirt and moisture; inspect and clean mating optical connectors using the approved procedure before connection. For an air-blown system, verify the duct&#8217;s bore, continuity, bends and joints against the fiber unit and equipment instructions. A good fiber specification cannot compensate for a crushed duct or a contaminated interface.<\/p>\n<figure class=\"wp-block-image\" style=\"width:50%;max-width:600px;margin:1.5rem auto\"><img alt=\"Fiber optic duct fit check before installation\" decoding=\"async\" loading=\"lazy\" src=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/09\/1001-fiber-optic-duct-fit-check.webp\" style=\"width:100%;height:auto;display:block\"\/><\/figure>\n<h2>Use loss measurements and OTDR traces for different questions<\/h2>\n<p>An optical loss test set answers how much optical power is lost between defined endpoints under the selected test conditions. An OTDR provides a trace used to characterize events and locate features such as splices, reflections or suspected damage. <a href=\"https:\/\/www.flukenetworks.com\/expertise\/learn-about\/otdr\" rel=\"nofollow noopener\" target=\"_blank\">Fluke Networks&#8217; OTDR guidance<\/a> explains their different roles. An OTDR result should not silently replace an end-to-end insertion-loss measurement required by the contract.<\/p>\n<p>Make the test boundary explicit: installed cable plant, a defined link including patching, or another stated configuration. Record wavelengths, reference method, fiber identifiers, test direction where required and the acceptance limit. For an OTDR, the setup must suit the events that need to be resolved; launch and receive fibers may be needed to assess end connections. The project procedure should define that setup rather than borrowing an instrument&#8217;s default settings.<\/p>\n<p>The <a href=\"https:\/\/microductconnector.com\/blog\/mastering-internet-connectors-plugs-for-optimal-network-performance\/\">network connector and plug guide<\/a> covers the mating interface that precedes these measurements. Inspect, clean when necessary and inspect again before connecting. If a result changes after cleaning or rerouting a bend, retain the initial and final records and state the correction. This is more useful for maintenance than a final pass result with no route or port identity.<\/p>\n<h2>Compare the Complete Installed Route Before Buying<\/h2>\n<p>Fiber optic technology advantages often include high capacity, long-reach options and immunity of the glass signal path to electromagnetic interference. These are system-level possibilities, not guarantees for every route or a certification of the cable. Procurement should compare the complete installed link: compatible optics, fiber and cable, pathway, fittings, termination, tests, documentation and the cost of gaining access for future changes.<\/p>\n<p>A low cable quote can become expensive if interfaces have to be reworked or the route must be reopened. Conversely, spare pathway capacity has value only when it is recorded, accessible and kept suitable for later use. Model the present installation and a plausible expansion scenario over the same planning period; label future demand and crew costs as assumptions. Do not claim a payback period until those inputs are known.<\/p>\n<table>\n<caption>Checks that turn an optical design into a purchase specification<\/caption>\n<thead>\n<tr>\n<th scope=\"col\">\u0634\u0631\u0627\u06cc\u0637 \u067e\u0631\u0648\u0698\u0647<\/th>\n<th scope=\"col\">\u0645\u062f\u0627\u0631\u06a9 \u0644\u0627\u0632\u0645 \u0628\u0631\u0627\u06cc \u062f\u0631\u062e\u0648\u0627\u0633\u062a<\/th>\n<th scope=\"col\">\u062a\u0635\u0645\u06cc\u0645 \u06a9\u0647 \u0622\u0646 \u0631\u0627 \u062d\u0645\u0627\u06cc\u062a \u0645\u06cc\u200c\u06a9\u0646\u062f<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<th scope=\"row\">Known equipment at both ends<\/th>\n<td>Optics data, wavelength, supported fiber type and allowable loss.<\/td>\n<td>Choose compatible fiber and calculate the route-specific budget.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Existing fiber route<\/th>\n<td>As-built records, fiber identification, connector condition and field test results.<\/td>\n<td>Decide whether reuse is feasible before ordering replacement components.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">New microduct route<\/th>\n<td>Duct and fiber-unit dimensions, bend plan, joint details and installation instructions.<\/td>\n<td>Check physical fit and installation method before selecting fittings.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Phased expansion<\/th>\n<td>Demand scenarios, spare usable pathway, access points and future mobilization estimate.