{"id":5453,"date":"2026-11-13T00:00:00","date_gmt":"2026-11-13T00:00:00","guid":{"rendered":"https:\/\/microductconnector.com\/?p=5453"},"modified":"2026-11-10T04:09:52","modified_gmt":"2026-11-10T04:09:52","slug":"microduct-fiber-cable-matching","status":"publish","type":"post","link":"https:\/\/microductconnector.com\/es\/blog\/microduct-fiber-cable-matching\/","title":{"rendered":"Fibra en microconductos: C\u00f3mo hacer coincidir el cable y el conducto"},"content":{"rendered":"<article>\n<p>En un despliegue hipot\u00e9tico y escalonado de fibra \u00f3ptica en M\u00e1nchester, un contratista solicita un cable con mayor n\u00famero de fibras para una ruta existente de microconductos. El cable cabe en el extremo abierto, pero esa comprobaci\u00f3n sencilla no indica si podr\u00e1 recorrer toda la ruta. Su di\u00e1metro, rigidez, cubierta, uniones y los equipos de instalaci\u00f3n son factores determinantes. Elegir el conducto y el cable de forma independiente puede convertir una ampliaci\u00f3n de capacidad prevista en una instalaci\u00f3n compleja.<\/p>\n<p><strong>Fibra de microducto<\/strong> Por lo general, significa un peque\u00f1o cable \u00f3ptico o una unidad de fibra instalada en un conducto peque\u00f1o dedicado. Especifique el cable y el microconducto como un par compatible, luego verifique los conectores y los l\u00edmites de instalaci\u00f3n. Una etiqueta como 12\/10 mm normalmente describe los di\u00e1metros exterior e interior del conducto, no un cable permitido de 12 mm. Confirme la notaci\u00f3n del proveedor y las tolerancias dimensionales.<\/p>\n<h2>Comprenda qu\u00e9 se transporta dentro del microconducto.<\/h2>\n<p>El microconducto es la v\u00eda de protecci\u00f3n. El cable \u00f3ptico o la unidad de fibra es el medio de transmisi\u00f3n que se instala en su interior. El conducto circundante no determina el tipo de fibra, la velocidad de la red ni la distancia \u00f3ptica permitida. Estos aspectos dependen de la fibra seleccionada, los transceptores, los conectores, las uniones por empalme y el dise\u00f1o completo del enlace.<\/p>\n<p>La Asociaci\u00f3n de Fibra \u00d3ptica diferencia las unidades de fibra soplada por aire de los cables soplados. Las peque\u00f1as unidades de fibra con recubrimiento especial y los microcables con cubierta no son intercambiables simplemente porque ambos pueden instalarse mediante soplado con aire. Su equipo de instalaci\u00f3n, los requisitos de manipulaci\u00f3n y las combinaciones de tubos compatibles pueden variar. Indique qu\u00e9 sistema se est\u00e1 especificando antes de solicitar un presupuesto para conductos.<\/p>\n<p>Un conducto convencional para cables puede acomodar un cable de mayor tama\u00f1o y un m\u00e9todo de instalaci\u00f3n diferente. Los sistemas de microconductos dividen la capacidad en canales individuales m\u00e1s peque\u00f1os, lo que permite a\u00f1adir cables de forma gradual. El beneficio radica en una ruta planificada con canales de reserva, accesos adecuados y un cable que el equipo seleccionado pueda instalar. El di\u00e1metro reducido por s\u00ed solo no garantiza ese resultado.<\/p>\n<div style=\"overflow-x:auto;\">\n<table style=\"width:100%;border-collapse:collapse;margin:20px 0;font-size:15px;line-height:1.5;\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;background:#eaf0f5;\">Elemento del sistema<\/th>\n<th style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;background:#eaf0f5;\">Funci\u00f3n principal<\/th>\n<th style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;background:#eaf0f5;\">Comprobaci\u00f3n de selecci\u00f3n<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Microcable o unidad de fibra<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Transporta se\u00f1ales \u00f3pticas<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Especificaci\u00f3n de la fibra, di\u00e1metro exterior, rigidez, cubierta y l\u00edmites de instalaci\u00f3n<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Microducto<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Proporciona una ruta personalizada<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Di\u00e1metro \u00fatil, construcci\u00f3n de la pared y entorno de la ruta<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Conector de conducto<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Contin\u00faa la trayectoria del conducto en una uni\u00f3n<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Ajuste OD, holgura de paso y sello requerido<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Equipo de soplado<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Instala el cable o la unidad compatible.