<\/td>\n<td>Compare whole-life options without assuming spare capacity is free.<\/td>\n<\/tr>\n<tr>\n<th scope=\"row\">Acceptance and maintenance<\/th>\n<td>Loss-test method, wavelengths, limits, fiber IDs and as-built deliverables.<\/td>\n<td>Make acceptance repeatable and future fault isolation faster.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Match Each Fiber Standard to Its Stated Scope<\/h2>\n<p>ITU-T G.652 defines characteristics for a single-mode optical fiber and cable; ITU-T G.651.1 defines characteristics for 50\/125 \u00b5m graded-index multimode optical fiber and cable for optical access networks. They help specify fiber, not certify a completed link, a microduct fitting or a contractor&#8217;s workmanship. FOA technical references are educational guidance on fiber, installation and testing, not a product approval. Contracts should name the exact standard edition, fiber variant, equipment requirements and field acceptance method that apply.<\/p>\n<p>Compliance claims must also match the destination market, intended application and evidence supplied. Ask for the selected product&#8217;s datasheet and applicable test documentation instead of accepting a blanket \u201cstandards compliant\u201d label. Unsupported claims can result in a rejected submittal, procurement delay or costly replacement even when the components physically fit.<\/p>\n<h2>Define the interfaces before requesting quotes<\/h2>\n<ol>\n<li>State the service, route length, equipment at both ends and expected growth; get the transceiver makers&#8217; supported fiber and link limits.<\/li>\n<li>Identify the fiber type and cable construction, then calculate the loss budget from actual route and component data.<\/li>\n<li>Draw the pathway, bends, access points, joints and terminations; confirm duct-to-cable or duct-to-fiber-unit fit from both manufacturers.<\/li>\n<li>Set an installation method and an acceptance plan with wavelengths, test method, thresholds and deliverable records before work starts.<\/li>\n<li>Compare complete installed and future-access costs, including any spare pathway, rather than choosing on cable unit price.<\/li>\n<\/ol>\n<p>Microduct Connector can help buyers review the fitting and pathway side of a fiber route against the documented duct dimensions and application. For access-network context, see <a href=\"https:\/\/microductconnector.com\/blog\/what-is-ftth-the-role-of-microduct-connectors-in-ftth\/\">fiber-to-the-home microduct design<\/a>. Optical fiber and microduct fittings perform different jobs, so confirm each interface independently.<\/p>\n<h2>\u0633\u0648\u0627\u0644\u0627\u062a \u0645\u062a\u062f\u0627\u0648\u0644<\/h2>\n<h3>How does fiber optic communication work?<\/h3>\n<p>A transmitter encodes data into light, the optical fiber guides the signal, and a receiver converts it back to electrical data. Core and cladding refractive indices help guide light through total internal reflection. The usable link still depends on attenuation, connections, bends and the chosen optics.<\/p>\n<h3>\u062a\u0641\u0627\u0648\u062a \u0628\u06cc\u0646 \u0641\u06cc\u0628\u0631 \u062a\u06a9\u200c\u0645\u062f \u0648 \u0686\u0646\u062f\u200c\u0645\u062f \u0686\u06cc\u0633\u062a\u061f<\/h3>\n<p>Single-mode supports one principal propagation mode; multimode supports multiple modes. ITU-T G.652 and G.651.1 address different fiber types, but the correct choice also depends on transceivers, wavelength, reach and installed infrastructure. Do not mix them based on connector appearance alone.<\/p>\n<h3>Does optical fiber lose signal over distance?<\/h3>\n<p>Yes. The glass has attenuation, and splices, connectors and bends can add loss. Calculate the budget for the specific link, then measure the installed link using the project&#8217;s stated wavelengths and reference method.<\/p>\n<h3>Is optical fiber immune to every type of interference?<\/h3>\n<p>The optical signal in glass is not carried as an electrical current, so electromagnetic interference does not affect it in the way it affects a metallic signal path. That does not make the whole system immune to power, equipment, grounding or physical-installation problems. Assess those separately.<\/p>\n<h3>Can single-mode fiber be installed in any microduct?<\/h3>\n<p>No. Fiber type does not establish cable outer diameter, duct clearance or installation suitability. Check the actual cable or fiber unit, duct bore, route geometry, fittings and installation-equipment instructions together.<\/p>\n<h3>Which test confirms a newly installed fiber link?<\/h3>\n<p>An optical loss test set measures end-to-end insertion loss against the agreed budget at specified wavelengths. An OTDR helps characterize and locate events, but it answers a different question. Record the method, limits and results against each fiber identifier.