<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Rango de cables, adaptadores para conductos e instrucciones de funcionamiento<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Terminaci\u00f3n \u00f3ptica<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Une o conecta fibras<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Compatibilidad de la fibra, limpieza y rendimiento \u00f3ptico medido<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<h2>Ajuste el di\u00e1metro del microcable al di\u00e1metro \u00fatil del microconducto.<\/h2>\n<p>Comience con el di\u00e1metro exterior m\u00e1ximo especificado del cable y el di\u00e1metro interior \u00fatil m\u00ednimo del microducto. Obtenga esos valores de los documentos actuales del producto. Un orificio nominal de 10 mm no es garant\u00eda de que cada punto de la ruta instalada ofrezca ese espacio libre. Las tolerancias de pared, la ovalidad, la contaminaci\u00f3n y la geometr\u00eda del acoplador pueden reducir el recorrido disponible.<\/p>\n<p>Un cable ilustrativo de 6 mm en un orificio circular de 10 mm tiene una relaci\u00f3n de di\u00e1metros del 60 por ciento y una relaci\u00f3n de \u00e1reas transversales del 36 por ciento. Estos c\u00e1lculos describen aspectos diferentes: la relaci\u00f3n de \u00e1reas es el cuadrado de la relaci\u00f3n de di\u00e1metros. Ninguno de los dos n\u00fameros, por s\u00ed solo, demuestra que el cable est\u00e9 aprobado para su insuflaci\u00f3n en ese conducto ni predice la distancia de instalaci\u00f3n.<\/p>\n<figure style=\"width:50%;max-width:600px;margin:24px auto;text-align:center;\"><img alt=\"Conceptual comparison of cable clearance in two microduct bores, not an approved sizing ratio\" decoding=\"async\" height=\"800\" loading=\"lazy\" src=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/11\/microduct-fiber-cable-matching-detail.webp\" style=\"display:block;width:100%;height:auto;border-radius:6px;\" width=\"600\"\/><figcaption style=\"font-size:14px;line-height:1.5;color:#52616d;margin-top:8px;\">Comparaci\u00f3n conceptual de la holgura del cable en dos conductos para microductos; no se trata de una relaci\u00f3n de dimensionamiento aprobada.<\/figcaption><\/figure>\n<p>Utilice la combinaci\u00f3n recomendada por el proveedor del cable o del sistema de soplado. Un cable demasiado grande puede dejar espacio insuficiente para el proceso de instalaci\u00f3n previsto. Un cable m\u00e1s peque\u00f1o tampoco es autom\u00e1ticamente mejor, ya que la rigidez, la guiabilidad y el comportamiento durante el manejo tambi\u00e9n son importantes. Evite convertir una regla gen\u00e9rica sobre el llenado del conducto en una recomendaci\u00f3n universal para microductos.<\/p>\n<p>Incluya cada cambio a lo largo del recorrido. Un reductor, una curva, una junta desplazada o una transici\u00f3n a otra familia de conductos pueden convertirse en el punto limitante. El <a href=\"https:\/\/microductconnector.com\/blog\/optical-microduct-connector-sizing\/\">Gu\u00eda de dimensionamiento de conectores para microconductos<\/a> explica por qu\u00e9 la selecci\u00f3n del conector requiere tanto comprobaciones de ajuste en el conducto como de paso del cable. El cable debe atravesar la uni\u00f3n completa, no solo una secci\u00f3n sin conectar del tubo.<\/p>\n<h2>Elija el equipo de soplado para el cable y la ruta<\/h2>\n<p><strong>Microconducto de fibra \u00f3ptica<\/strong> Las instalaciones suelen utilizar aire comprimido junto con alimentaci\u00f3n mec\u00e1nica de cables, seg\u00fan el sistema. En la industria, los t\u00e9rminos soplado y inyecci\u00f3n se emplean de manera similar, mientras que algunos sistemas de unidades de fibra cuentan con equipos y procedimientos espec\u00edficos. Utilice la descripci\u00f3n del proceso proporcionada por el fabricante del equipo en lugar de asumir que todas las instalaciones con asistencia de aire funcionan de la misma manera.<\/p>\n<p>Confirme el di\u00e1metro y la construcci\u00f3n del cable admitidos por la m\u00e1quina, los adaptadores y sellos de conducto adecuados, as\u00ed como las fuerzas de instalaci\u00f3n permitidas para el cable. Verifique tambi\u00e9n la calidad del suministro de aire especificada y la capacidad del equipo. El hecho de que una m\u00e1quina pueda aceptar mec\u00e1nicamente el cable no constituye prueba suficiente de que pueda instalarlo a lo largo de la distancia y seg\u00fan la geometr\u00eda del recorrido propuestos.<\/p>\n<p>Las curvas del trazado, los cambios de elevaci\u00f3n, la fricci\u00f3n, las p\u00e9rdidas y la rigidez del cable influyen en la instalaci\u00f3n. No existe una garant\u00eda universal v\u00e1lida que asegure que un di\u00e1metro determinado de microconducto permita alcanzar una distancia espec\u00edfica. Solicite una evaluaci\u00f3n adaptada al trazado y un plan pr\u00e1ctico para el acceso y la manipulaci\u00f3n intermedia. No confunda la mejor distancia demostrada por el proveedor con un compromiso aplicable a otro emplazamiento.<\/p>\n<p>FOA destaca que los cables \u00f3pticos tienen tensiones m\u00e1ximas de tracci\u00f3n y radios m\u00ednimos de curvatura. La instalaci\u00f3n asistida por aire no elimina los l\u00edmites mec\u00e1nicos en el equipo de alimentaci\u00f3n, el carrete o la c\u00e1mara. Planifique la salida del carrete y las transiciones para que el cable entre sin problemas, con el soporte adecuado y sin cambios bruscos de direcci\u00f3n inmediatamente antes de la m\u00e1quina.<\/p>\n<h2>Verifique la continuidad del conducto y las uniones antes de instalar el cable.<\/h2>\n<p>Debe identificarse una ruta de microductos que sea continua, limpia y est\u00e9 preparada seg\u00fan las instrucciones del sistema seleccionado antes de la llegada del cable. Confirme los puntos de terminaci\u00f3n correctos y registre cualquier cambio en el tama\u00f1o o tipo de ducto. Realice la comprobaci\u00f3n completa de la ruta y los controles de uni\u00f3n requeridos con el equipo adecuado y las precauciones especificadas.<\/p>\n<p>Un resultado relacionado con la presi\u00f3n y un resultado de holgura no son equivalentes. Una tuber\u00eda puede mantener la presi\u00f3n aun cuando contenga una obstrucci\u00f3n, o bien puede tener una holgura adecuada pero perder aire debido a una uni\u00f3n mal preparada. Utilice las verificaciones requeridas por separado y registre las condiciones, la duraci\u00f3n y los criterios de aceptaci\u00f3n, en lugar de escribir \u00fanicamente \u201cprobado\u201d en un formulario de entrega.<\/p>\n<p>El <a href=\"https:\/\/microductconnector.com\/blog\/clear-microduct-connector-testing\/\">clear microduct connector testing guide<\/a> provides a focused way to review a suspect connection. Transparency can help an installer observe tube position, but appearance cannot replace the applicable installation and test procedure. Do not increase pressure beyond the documented system limit to force a cable past an unexplained obstruction.<\/p>\n<p>Keep supplier test data in context. The ANMASPC three-way 12\/10 mm bundle page lists a five-minute pressurization test for its individual ducts. That is a stated product test condition, not a universal operating instruction for the entire route. The complete installation also contains connectors, closures, equipment and a cable with their own limits.<\/p>\n<h2>Assign spare microduct channels before the first cable goes in<\/h2>\n<p><strong>Microduct bundles<\/strong> place several channels within one supplied assembly. Assign a route identifier and destination to each channel before installation. The identifier should remain consistent at branch points, chambers and cabinets, including where a channel changes color or passes through an intermediate connection.<\/p>\n<p>In a hypothetical three-channel rollout, one channel could serve the initial cable while two remain reserved for later phases. That allocation is a planning example, not a universal recommendation. The useful number of spares depends on the likely destinations, future cable sizes, access costs and the chance that a later route will need to branch elsewhere.<\/p>\n<figure style=\"width:50%;max-width:600px;margin:24px auto;text-align:center;\"><img alt=\"Conceptual three-channel route with one occupied channel and two reserved channels\" decoding=\"async\" height=\"800\" loading=\"lazy\" src=\"https:\/\/microductconnector.com\/wp-content\/uploads\/2026\/11\/microduct-fiber-cable-matching-diagram.webp\" style=\"display:block;width:100%;height:auto;border-radius:6px;\" width=\"600\"\/><figcaption style=\"font-size:14px;line-height:1.5;color:#52616d;margin-top:8px;\">Conceptual three-channel route with one occupied channel and two reserved channels.