<\/p>\n<h3>Does bend-insensitive fiber allow a cable to be bent without limits?<\/h3>\n<p>No. Optical bending performance and the finished cable&#8217;s mechanical limits are separate. Follow the cable manufacturer&#8217;s installed and loaded bend-radius requirements, handling limits and termination instructions. Do not use a fiber designation to justify a kink or a crushed fixing point.<\/p>\n<h3>What should be recorded when a failed optical link passes after cleaning?<\/h3>\n<p>Retain the fiber and port identifiers, initial result, inspection or cleaning action, reference method and final test result. Use the same agreed acceptance boundary and wavelengths so the correction can be understood and the records remain useful for later maintenance.<\/p>\n<h2>\u0645\u0631\u0627\u062c\u0639<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.itu.int\/rec\/T-REC-G.652\/en\" rel=\"nofollow noopener\" target=\"_blank\">ITU-T G.652, Characteristics of a single-mode optical fibre and cable<\/a>.<\/li>\n<li><a href=\"https:\/\/www.itu.int\/rec\/T-REC-G.651.1\/en\" rel=\"nofollow noopener\" target=\"_blank\">ITU-T G.651.1, Characteristics of a 50\/125 \u00b5m multimode graded index optical fibre cable for the optical access network<\/a>.<\/li>\n<li><a href=\"https:\/\/www.thefoa.org\/tech\/ref\/\" rel=\"nofollow noopener\" target=\"_blank\">Fiber Optic Association, Online Reference Guide to Fiber Optics<\/a>.<\/li>\n<li><a href=\"https:\/\/www.flukenetworks.com\/expertise\/learn-about\/otdr\" rel=\"nofollow noopener\" target=\"_blank\">Fluke Networks: OTDR Testing and Optical Link Characterization<\/a><\/li>\n<\/ul>\n<h2>\u062e\u0644\u0627\u0635\u0647<\/h2>\n<p>Fiber carries information as light, but the usable link depends on equipment compatibility, attenuation, connections and installation quality. Select the fiber and cable against the actual optics and route, preserve the cable&#8217;s handling limits and establish a project-specific loss budget. Use end-to-end loss testing and OTDR characterization for their respective purposes, with identifiable records. Keep the optical signal path and the protective duct pathway coordinated without treating one component&#8217;s specification as proof of the whole system.<\/p>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>\u0628\u0641\u0647\u0645\u0646\u062f \u06a9\u0647 \u0641\u06cc\u0628\u0631 \u0646\u0648\u0631\u06cc \u0686\u06af\u0648\u0646\u0647 \u062f\u0627\u062f\u0647\u200c\u0647\u0627 \u0631\u0627 \u0627\u0646\u062a\u0642\u0627\u0644 \u0645\u06cc\u200c\u062f\u0647\u062f\u060c \u0686\u0647 \u0632\u0645\u0627\u0646\u06cc \u0628\u0627\u06cc\u062f \u0627\u0632 \u0641\u06cc\u0628\u0631 \u062a\u06a9\u200c\u0645\u062f (single-mode) \u06cc\u0627 \u0686\u0646\u062f\u06cc\u0646\u200c\u0645\u062f (multimode) \u0627\u0633\u062a\u0641\u0627\u062f\u0647 \u06a9\u0646\u06cc\u062f\u060c \u0648 \u062f\u0631 \u06cc\u06a9 \u0645\u0633\u06cc\u0631 \u0641\u06cc\u0628\u0631\u06cc \u06a9\u062f\u0627\u0645 \u0645\u0639\u0627\u06cc\u0646\u0627\u062a \u0645\u0631\u0628\u0648\u0637 \u0628\u0647 \u062a\u0644\u0641\u0627\u062a\u060c \u0646\u0635\u0628 \u0648 \u0622\u0632\u0645\u0627\u06cc\u0634 \u0627\u0647\u0645\u06cc\u062a \u062f\u0627\u0631\u0646\u062f.<\/p>","protected":false},"author":2,"featured_media":5279,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[21],"tags":[],"class_list":["post-4080","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-insights"],"_links":{"self":[{"href":"https:\/\/microductconnector.com\/fa\/wp-json\/wp\/v2\/posts\/4080","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/microductconnector.com\/fa\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/microductconnector.com\/fa\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/fa\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/fa\/wp-json\/wp\/v2\/comments?post=4080"}],"version-history":[{"count":7,"href":"https:\/\/microductconnector.com\/fa\/wp-json\/wp\/v2\/posts\/4080\/revisions"}],"predecessor-version":[{"id":4906,"href":"https:\/\/microductconnector.com\/fa\/wp-json\/wp\/v2\/posts\/4080\/revisions\/4906"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/fa\/wp-json\/wp\/v2\/media\/5279"}],"wp:attachment":[{"href":"https:\/\/microductconnector.com\/fa\/wp-json\/wp\/v2\/media?parent=4080"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/microductconnector.com\/fa\/wp-json\/wp\/v2\/categories?post=4080"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/microductconnector.com\/fa\/wp-json\/wp\/v2\/tags?post=4080"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}