<\/figcaption><\/figure>\n<p>Cap unused channels with suitable components and retain their handover records. Before a later installation, check their condition again. Spare capacity can be lost through contamination, accidental damage or undocumented use, even when it appears on the original drawing. A route inventory should therefore record both design capacity and current occupancy.<\/p>\n<div style=\"overflow-x:auto;\">\n<table style=\"width:100%;border-collapse:collapse;margin:20px 0;font-size:15px;line-height:1.5;\">\n<thead>\n<tr>\n<th style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;background:#eaf0f5;\">Expansion decision<\/th>\n<th style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;background:#eaf0f5;\">Question to answer now<\/th>\n<th style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;background:#eaf0f5;\">Consequence if omitted<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Channel count<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">How many separate future routes are credible?<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Later work may require another pathway installation<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Channel destinations<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Where will each spare emerge?<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">An empty channel may not reach the future service point<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Access points<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Can equipment and cable reels reach the route?<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">A theoretically spare path may be impractical to use<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Size allowance<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Which future cable families are plausible?<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">A later cable may be incompatible with the reserved bore<\/td>\n<\/tr>\n<tr>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Records and caps<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Who maintains identity and condition?<\/td>\n<td style=\"border:1px solid #d5dee5;padding:10px;text-align:left;vertical-align:top;\">Expansion starts with investigation and repair<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Compare phased cable installation with installing additional fibers immediately. FOA notes that the economics of air-blown systems depend on initial tube provision and future use. Spare ducts may reduce later excavation, but they do not eliminate equipment, labor, testing or access costs. Include those costs in the expansion plan rather than presenting future cable additions as free.<\/p>\n<p>For procurement, send ANMASPC the required individual tube dimensions, bundle configuration, cable specification and installation environment. Request the associated drawing, dimensional tolerances and accessory recommendations. Where a building entry is involved, verify fire and penetration requirements separately from outdoor duct performance.<\/p>\n<h2>Preguntas frecuentes<\/h2>\n<h3>What is microduct fiber cable?<\/h3>\n<p>It is a small optical cable selected for installation inside a microduct. Some systems instead use specially coated fiber units. Confirm the specific cable or unit type because it affects the equipment, duct pairing and handling requirements.<\/p>\n<h3>How do microducts differ from conventional cable ducts?<\/h3>\n<p>Microducts provide smaller individual channels for matched micro cables or fiber units. Conventional ducts usually accommodate larger cable arrangements. Neither name alone establishes the permitted installation method, fire classification or cable capacity.<\/p>\n<h3>How do I match a micro cable to a microduct size?<\/h3>\n<p>Compare cable maximum OD with duct minimum usable bore, then confirm a supported pairing with the cable or system supplier. Review joints, bends and equipment as well. A cable fitting into the entrance does not demonstrate successful installation through the complete route.<\/p>\n<h3>How is fiber installed in a microduct?<\/h3>\n<p>It is commonly installed with an appropriate air-assisted system, though the approved method depends on the cable and duct design. Prepare and prove the route first. Follow the equipment and cable instructions rather than applying a generic pressure or force setting.<\/p>\n<h3>When is a fiber blowing machine needed for microduct installation?<\/h3>\n<p>Use one when the selected cable-and-duct system calls for machine-assisted blowing or jetting. The machine must suit the cable, duct and route. It is not a remedy for an unsuitable bore, an obstruction or an unapproved cable.<\/p>\n<h3>What is a microduct bundle used for?<\/h3>\n<p>A bundle supplies several identifiable channels in one assembly. It can support separate services and staged cable installation. Confirm both the individual channel dimensions and the overall bundle dimensions before ordering.<\/p>\n<h3>How can spare microducts support later network upgrades?<\/h3>\n<p>They provide reserved routes for later cable additions without reopening the whole pathway, where the original design allows that use. Keep them identified, capped and accessible. Verify their condition and compatibility again when the upgrade is planned.<\/p>\n<h2>Referencias<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.thefoa.org\/tech\/ref\/install\/AirBF.html\" rel=\"nofollow noopener\" target=\"_blank\">Asociaci\u00f3n de Fibra \u00d3ptica: Instalaci\u00f3n de fibra soplada por aire<\/a>.<\/li>\n<li><a href=\"https:\/\/www.thefoa.org\/tech\/ref\/install\/installcbl.html\" rel=\"nofollow noopener\" target=\"_blank\">Asociaci\u00f3n de Fibra \u00d3ptica: Instalaci\u00f3n de Cable de Fibra \u00d3ptica<\/a>.<\/li>\n<li><a href=\"https:\/\/www.thefoa.org\/tech\/ref\/OSP_Construction\/Underground_Installation.html\" rel=\"nofollow noopener\" target=\"_blank\">Fiber Optic Association: Underground Cable Installation, Blowing and Jetting<\/a>.<\/li>\n<li><a href=\"https:\/\/conduitcalc.plasticpipe.org\/pdf\/tn-50-guide-to-specifying-hdpe-conduit.pdf\" rel=\"nofollow noopener\" target=\"_blank\">Plastics Pipe Institute: Guide to Specifying HDPE Conduit, 2019 edition<\/a>.<\/li>\n<\/ul>\n<h2>Resumen<\/h2>\n<p>A microduct route works when the cable, usable bore, joints and installation equipment are selected together. Check the entire path before installation, keep test conditions separate from operating limits, and plan spare channels around real destinations and future cables. That preparation makes phased expansion practical and reduces avoidable installation problems.<\/p>\n<p>Review ANMASPC&#8217;s <a href=\"https:\/\/microductconnector.com\/product\/hdpe-3-ways-1210mm-with-pe-3-4mm-direct-buried-db-series-micro-duct-for-telecom-air-blown-cable-underground-installation-project-product\/\">three-way 12\/10 mm HDPE microduct bundle<\/a> and contact the team with your proposed cable, route and installation method to confirm the relevant configuration and documents.<\/p>\n<\/article>","protected":false},"excerpt":{"rendered":"<p>Asegure la compatibilidad del cable de fibra para microconductos con el di\u00e1metro interior del conducto, los conectores y el equipo de soplado. Conozca qu\u00e9 limita la distancia de instalaci\u00f3n y c\u00f3mo reservar canales para el crecimiento de la red.<\/p>","protected":false},"author":2,"featured_media":5437,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[21],"tags":[],"class_list":["post-5453","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-insights"],"_links":{"self":[{"href":"https:\/\/microductconnector.com\/es\/wp-json\/wp\/v2\/posts\/5453","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/microductconnector.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/microductconnector.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/es\/wp-json\/wp\/v2\/comments?post=5453"}],"version-history":[{"count":1,"href":"https:\/\/microductconnector.com\/es\/wp-json\/wp\/v2\/posts\/5453\/revisions"}],"predecessor-version":[{"id":5454,"href":"https:\/\/microductconnector.com\/es\/wp-json\/wp\/v2\/posts\/5453\/revisions\/5454"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/microductconnector.com\/es\/wp-json\/wp\/v2\/media\/5437"}],"wp:attachment":[{"href":"https:\/\/microductconnector.com\/es\/wp-json\/wp\/v2\/media?parent=5453"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/microductconnector.com\/es\/wp-json\/wp\/v2\/categories?post=5453"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/microductconnector.com\/es\/wp-json\/wp\/v2\/tags?post=5453"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}